• Title/Summary/Keyword: Air quality standards

Search Result 255, Processing Time 0.024 seconds

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사 (The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation)

  • 전정인;이혜원;최현진;전형진;이철민
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

SO2, NO2 and BTEX Concentrations in Educational and Industrial Areas: Field Measurements in Kuwait

  • Al-Awadhi, Jasem M.
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.169-178
    • /
    • 2016
  • Measurements of $SO_2$, $NO_2$ and benzene, toluene, ethylbenzene, and xylenes BTEX concentrations using passive tubes were carried out at five locations featuring educational and light industrial activities in south western Kuwait City during 2014. The five selected sites, chosen to be statistically representative of land use in the study area, were monitored to evaluate the impacts of traffic and light industrial activities on pollutant concentrations. The recorded mean concentrations of $NO_2$, $SO_2$ and BTEX were 40.3, 28.1 and $3.72{\mu}g/m^3$, respectively. The lowest concentrations were recorded in the educational area. Comparisons between the measured concentrations and the applicable air quality standards from the Kuwait Environment Public Authority showed that the gas concentrations were lower than the allowable limits.

한국과 중국의 콘크리트용 화학 혼화제 품질 규정 비교 (Comparison of Quality Standards of Chemical Admixtures for Concrete between Korea and China)

  • 후윈야오;임군수;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.97-98
    • /
    • 2023
  • In this study, comparison of the quality standard of chemical admixtures between Korea and China is conducted. It is classified into three types of water reducing agents: standard, delayed, and accelerated according to the sensitivity and strength improvement of the sensitivity and strength of the agent. However, Chinese standards classify reducing agents only as standard, high efficiency, and high performance, and do not add AE agents into water reducing agent. On the other hand, that of Korea has a classification regulation for reducing agents added with AE agents.

  • PDF

알데하이드 악취물질의 인증표준물질 개발 (Development of certified reference materials for odorous aldehyde)

  • 김용두;우진춘;배현길;김병문;이병길;허귀석
    • 분석과학
    • /
    • 제21권1호
    • /
    • pp.14-19
    • /
    • 2008
  • 많은 악취물질 중에 알데하이드는 인간의 호흡기 자극을 유발할 뿐만 아니라 인간의 건강에 상당히 안좋은 영향을 미친다. 알데하이드류의 악취물질은 일반 대기오염물질과 달리 ppt 수준의 매우 극미량에서 악취를 발생하는 성분이 많아 매우 극미량의 측정기술의 필요하다. 또한 대부분 반응성이 크고 안정성이 낮아 표준가스 제조 및 분석이 매우 어려워 정확한 측정이 어렵다. $10{\mu}mol/mol$ 수준의 농도로 제조된 4성분 알데하이드 CRM(MK0731)은 ISO 6142에 의한 중량법으로 제조하였다. $10{\mu}mol/mol$ 알데하이드 표준가스 실린더를 반복 제조하여 각각 GC-FID로 제조의 균질성을 조사하였고, 개발된 알데하이드류 CRM 인증값의 상대 확장불확도는 2.11 %(95%의 신뢰수준, k=2)로 조사되었다.

기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구 (A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board)

  • 김혜정;송규동;이윤규
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

국내 시간별 대기환경지수 방법의 문제점과 개선 방안 (Korean HAEI Method-a Critical Evaluation and Suggestions)

  • 백성옥;이여진;박대권
    • 한국대기환경학회지
    • /
    • 제22권4호
    • /
    • pp.518-528
    • /
    • 2006
  • The air quality index (AQI) is an index for reporting daily or hourly air quality to the general public. The AQI focuses on health effects that can happen within a few hours or days after breathing polluted air. Many countries have their own AQI reporting systems, and the HAEI (hourly air environment index) method is now being used in Korea. In this study, in order to compare the AQI results from different methods, we applied three methods. i.e. US AQI, Canadian AQI, and Korean HAEI, to the same air quality data-base. The data-base was constructed from 10 monitoring sites in Gyeong-buk province for the last four years since 2000. Based on the results, a critical evaluation of the Korean HAEI method was made, and a number of suggestions and recommendations were presented to improve the AQI reporting system in Korea.

실내공기질 공정시험방법과 기준의 동시 개정에 따른 접착제 제품의 TVOC 관리수준 평가 (The TVOC management level evaluation of adhesive product following to simultaneous revision of indoor air quality testing methods and standards)

  • 유지호;박준만;김만구
    • 분석과학
    • /
    • 제23권3호
    • /
    • pp.255-260
    • /
    • 2010
  • 환경부에서는 오염물질 다량 방출 건축자재의 효율적인 관리를 위해 "다중이용시설 등의 실내 공기질 관리법" 중 접착제의 시험방법과 방출관리기준을 동시에 개정하였다. 따라서 기존 관리수준과 개정 관리수준의 직접적인 비교가 불가능하다. 이 연구에서는 접착제의 개정된 시험방법의 각 요소들이 오염물질 방출강도에 미치는 영향들을 기존 시험방법과 비교하여 검토하였다. 이를 통하여 개정된 오염물질 방출관리기준을 평가하였다. 그 결과 접착제는 시험기간의 변경으로 인해 방출강도가 약 2.5배 약화되었고 건조시간의 변경에 따른 방출강도의 차이는 거의 없는 것으로 나타났다. 시험방법의 변경된 내용을 적용한 TVOC 방출 관리기준은 기존 방출 관리기준에 비해 약 2.1배 강화된 것으로 나타났다.

다양한 호흡기 보호용 면체 마스크의 서브 마이크론 입자에 대한 여과 성능 평가 (Filtration Performance Evaluation of Various Respiratory Face Masks Against Sub-Micron Particles)

  • ;조희주;박현설
    • 한국입자에어로졸학회지
    • /
    • 제19권1호
    • /
    • pp.1-11
    • /
    • 2023
  • Respiratory face masks are protective facepieces that are designed to filter inhaled air. They are easy-to-use devices that can protect the wearer against various hazardous particles in the air. Respiratory face masks also prevent the spread of viruses and bacteria-containing droplets that are released from the coughing or sneezing of the infected people. During the COVID-19 pandemic, various types of face masks have circulated on the market. Their ability to filter sub-micron particles, which are the sizes of harmful particulate matter and airborne viruses, needs to be investigated. Their breathability, the easiness of breath through the mask, also needs to be considered. In this study, wwe evaluated the performance of filters used for different types of face masks certified by different standards including Korean (KF94, KF80, KF-AD), USA (N95), and Chinese (KN95) standards. We also tested the filters of nanofiber masks and surgical masks for which there are no standards for filtration test. The N95 mask filters showed the highest quality factor for capturing virus-sized particles. The other types of mask filters have acceptable performance except for nanofiber mask filters whose performance is very low.

공동주택내 이산화질소(NO2) 및 휘발성유기화합물(VOCs) 노출에 따른 건강 위해성 평가 (Health Risk Assessment by Potential Exposure of NO2 and VOCs in Apartments)

  • 정순원;양원호;손부순
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.242-249
    • /
    • 2007
  • Indoor air quality has become a topic of interest and concern. Especially changes in construction design and the increased use of synthetic products may result in an increasing of complaints and health effects about the quality of indoor air at home. In this study, nitrogen dioxide($NO_2$) and volatile organic compounds(VOCs) within new and established apartments on the basis of 4 years of building year were measured every 3 days consecutively during 60 days. We selected each 10 house in Seoul, Asan and Daegu, respectively, and produced risk numbers for hazard quotients, and predicted increases in incidence of cancer. The calculations were made for the adult with default exposure values and also made for a worst case scenario using Monte-Carlo simulation as describing the reasonable exposure(RME). Mean of Monte carlo analysis by benzene, in the construction under 4 years (male: $9.2{\times}10^{-5}$, female: $1.0{\times}10^{-4}$) and over 4 years (male: $6.8{\times}10^{-5}$, female: $8.3{\times}10^{-5}$) exceeded $10^{-6}$ of permitted standards in US EPA, RME of Monte carlo analysis. In construction under 4 yews (male: $9.9{\times}10^{-3}$, female: $9.6{\times}10^{-3}$) and over 4 years (male: $9.8{\times}10^{-3}$, female: $7.8{\times}10^{-3}$) exceeded $10^{-4}$ of maximum permitted standards in US EPA. The hazard index of non-carcinogenic pollutants by nitrogen dioxide, toluene, m,p-xylene and o-xylene, both male and female in apartment constructed under 4 yews and over 4 years was found less than the permitted standards of hazardous health effects in CTE. Significant cancer risks and non-cancer hazard quotients were predicted in under 4 yews of building year.