• Title/Summary/Keyword: Air quality control region

Search Result 34, Processing Time 0.029 seconds

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

A Regional Source-Receptor Analysis for Air Pollutants in Seoul Metropolitan Area (수도권지역에서의 권역간 대기오염물질 상호영향 연구)

  • Lee, Yong-Mi;Hong, Sung-Chul;Yoo, Chul;Kim, Jeong-Soo;Hong, Ji-Hyung;Park, Il-Su
    • Journal of Environmental Science International
    • /
    • v.19 no.5
    • /
    • pp.591-605
    • /
    • 2010
  • This study were to simulate major criteria air pollutants and estimate regional source-receptor relationship using air quality prediction model (TAPM ; The Air Pollution Model) in the Seoul Metropolitan area. Source-receptor relationship was estimated by contribution of each region to other regions and region itself through dividing the Seoul metropolitan area into five regions. According to administrative boundary, region I and region II were Seoul and Incheon in order. Gyeonggi was divided into three regions by directions like southern(region III), northern(IV) and eastern(V) area. Gridded emissions ($1km{\times}1km$) by Clean Air Pollicy Support System (CAPSS) of National Institute of Environmental Research (NIER) was prepared for TAPM simulation. The operational weather prediction system, Regional Data Assimilation and Prediction System (RDAPS) operated by the Korean Meteorology Administration (KMA) was used for the regional weather forecasting with 30km grid resolution. Modeling period was 5 continuous days for each season with non-precipitation. The results showed that region I was the most air-polluted area and it was 3~4 times more polluted region than other regions for $NO_2$, $SO_2$ and PM10. Contributions of $SO_2$ $NO_2$ and PM10 to region I, II and III were more than 50 percent for their own sources. However region IV and V were mostly affected by sources of region I, II and III. When emissions of all regions were assumed to reduce 10 and 20 percent separately, air pollution of each region was reduced linearly and the contributions of reduction scenario were similar to those of base case. As input emissions were reduced according to different ratio - region I 40 percent, region II and III 20 percent, region IV and V 10 percent, air pollutions of region I and III were decreased remarkably. The contributions to region I, II, III were also reduced for their own sources. However, region I, II and III affected more regions IV and V. Shortly, graded reduction of emission could be more effective to control air pollution in emission imbalanced area.

PM2.5 Source Apportionment Analysis to Investigate Contributions of the Major Source Areas in the Southeastern Region of South Korea (동남지역 주요 배출지역의 PM2.5 기여도 분석)

  • Ju, Hyeji;Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol;Yoo, Chul;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.517-533
    • /
    • 2018
  • We utilize the CAMx (Comprehensive Air Quality Model with eXtensions) system and the PSAT (Particulate Source Apportionment Technology) diagnostic tool to determine the $PM_{2.5}$ concentration and to perform its source apportionment in the southeastern region of South Korea. For a year-long simulation, eight local authorities in the region such as Pohang, Daegu, Gyeongju, Ulsan, Busan-Gimhae, Gosung-Changwon, Hadong, and all remaining areas in Gyeongsangnam-do, are selected as source areas based on the emission rates of $NO_x$, $SO_x$, VOC, and primary PM in CAPSS (Clean Air Policy Support System) 2013 emissions inventory. The CAMx-PSAT simulation shows that Pohang has the highest $PM_{2.5}$ self-contribution rate (25%), followed by Hadong (15%) and Busan-Gimhae (14%). With the exception of Pohang, which has intense fugitive dust emissions, other authorities are strongly affected by emissions from their neighboring areas. This may be measured as much as 1 to 2 times higher than that of the self-contribution rate. Based on these estimations, we conclude that the efficiency of emission reduction measures to mitigate $PM_{2.5}$ concentrations in the southeastern region of South Korea can be maximized when the efforts of local or regional emission controls are combined with those from neighboring regions. A comprehensive control policy planning based on the collaboration between neighboring jurisdictional boundaries is required.

Aerodynamic Resistance and Eddy Diffusivity above the Plug Stand under Artificial Light (인공광하에서 공정묘 개체군상의 공기역학적 저항 및 확산계수)

  • 김용현;고재풍수
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.152-159
    • /
    • 1996
  • Experiment was performed in a newly developed wind tunnel with light system to determine the aerodynamic resistance and eddy diffusivity above the plug stand under artificial light. Maximum air temperature appeared near the top of the plug stand under artificial light. Since Richardson number was ranged from -0.07 to +0.01, the atmosphere above the plug stand in wind tunnel was in an unstable or near- neutral stability state. The average aerodynamic resistance at rear region of plug stand was 25 % higher than that at middle region. Eddy diffusivity($K_{M}$) linearly increased with the increasing air current speed. $K_{M}$ at air current speed of 0.9 m.$s^{-1}$ was about two times as many as that at air current speed of 0.3 m.$s^{-1}$. And average $K_{M}$ at the rear region was 15% lower than that at the middle region. These results indicated that the diffusion of heat and mass along the direction of air current inside the plug stand was different. It might cause the lack of uniformity in the growth and quality of plug seedlings. The wind tunnel developed in this study would be useful to investigate the effects of air current speed on microclimates and the growth of plug seedlings under artificial light in a semi- closed ecosystem.

  • PDF

Indoor Air Quality in Elementary School Children's Homes in Ulsan: Comparison between Groups with and without Allergic Rhinitis (울산지역 초등학생 가정의 실내공기질: 알레르기 비염 환아군과 대조군 비교)

  • Lee, Chi-Hyeon;Lee, Byeong-Kyu;Oh, In-Bo;Lee, Ji-Ho;Sim, Chang-Sun;Kim, Yang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.365-373
    • /
    • 2012
  • This study compared indoor air quality of homes in which elementary school children with and without (case and control) allergic rhinitis live in the Ulsan metropolitan region (UMR). A total of 58 homes (case and control: 29, respectively; children aged 7 to 12 years) was selected for indoor air quality measurements. The concentrations of all general indoor air pollutants, except $PM_{2.5}$, in the case group were much higher than those in the control group. In particular, the average concentrations of $O_3$ and $NO_2$ in the case group were statistically significantly (p<0.05) higher than those in the control group. Average concentrations of $CO_2$ in the case and control groups and $NO_2$ in the case group exceeded the standard level. Some components of aldehydes and ketones and VOCs indicated large difference of average concentrations between two groups, but there were no statistically significant differences.

Temporal and Spatial Variation and Characteristics of Ambient Air Quality in Urban Areas in Gyeonggi Province (경기도 도시지역 환경대기질의 시공간적 추이와 특성)

  • Kim, Jong-Chan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Objectives: The purpose of this study was to provide policy directions for air pollution reduction by analyzing the variation in the characteristics of air contaminants around the Gyeonggi Province area. Methods: The data used in the study was obtained from air quality monitoring stations operated by the Gyeonggi Provincial Government. The target area was the air quality management area of the Gyeonggi Province region. Results: The concentration of $PM_{10}$ (particles measuring $10{\mu}m$ or less) in 2009 was $60{\mu}g/m^3$, which has been reduced by about 2.7% per year after improvement countermeasures were emplaced. The air pollution control policy was especially more effective for coarse particulate matter (CPM, $PM_{10-2.5}$). The improvement of $NO_2$ pollution was generally very low, especially in cities which had considerable automobile traffic. The concentration of $SO_2$ pollution was rapidly improved in industrial areas, but did not show any difference for multiple and general cities. The predicted concentration of $PM_{10}$ for 2014 based on the trend over 2001-2009 was $53.4{\mu}g/m^3$, which fails to meet the target concentration of $40{\mu}g/m^3$. The predicted concentration of $NO_2$ shows a very low probability of achieving the target concentration of 22 ppb, and thus the current improvement of air quality has proven unsatisfactory. Conclusion: Air pollution control policy should be enforced according to regional pollution characteristics in order to obtain maximum effectiveness in improvement.

환경보전 정책에 관한 제 방법의 상대적 효율성 연구 - 판매가능한 배출허용권제도를 중심으로 -

  • Lee, Seon;No, Gong-Gyun;Lee, Jae-Geun
    • Environmental and Resource Economics Review
    • /
    • v.1 no.1
    • /
    • pp.115-149
    • /
    • 1991
  • In evaluating current environmental protection policy, economists often note that current regulations are more costly than necessary to meet environmental quality standards. While the a priori case can be made that current regulatory approaches entail higher-than-necessary costs to attain environmental standards, there is relatively little empirical evidence to support this claim in Korea. The purpose of this analysis is to supply some of the missing evidence by presenting the results of one study that assesses some of the potential savings associated with implementing economic, rather than command-and-control regulatory approaches to abate one type of air pollution in one region, in Korea, Specifically, the analysis examine the costs of meeting a long-term standard for TSP under the alternative control strategies for stationary sources of TSP in Ulsan Industrial Complex region. The alternative strategies that are considered are current command-and-control and various marketable permit designs. The analysis shows that the most efficient policy of emissions control is economic approaches, supporting results of previous empirical studies conducted in other countries.

  • PDF

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

Long-term Trend Analysis of Key Criteria Air Pollutants over Air Quality Control Regions in South Korea using Observation Data and Air Quality Simulation (관측자료와 대기질 모사를 이용한 주요 기준성 대기오염물질의 권역별 장기변화 분석)

  • Ju, Hyeji;Kim, Hyun Cheol;Kim, Byeong-Uk;Ghim, Young Sung;Shin, Hye Jung;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.101-119
    • /
    • 2018
  • In this study, we analyzed long-term measurements and air quality simulation results of four criteria air pollutants ($PM_{10}$, $O_3$, $NO_2$, and $SO_2$) for 10 years, from 2006 to 2015, with emphasis on trends of annual variabilities. With the observation data, we conducted spatial interpolation using the Kriging method to estimate spatial distribution of pollutant concentrations. We also performed air quality simulations using the CMAQ model to consider the nonlinearity of the secondary air pollutants such as $O_3$ and the influence of long-range transport. In addition, these simulations are used to deduce the effect of long-term meteorological variations on trends of air quality changes because we fixed the emissions inventory while changing meteorological inputs. The nation-wide inter-annual variability of modeled $PM_{10}$ concentrations was $-0.11{\mu}g/m^3/yr$, while that of observed concentrations was $-0.84{\mu}g/m^3/yr$. For the Seoul Metropolitan Area, the inter-annual variability of observed $PM_{10}$ concentrations was $-1.64{\mu}g/m^3/yr$ that is two times rapid improvement compared to other regions. On the other hand, the inter-annual variability of observed $O_3$ concentrations is 0.62 ppb/yr which is larger than the simulated result of 0.13 ppb/yr. Magnitudes of differences between the modeled and observed inter-annual variabilities indicated that decreasing trend of $PM_{10}$ and increasing trend of $O_3$ are more influenced by emissions and oxidation states than meteorological conditions. We also found similar patterns in $NO_2$. However, $NO_2$ trends showed greater regional and seasonal differences than other pollutants. The analytic approach used in this study can be applicable to estimate changes in factors determining air quality such as emissions, weather, and surrounding conditions over a long term. Then analysis results can be used as important data for air quality management planning and evaluation of the chronic impact of air quality.

Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas (중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교)

  • Lee, Yong-Ki;Kim, Woong-Soo;Hong, Soon-Mo;Shin, Eun-Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.