• Title/Summary/Keyword: Air pollution particle

Search Result 297, Processing Time 0.024 seconds

Anomalous Variations in Atmospheric Carbon Monoxide Associated with the Tsunami

  • Retnamayi, Anjali;Ganapathy, Mohan Kumar;Santha, Sreekanth Thulaseedharan
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Variations in ambient atmospheric carbon monoxide(CO) observed at an inland mining site in the Indo-Gangetic plains, Jaduguda ($22^{\circ}38'N$, $86^{\circ}21'E$, 122m MSL, ~75 km away from the coast of the Bay of Bengal) during the Tsunami of 26 December 2004 were monitored. CO mixing ratio over this site was measured using a non-dispersive infrared analyzer (Monitor Europe Model 9830 B). Back trajectory analysis data obtained using NOAA Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) Model was also used for this study. Variations in CO mixing ratio at a coastal site, Thiruvananthapuram ($8^{\circ}29'N$, $76^{\circ}57'E$, located ~2 km from the Arabian Sea coast) have also been investigated using CO data retrieved from the Measurement Of Pollution In The Troposphere (MOPITT) instrument. Ground-based measurements indicated abnormal variations in CO mixing ratio at Jaduguda from 25 December 2004 evening (previous day of the Tsunami). MOPITT CO data showed an enhancement in CO mixing ratio over Thiruvananthapuram on the Tsunami day. Back trajectory analyses over Thiruvananthapuram and Jaduguda for a period of 10 days from $21^{st}$ to $30^{th}$ December 2004 depicted that there were unusual vertical movements of air from high altitudes from 25 December 2004 evening. CO as well as the back trajectory analyses data showed that the variations in the wind regimes and consequently wind driven transport are the most probable reasons for the enhancement in CO observed at Jaduguda and Thiruvananthapuram during the Tsunami.

Relationship between PM10 and O3 concentration and allergy symptoms among residents in the Gwangyang area (광양지역의 PM10, O3농도와 거주자의 알레르기 증상과의 연관성)

  • Oh, Yujin;Choi, Jihee;Park, Heejin;Kim, Taejong;Kim, Geun-Bae;Son, Bu-Soon
    • Journal of odor and indoor environment
    • /
    • v.16 no.3
    • /
    • pp.277-286
    • /
    • 2017
  • The objectives of this study were to investigate the effects of $PM_{10}$ and $O_3$ concentration on the symptoms of allergic diseases. The questionnaire was used to determine whether or not symptoms of allergic diseases were present from September to October 2012. The air pollution concentration data used was the corresponding point CEM (continuous emission monitoring) data. The average concentration of $PM_{10}$ was $56.09{\mu}g/m^3$ in the control area, and the concentration in the exposed area was $40.44{\mu}g/m^3$. In the two areas, concentration of $O_3$ was 28.73 ppb and 28.74 ppb, respectively. The total average concentrations of $PM_{10}$ and $O_3$ were $45.66{\mu}g/m^3$ and 28.73 ppb in the Gwangyang area. The rate of asthma diagnosis was higher in the control area (9.6%) than in the exposed area (4.1%), but the rate of allergy eye disease was higher in the exposed area (23.9%) than in the control area (16.5%). There was a significant difference in the symptoms of some allergic diseases when the relative concentration of $PM_{10}$ and $O_3$ were high and low.

A Study on the Cold Startability and Emission Characteristics of LPG Vehicle According to Test Temperature (시험온도에 따른 LPG 차량의 저온 시동성 및 배출가스 배출특성 연구)

  • Lee, Min-Ho;Kim, Sung-Woo;Kim, Ki-Ho;Ha, Jong-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.6
    • /
    • pp.7-13
    • /
    • 2014
  • As the interest on the air pollution is gradually rising up at home and abroad, automotive and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward various main issues : whether PM emissions should be regulated for diesel and gasoline vehicles and whether gasoline and LPG powered vehicles can be further neglected from PM emission inventories. Finally, the greenhouse gas ($CO_2$, $CH_4$, $N_2O$) regulation has been discussed including automotive emission regulation. The greenhouse gas and emissions (PM) particle of automotive had many problem that cause of ambient pollution, health effects. This paper discussed the influence of LPG fuel on automotive cold startability and exhaust emissions gas. Also, this paper assessed emission characteristics due to the test temperature. These test temperature were performed by dividing the temperature of the test mode and the lowest local temperature in winter. Through this study, the correlation of cold startability, exhaust emission and greenhouse gas emission was analyzed.

Harmfulness of Particulate Matter in Disease Progression (미세먼지의 질병에 미치는 유해성)

  • Choi, Jong Kyu;Choi, In Soon;Cho, Kwang Keun;Lee, Seung Ho
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.191-201
    • /
    • 2020
  • As society develops rapidly, environmental pollution is becoming a greater risk factor threatening human health. One of the major causes of air pollution that affects human health is particulate matter (PM), which contains a heterogeneous mixture of different particle sizes and chemical compositions. PM is classified by size into general PM (PM10; diameter below 10 ㎛) and fine PM (PM2.5; diameter below 2.5 ㎛). PM2.5 can pass through the respiratory tract into the circulatory system and thence throughout the body. PM2.5 is known to stimulate oxidative stress and inflammatory responses to cells, promoting diseases such as asthma, chronic respiratory disease, cardiovascular disease, diabetes mellitus, and immunological disorders. Although detailed molecular mechanisms for how PM stimulates disease progression still need to be elucidated, together with national efforts to reduce PM production, significant research has been conducted that demonstrates the harmfulness of PM in disease progression through in vitro and in vivo experiments. This review focuses on the harmfulness of PM in disease progression; we also introduce a biological verification method for determining the hazards of PM.

Interference of Sulphur Dioxide on Balloon-borne Electrochemical Concentration Cell Ozone Sensors over the Mexico City Metropolitan Area

  • Kanda, Isao;Basaldud, Roberto;Horikoshi, Nobuji;Okazaki, Yukiyo;Benitez-Garcia, Sandy-Edith;Ortinez, Abraham;Benitez, Victor Ramos;Cardenas, Beatriz;Wakamatsu, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.162-174
    • /
    • 2014
  • An abnormal decrease in ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City Metropolitan Area (MCMA). Sharp drops in sensor signal around 5 km above sea level and above were observed in November 2011, and a reduction of signal over a broad range of altitude was observed in the convective boundary layer in March 2012. Circumstantial evidence indicated that $SO_2$ gas interfered with the electrochemical concentration cell (ECC) ozone sensors in the ozonesonde and that this interference was the cause of the reduced sensor signal output. The sharp drops in November 2011 were attributed to the $SO_2$ plume from Popocat$\acute{e}$petl volcano southeast of MCMA. Experiments on the response of the ECC sensor to representative atmospheric trace gases showed that only $SO_2$ could cause the observed abrupt drops in sensor signal. The vertical profile of the plume reproduced by a Lagrangian particle diffusion simulation supported this finding. A near-ground reduction in the sensor signal in March 2012 was attributed to an $SO_2$ plume from the Tula industrial complex north-west of MCMA. Before and at the time of ozonesonde launch, intermittent high $SO_2$ concentrations were recorded at ground-level monitoring stations north of MCMA. The difference between the $O_3$ concentration measured by the ozonesonde and that recorded by a UV-based $O_3$ monitor was consistent with the $SO_2$ concentration recorded by a UV-based monitor on the ground. The vertical profiles of the plumes estimated by Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in MCMA revealed that the effect Popocat$\acute{e}$petl was most likely to have occurred from June to October, whereas the effect of the industries north of MCMA, including the Tula complex, was predicted to occur throughout the year.

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

Geochemical Characteristics and Pollution Level of Heavy Metals of Asian Dust in Daejeon Area, 2007 (spring season) (2007년 봄철 대전지역에서 발생한 황사 및 대기부유물의 지구화학적 특성 및 중 금속의 오염도)

  • Lee, Pyeong-Koo;Youm, Seung-Jun;Bae, Beob-Geun
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.217-235
    • /
    • 2012
  • We evaluated the geochemical characteristics and their potential pollution of Asian Dusts in Daejeon, Korea during spring 2007. Compared with the chemical compositions of soils in source area of Asian Dust, those of aerosols in Daejeon were enriched with trace elements (ten to hundred fold), inferring that pollutants from China have affected on local environment in adjoining country such as Korea. Chemical analysis of aerosols during Asian dust showed that fine particles ($PM_{2.5}$) contained high contents of trace elements such as Cr, Cu, Pb, Zn, V, S, As, Cd, Co, Ni, Mo, Sb, Cs, Rb, Th, Sc and Y. In the case of TSP (Total Suspended Particle), Zr, Sr, Ba, Li, Th and U were contained much more than other trace elements. The contents of some elements (i.e. Li, Cs, Co, U, Cr, Ni, Rb, V, Th, Y, Sr and Sc) in aerosols collected in Asian Dust period, which are not likely enriched by air pollutants, were higher (2 - 4.2 fold) than those in Non Asian Dust period, indicating that these elements could be used as indicator elements for determining the occurrence of Asian Dust phenomena (especially, Sr, V, Cr & Li). In the case of Asian Dust coming through the big cities and/or industrial areas of China, the domestic aerosols had higher contents of trace elements (such as S, Cd, Zn, Pb, Cu, Mo and As) than those from Northeastern China via North Korea, indicating that the transportation courses of air mass are very important to determine the pollution degrees. Using the enrichment factors of trace elements in aerosols during Asian Dust and Non Asian Dust, we identified that some elements (i.e. S, Zn, Cu, Pb, As, Mo and Cd) were most problematic in terms of environmental hazard aspects, and these elements could affect adverse effects on human health as well as ecosystem and surface environment (soil and water) through long-lived precipitation.

Chemical Characteristics and Particle Size Distribution of PM10 in Iron and Steel Industrial Complex (포항철강공단 미세먼지(PM10)의 입경분포 및 화학적 특성)

  • Jung, Jong-Hyeon;Lee, Hyung-Don;Jeon, Soo-Bin;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5601-5609
    • /
    • 2012
  • The fine particulate matter($PM_{10}$) concentrations and contents were measured to check the health and environment influential factors in Pohang Iron and Steel Industrial Complex and its vicinities. In addition, the $PM_{10}$ distribution for each year and season was surveyed using the regional air quality monitoring stations. The measuring on the $PM_{10}$ inside the industrial complex showed $61.3{\pm}12.1{\mu}g/m^3$ for average concentration of $PM_{10}$ which was measured by Dongil Industry and $44.3{\pm}8.1{\mu}g/m^3$ measured by steel manufacturing industry complex management office. Both of them satisfied the environmental air quality standard. The percentage of $SO_4{^2}$, $NO_3{^-}$, $NH_4{^+}$ which are the secondary ions created out of the $PM_{10}$ in Dongil Industry and steel manufacturing industry complex management office was checked and it was revealed that the percentage of ${SO_4}^{2-}$ was high and it is considered that the pollution source related with the sulfides exist at the industrial complex. They were in order of ${SO_4}^{2-}$ > $Cl^-$ > $NO_3{^-}$ > $F^-$ > $NH_4{^+}$ in Dongil Industry and ${SO_4}^{2-}$ > $Cl^-$ > $NO_3{^-}$ > $NH_4{^+}$ > $F^-$ in steel manufacturing industry complex management office.

Inter-comparison of Two Aethalometers for Aerosol Black Carbon Measurements (대기 에어로졸 검댕입자 측정을 위한 두 aethalometer의 상호비교)

  • Jung, Jung-Hoon;Park, Seung-Shik;Yoon, Kwan-Hoon;Cho, Sung-Yong;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • Recently, a real-time, pocket-sized aethalometer (microAeth$^{(R)}$ model AE51) has been developed by Magee Scientific Inc. for measuring the concentration of black carbon in the atmosphere. In this study, two aethalometers, models AE-16 and AE-51, which measure the optical absorption of carbon particles at infrared 880 nm, were operated at time interval of 5-min between January 9 and February 10, 2010 at an urban site of Gwangju, to compare the accuracy of black carbon (BC) concentrations reported from the AE-51 model and to investigate reasonable sampling time of filter media in the AE-51. The air samples in the AE-51 and AE-16 models are collected on T60 (Teflon coated glass fiber) filter media (filter spot area: 0.07 $cm^2$) and quartz fiber roll-tape filter (filter spot area: 1.67 $cm^2$), respectively. Real-time measurement results indicate that when the filters were clean, the AE-51 BC was greater than or similar to the AE-16 BC data. However as the filter spots become darker, the AE-16 BC concentrations were higher than the AE-51 BC data and the difference in the BC concentrations from two AE models becomes gradually increased. Relative error in the AE-51 and AE-16 BC concentrations showed significance difference depending on used time of the filter in the AE-51 model, weather pattern, levels of air pollution, etc, ranging from 11.5% (used time of the filter in AE-51: 1,595 min) to 52.5% (used time of the filter in AE-51: 2,085 min). When considering the used time of one filter ticket in the AE-51 model and difference (or relative error %) between AE-16 and AE-51 BC concentrations, it is recommended that the standard sampling time per one filter ticket within the AE-51 model be less than approximately 24 hr (1,440 min) under the normal weather conditions except for severe haze and mist events.

A Study on the Characteristics of a Pt/TiO2 Catalyst Prepared by Liquid-Phase Ruduction for Formaldehyde Oxidation at Room Temperature (액상환원 기반 Pt/TiO2 촉매 제조를 이용한 포름알데히드 상온 산화 반응 특성 연구)

  • Jae Heon Kim;Younghee Jang;Geo Jong Kim;Sung Chul Kim;Sung Su Kim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.612-618
    • /
    • 2023
  • Modern society spends more than 80% of its daily life indoors, emphasizing the need for attention to indoor air pollution due to the improvement in living standards. In this study, the performance and reaction characteristics of the Pt/TiO2 catalysts prepared by liquid-phase reduction for the removal of formaldehyde (HCHO), one of the indoor air pollutants, at room temperature without the need for additional light or heat were investigated. As a result, it showed that catalysts prepared by the same method showed approximately 40~80% various activities depending on the type of TiO2. XRD, BET, and XPS analyses were performed to investigate the particle size, crystal structure, specific surface area, and O/Ti molar ratio of the support material, and it revealed that the correlation between the properties and performance was insignificant. To explore the oxidation reaction pathway of formaldehyde (HCHO), in situ DRIFT analysis using carbon monoxide and H2-TPR was perfomed. The results revealed that the performance was demonstrated by the oxidation state of the active metal and the adsorption-desorption characteristics of the adsorbate species.