• Title/Summary/Keyword: Air quality control

Search Result 927, Processing Time 0.033 seconds

Impacts of Carbon Neutrality and Air Quality Control on Near-term Climate Change in East Asia (탄소중립과 대기질 개선 정책이 동아시아 근 미래 기후변화에 미치는 영향)

  • Youn-Ah Kim;Jung Choi;Seok-Woo Son
    • Atmosphere
    • /
    • v.33 no.5
    • /
    • pp.505-517
    • /
    • 2023
  • This study investigates the impacts of carbon neutrality and air quality control policies on near-term climate change in East Asia, by examining three Shared Socioeconomic Pathways (SSPs) scenarios from five climate models. Specifically, low carbon and strong air quality control scenario (SSP1-1.9), high carbon and weak air quality control scenario (SSP3-7.0), and high carbon and strong air quality control scenario (SSP3-7.0-lowNTCF) are compared. For these scenarios, the near-term climate (2045-2054 average) changes are evaluated for surface air temperature (SAT), hot temperature extreme intensity (TXx), and hot temperature extreme frequency (TX90p). In all three scenarios, SAT, TXx, and TX90p are projected to increase in East Asia, while carbon neutrality reduces the increasing rate of SAT and hot temperature extremes. Air quality control strengthens the warming rate. These opposed mitigation effects are robustly forced in all model simulations. Nonetheless, the impact of carbon neutrality overcomes the impact of air quality control. These results suggest that fast carbon neutrality, more effective than an air quality control policy, is necessary to slowdown future warming trend in East Asia.

Management Policy and Control Technology for Indoor Air Quality in Korea (국내 실내공기질 관리정책의 변천 및 제어기술의 현황)

  • Bae, Gwi-Nam;Ji, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.378-389
    • /
    • 2013
  • In Korea, studies on the indoor air quality have been conducted since mid of 1980s. The turning point occurred in 2003 by establishing the act of the indoor air quality management for public facilities. According to the law, the basic plan for indoor air quality management is prepared by government every five years, affecting greatly governmental policy and related academia and industries. Indoor air quality survey was mostly carried out among indoor air quality researches. After then, assessment of health effect and air cleaning technology were studied. Although various control technologies for particle, bioaerosol, odor, and hazardous chemicals have been applied to indoor environments, breakthrough technologies are needed to solve real problems facing at the applied environments. In the future, issue of indoor air quality is more interested and both management policy and control technology are key factors in order to realize comfort and healthy indoor environments.

A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom (학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구)

  • Park, Hwan-Chul;Lee, Dong-Hyeon;Yee, Jurng-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System (실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교)

  • Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

Methodology of Application to Air Quality Model to Evaluate the Results of the Enforcement Plan in Seoul Metropolitan Area (수도권 지역의 대기환경관리 시행계획 추진결과 평가를 위한 대기질 모델링 적용 방법)

  • Yoo, Chul;Lee, Dae-Gyun;Lee, Yong-Mi;Lee, Mi-Hyang;Hong, Ji-Hyung;Lee, Seok-Jo
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1647-1661
    • /
    • 2011
  • The Government had devised legislation of Special Act and drew up guidelines for improving air quality in Seoul Metropolitan area. In 2007 local government of Seoul, Incheon and Gyeonggi conducted the results of application policy by reduced air pollutants emission for the first time. Although there was reduction of air pollutant emission in each local government, it was ineffective as expected using air pollution monitoring database. Therefore we worked out a way to prepare modeling input data using the results of enforcement plan. And we simulated surface $NO_2$ and PM10 before and after decrease in air pollutants emission and examine reduction effects of air pollution according to enforcement regulation except other influence, by using MM5-SMOKE-CMAQ system. Each local government calculated the amount of emission reduction under application policy, and we developed to prepare input data so as to apply to SMOKE system using emission reduction of enforcement plan. Distribution factor of emission reduction were classified into detailed source and fuel codes using code mapping method in order to allocate the decreased emission. The code mapping method also included a way to allocate spatial distribution by CAPSS distribution. According to predicted result using the reduction of NOx emission, $NO_2$ concentration was decreased from 19.1 ppb to 18.0 ppb in Seoul. In Gyeonggi and Incheon $NO^2$ concentrations were down to 0.65 ppb and 0.68 ppb after application of enforcement plan. PM10 concentration was reduced from 18.2 ${\mu}g/m^3$ to 17.5 ${\mu}g/m^3$ in Seoul. In Gyeonggi PM10 concentration was down to 0.51 ${\mu}g/m^3$ and in Incheon PM10 concentration was decreased about 0.47 ${\mu}g/m^3$ which was the lower concentration than any other cities.

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

Intelligent Air Quality Sensor System with Back Propagation Neural Network in Automobile

  • Lee, Seung-Chul;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.468-471
    • /
    • 2005
  • The Air Quality Sensor(AQS), located near the fresh air inlet, serves to reduce the amount of pollution entering the vehicle cabin through the HVAC(heating, ventilating, and air conditioning) system by sending a signal to close the fresh air inlet door/ventilation flap when the vehicle enters a high pollution area. One chip sensor module which include above two sensing elements, humidity sensor and bad odor sensor was developed for AQS (air quality sensor) in automobile. With this sensor module, PIC microcontroller was designed with back propagation neural network to reduce detecting error when the motor vehicles pass through the dense fog area. The signal from neural network was modified to control the inlet of automobile and display the result or alarm the situation. One chip microcontroller, Atmega128L (ATmega Ltd., USA) was used. For the control and display. And our developed system can intelligently detect the bad odor when the motor vehicles pass through the polluted air zone such as cattle farm.

  • PDF

Review on the Current Status and Policy on PM2.5 in China (중국 초미세먼지 현황 및 정책 동향)

  • Moon, Kwang-Joo;Cheo, Hyeok-gi;Jeon, Kwon-ho;Yang, Xiaoyang;Meng, Fan;Kim, Dai-gon;Park, Hyun-Ju;Kim, Jeong-soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.373-392
    • /
    • 2018
  • The emission of air pollutants in China has increased rapidly as its economy expanded over the last decades. The Chinese government has recently acknowledged the seriousness of the resulting air pollution and is trying to improve air quality in many ways. Here, we review the air quality control and management policies in China, one of our closest neighbors, because these policies may also influence the air quality in Korea. This study examined the recent policies on $PM_{2.5}$ reduction and analyzed the variation in air quality and air pollutant emissions in China. The ambient air quality and emission standards in China have been strengthened, based on China's Air Pollution Prevention and Control Action Plan of 2013. As a result, the annual mean concentration of $PM_{2.5}$ in 2015 in 74 large Chinese cities declined by 23.6% compared with 2013 values. Coal consumption in China also has been reduced by more than 10% per year since 2013. Furthermore, the laws controlling atmospheric emissions were revised again in 2016, and an air pollution forecasting and warning system was implemented to help manage air pollution problems. At present, the Chinese government is trying to evaluate its policies on $PM_{2.5}$ and find a new paradigm to mitigate ongoing $PM_{2.5}$ pollution. In this context, a joint study between Korea and China has been initiated to investigate the characteristics and sources of ambient $PM_{2.5}$ and to identify factors contributing to the high $PM_{2.5}$ concentrations in northeast China. We expect that this academic collaboration will benefit both countries in their search for new policies for $PM_{2.5}$ reduction.

Comparison of the Real-time Measurements for PM2.5 and Quality Control Method (PM2.5 자동측정장비 비교 및 정도관리 방안)

  • Park, Mikyung;Park, Jin Su;Jo, Mira;Lee, Yong Hwan;Kim, Hyun Jae;Oh, Jun;Choi, Jin Soo;Ahn, Joon Young;Hong, You Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).