• 제목/요약/키워드: Air quality standards

검색결과 255건 처리시간 0.023초

신축아파트 환기방식에 따른 실내공기질 변화와 이에 대한 시뮬레이션 및 건강 위해성 평가 (Simulation and Health Risk Evaluation of Indoor Air Quality Changes by Ventilation System in New Apartment)

  • 포위;정재연;정인수
    • 한국농촌건축학회논문집
    • /
    • 제23권4호
    • /
    • pp.38-45
    • /
    • 2021
  • In this study, air quality conditions were identified and analyzed in real time, at the same time, living habits and ventilation methods were maintained in the daily life of residents, and thus, this present study focuses on the lifestyles of residents. Previous studies showed a difference from this study, focusing on the study on the effects of changes in indoor air quality on human health according to the indoor air quality process test standards of the Ministry of Environment. Formaldehyde concentrations exceeded all ventilation standards, but satisfied the organic standards of the Ministry of Environment when ventilation devices and air purifiers were activated. As such, it was investigated that a large amount of formaldehyde emission in the condo is initially ventilated, but a certain concentration is maintained. The change in PM2.5 concentration according to the ventilation method showed a clear difference. As a result of simulating indoor air flow during natural ventilation, the effects of wind speed and wind direction affect the flow rate of indoor air, and indoor polluted air is stagnant even in the presence of wind and is not completely discharged. When the risk assessment results are averaged on the day of measurement, the trends of change between adults and children are almost equivalent, but the results address that children are more sensitive to risk than adults.

Air Quality Changes in a Museum Damaged by a Tsunami - Whale and Sea Museum, Iwate, Japan -

  • MATSUI, Toshiya;KAWASAKI, Emi;Huttmann, Imme
    • 보존과학회지
    • /
    • 제35권1호
    • /
    • pp.51-60
    • /
    • 2019
  • This paper provides quantitative data that describes the evolution of the air quality in the Whale and Sea Museum, located in the Iwate prefecture, collected after the 2011 Great East Japan Earthquake and tsunami. The museum was damaged significantly by the disaster, and restoration works continued for over six years. The air quality in the temporary storage facility and museum was monitored during the rehabilitation process. Evaluation of air quality is carried out by gas chromatography- mass spectrometry, ion chromatography and high-performance liquid chromatography. The results showed that the characteristics of the chemical components differed depending on the measurement locations inside the building. The museum atmosphere tended to be alkaline as the airtightness increased because of the maintenance works at the entrance. It was also determined that it was necessary to study the intake/exhaust routes and to clean them according to the contamination degree. In Japan, there are recommended museum air quality standards for acetic acid, formic acid, alkali, and aldehydes. The results indicated that these standards should not be used as a reference for damaged museums. Furthermore, at the temporary storage facilities for to store the collections during the rehabilitation of the museum, solvents such as ethyl benzene, toluene, and xylene are initially abundant, although they can be reduced by ventilation, while other components such as 2E1H was confirmed in this case are likely to remain.

미국의 환기 기준 동향 (Ventilation standards in USA)

  • 배귀남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.116-118
    • /
    • 2005
  • The ASHRAE first ventilation standard was established in 1973. This standard has been revised regularly, and recently the ventilation standard for residential building was issued separately. Two ASHRAE ventilation standards are introduced in this article.

  • PDF

室內空氣質 硏究의 現況과 展望 (Present and Future Perspectives of Studies on Indoor Air Quality)

  • 김윤신
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.371-383
    • /
    • 1999
  • This paper discusses the importance of indoor air quality based on literaure review of domestic and foreign studies. A number of international efforts to propose standards and guidelines for indoor environmental quality are also reviewed. The pattern of major studies on indoor air quality focussed on characterizaton of gaseous pollutants, particulates, and other specific pollutants during the past decades, whereas VOCs, specific carcinogen, and microbiological agents might be good target pollutants to investigate the effects of human health in recent years. Management of indoor air quality requires a different approach than that adopted for outdoor air. Adequate ventilation of the indoor environment is essential, and a balance between energy conservation and the need for good air quality is required. The ways for managing indoor air quality that will be of great importance are discussed a role of control policy for guidance on how to achieve good indoor air quality.

  • PDF

인체의 위해성과 수생태계를 고려한 수질환경기준 설정에 관한 연구 (A Study on Water Quality Standard for the Protection of Human Health and Aquatic Life)

  • 이재현;김윤신
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.985-992
    • /
    • 2007
  • There are about 40,000 chemicals used in Korea and 300 new types of chemicals are added to the list every year, influencing quality of air, soil and water. Water quality standards that serve as the basis for water quality management have been proved inefficient and insufficient compared to those of advanced countries. This study aims to improve the existing water quality standards. Most importantly, the water quality standards need to take into account not only protection of human health but also aquatic resources. To that end, water quality criteria need to be set by monitoring each watershed every year and conducting risk assessment. Criteria for human health are set at $10^{-6}$ cancer risk level, and for aquatic life at conservative level, adopting the methodology of the U.S. and Australia, respectively. After carrying out technical and economic feasibility studies, more conservative criteria will be used to decide final water quality standards. The development of this system to establish integrated water quality standards for both human health and aquatic resources protection is urgently needed.

우리나라, 미국 및 유럽의 대기환경기준 강도에 관한 비교 연구 (A Comparative Study on the Ambient Air Quality Standard Strength among Korea, the U.S.A. and the EU)

  • 박민빈;이태정;이은선;김동술
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.559-574
    • /
    • 2016
  • Based on air quality monitoring data ('10~'14) of Suwon City provided by the Korean Department of Environment, a fundamental statistic for 5 criteria pollutants such as $SO_2$, CO, $NO_2$, $O_3$, and $PM_{10}$ was initially investigated. The purpose of this paper was to review the ambient air quality standards(AAQS) of Korea, the U.S.A. and the EU and further to assess the degree of standard strength by the achievability of the AAQS comparing each national standard. Since the level and the way of standards for each air pollutant are various among countries, it is difficult to determine the degree of relative attainment using the same set of data above. Further when all the areas having bad air quality for a specific pollutant are classified as non-attainment case, it is more difficult to assess the degree of standard strength. Thus we introduced a new concept called the average concentration distance (ACD) to quantitatively estimate the strength. As results, the Korean 1-hr $NO_2$ AAQS is slightly stronger than the US standard and weaker than the EU standard. The Korean $O_3$ standard is strongest; however, the Korean $PM_{10}$ standard is weakest. Furthermore the equivalent levels of 8-hr $O_3$ standards in the U.S.A. and the EU were respectively estimated as 97.5 and 95.7 percentiles of the Korean standard with maintaining the existing standard of 60 ppb.

실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과 (The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots)

  • 박정호
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구 (A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.

대기오염측정망 정도관리의 문제점과 개선방향 (Problems and Improvements in the Quality Control of the Air Monitoring Network)

  • 김덕승;박정호
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.