• 제목/요약/키워드: Air permeability and thermal properties

검색결과 47건 처리시간 0.029초

Effect of Low Temperature Plasma Treatment on Wool Fabric Properties

  • Kan C. W.;Yuen C. W. M.
    • Fibers and Polymers
    • /
    • 제6권2호
    • /
    • pp.169-173
    • /
    • 2005
  • Low temperature plasma (LTP) treatment was applied to wool fabric with the use of a non-polymerizing gas, namely oxygen. After the LTP treatment, the fabric properties including low-stress mechanical properties, air permeability and thermal properties, were evaluated. The low-stress mechanical properties were evaluated by means of Kawabata Evaluation System Fabric (KES-F) revealing that the tensile, shearing, bending, compression and surface properties were altered after the LTP treatment. The changes in these properties are believed to be related closely to the inter-fiber and inter-yam frictional force induced by the LTP. The decrease in the air permeability of the LTP-treated wool fabric was found to be probably due to the plasma action effect on increasing in the fabric thickness and a change in fabric surface morphology. The change in the thermal properties of the LTP-treated wool fabric was in good agreement with the above findings and can be attributed to the amount of air trapped between the yams and fibers. This study suggested that the LTP treatment can influence the final properties of the wool fabric.

시판 한복지의 열.수분이동 특성 (Heat ,rind Moisture Transfer Properties of Fabrics for Korean Folk Clothes)

  • 성수광;성은정
    • 한국의류학회지
    • /
    • 제20권6호
    • /
    • pp.1071-1083
    • /
    • 1996
  • This study was carried out to obtain some fundamental data for designing thermally comfortable Korean folk clothes (KFC) which were classified into 4 groups according to seasons and materials. It was conducted to find the relationship among structural, thermal, and moisture transfer properties, and then the properties of heat and mositure transfer while changing thickness of air layer of selected similar fabrics with various thickness were examined. The summarized results of this study were as follows ; 1. The relationship between the structrual and thermal properties showed high positive correlation with thickness SE thermal insulation value (TIV), porosity & TIV. 2. The relationship between the structural and mositure transfer properties showed high negative correlation with thickness & moisture vapor permeability (Mp), porosity & Mp respectively. 3. The relationship between the heat and moisture transfer properites showed high negative correlation with qmax, air permeability (Ap), Mp & TIV while showed high positive with Ap & Mp respectively. 4. Resistance to dry heat transfer according to thickness of air layer for KFC was increassed rapidly up to 2 mm and above this increasing rate was reduced. Resistance to evaporative heat transfer was remarkable changes in 6∼8 mm but slowly in 6∼8 man. 5. Mioisture permeability index (i) according to thickness of air layer for KFC showed the greatest value at 2 mm but had not difference between groups according to thickness.

  • PDF

의류직물의 구성조건에 따른 열저항 특성 연구 (A Study on the Thermal Resistance of Wool Fabric Constructions)

  • 김태훈;전병익
    • 한국의류산업학회지
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2001
  • The purpose of this study was to determine the thermal characteristics of men's suits ensembles and their fabrics. For the study, 100% wool fabrics were woven with various fabric structure, fabric density and yam count and With the use of these, 12 men's suits were made with the same design. Physical characteristics that affect thermal transport properties, including drapery, cover factor; bulk density, keeping warmth ratio, vapor permeability, air permeability and porosity of the fabrics were measured. In addition, thermal resistance of men's suit ensembles, including Y-shirts, inner wear and socks was measured on the thermal manikin in the environmental chamber. The result of the study was as follows: 1. In terms of fabric structure, keeping warmth ratio of plain woven fabrics was higher than those of twill and satin woven fabrics and also, vapor and air permeability and porosity of plain woven fabrics were higher than those of twill and satin woven fabrics. 2. The result showed that thermal resistance of 12 ensembles were in the range of 0.77clo~0.97clo. 3. There was little correlation between woven condition such as, including structure, fabric density and yam count and thermal resistance of ensembles.

  • PDF

남성용 정장의 온열특성 연구 (Thermal Characteristics of Men's Suit Ensembles)

  • 송민규;전병익
    • 한국의류산업학회지
    • /
    • 제1권3호
    • /
    • pp.264-274
    • /
    • 1999
  • 최근에 사용되고 있는 남성용 정장 중, 여름용 30종, 겨울용 30종 등 총 60종을 시료로 하여 이들의 온열특성 중 보온성(무풍시=0.2 m/sec 이하, 풍속시=1.2 m/sec)과 이와 관련된 물성, 즉 공기투과도, 무게, 두께 등을 측정 및 분석하여 앙상블 및 가먼트의 보온성을 예측하는 회귀식을 개발하였다. 그 결과로는 일반적인 남성용 정장의 물성으로 두께 및 무게는 겨울용이 높았으며, 여름용과 겨울용을 확실히 구별할 수 있는 인지는 공기투과도였는데 여름용의 공기투과도는 겨울용보다 약 3~6배 정도 높았다. 남성용정장의 온열특성을 보면 겨울용 정장의 보온성이 여름용보다 높았고, 풍속이 있을 때 앙상블의 보온성은 최대 30% 정도 감소하는 경향을 나타내었다. 또한, 정장상하의 물성을 독립변수로 하여 가먼트 및 앙상블의 보온성을 추정하는 회귀식을 개발하였는데, 회귀식분석결과, 정장앙상블의 보온성에 영향을 주는 인자는 두께, 무게, 및 사이즈로 나타났다.

  • PDF

알루미늄 발포금속의 유효열전도도와 침투율의 측정 (Measurement of effective thermal conductivity and permeability on aluminum foam metal)

  • 백진욱;강병하;김서영;현재민
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.185-192
    • /
    • 1999
  • Effective thermal conductivities and pressure-drop-related properties of aluminum foam metals have been measured. The effects of porosity and cell size in the aluminum foam metal are investigated in detail. The porosity of the foam metal, considered in the present study, varies from 0.89 to 0.96 and the cell size from 0.65㎜ to 2.5㎜. The effective thermal conductivity is evaluated by comparing the temperature gradient of the foam metal with that of the thermal conductivity-known material. The pressure drop in the foam metal is measured by a highly precise electric manometer while air is flowing through the aluminum foam metal in the channel. The results obtained indicate that the effective thermal conductivities are found to be increased with a decrease in the porosity while the effective thermal conductivities ire little affected by the cell size at a fixed porosity. However, the pressure drop is strongly affected by the cell size as well as the porosity. It is seen that the pressure drop is increased as the cell size becomes smaller, as expected. The minimum pressure drop is obtained in the porosity 0.94 at a fixed cell size. A new correlation of the pressure drop is proposed based on the permeability and Ergun's coefficient for the aluminum foam metal.

  • PDF

견·인견과 셀룰로오스섬유 교직물의 쾌적성능 평가 (Comfort Properties of Silk#x00B7;Rayon-Cellulose Fiber Union Fabrics)

  • 배영희;윤창상;정운선
    • 한국지역사회생활과학회지
    • /
    • 제27권4호
    • /
    • pp.795-801
    • /
    • 2016
  • This study was conducted to suggest the best union fabric to combine with cellulose fiber for summer and in-between seasons. Four types of union fabric, viz. silk/flax, silk/cotton, rayon/flax and rayon/cotton, were used as sample fabrics after weaving them in a local textile factory. The air permeability, moisture regain, water absorption, water vapor permeability and thermal insulation of the samples were tested. The results are as follows. The rayon/flax union fabric is the most suitable for summer clothes due to its having the best comfort property of air and water vapor permeability, and moisture and water absorption. For in-between seasons, it is recommended to use the silk/cotton union fabric because of its good thermal insulation properties.

부직포 접착심지 부착 전후의 접착포의 열적 쾌적성과 공기투과성에 관한 연구 (A Study on the Thermal Comfort and Air Permeability of Adhesive Fabrics Before and After Adhesion of Nonwoven Adhesive Interlining)

  • 김경희;김승진
    • 한국의류학회지
    • /
    • 제22권7호
    • /
    • pp.807-815
    • /
    • 1998
  • Functions of interlinings to the shell fabric are to improve the garment formability for a beautiful silhouette and elastic potential to the deformed fabric during wearing, and also are to enhance appearance and wearing properties of garment. The objective of this study is to analyse the thermal properties of nonwoven fusible interlining to the thin worsted fabric with various fabric structural parameters. For the purpose fo this study, eight specimens with various weft yarn twists and weft densities of thin worsted fabrics are prepared. Three nonwoven fusible interlinings with different structure which were made by Nylon/Polyester were used for adhering to the thin worsted fabrics. Thermal properties of these 24 adhesive fabrics fused with 3 nonwoven interlinings are measured by KES-F7 System for analysing the thermal suitability of nonwoven fusible interlinings to the thin worsted fabrics with various fabric structural parameters. And air permeability, which was measured by KES-F8-API, of 24 nonwoven adhesive interlining fabrics was also analysed and discussed with the various kinds of nonwoven interlinings and fabric structural parameters.

  • PDF

종이 물성이 전열교환 엘리먼트 성능에 미치는 영향 (Effect of Paper Properties on the Performance of a Enthalpy Exchanger)

  • 김내현;조진표;송길섭;김동훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

면섬유 및 한지섬유의 자연염색 및 기능성광물처리에 의한 쾌적성의 변화 (The Change of Comfort Properties of Cotton and Hanjee Fabrics with Natural Dyeing and Functional Mineral Treatment)

  • 김성희
    • 한국의류산업학회지
    • /
    • 제12권2호
    • /
    • pp.219-223
    • /
    • 2010
  • In this study, the comfort properties of cotton and Hanjee fabrics dyed with Inonotus obliquus and treated with illite were evaluated and compared. Results were as follows; 1) W/T values and WC/W values of cotton and Hanjee fabrics were decreased when they were dyed with Inonotus obliquus and treated with illite. 2) Although air permeability of cotton fabrics was higher than that of Hanjee fabrics, air permeability of cotton and Hanjee fabrics dyed with Inonotus obliquus and treated with illite was decreased. 3) Thermal conductivity of cotton and Hanjee fabrics dyed with Inonotus obliquus was increased whereas thermal retain property was decreased. 4) Water absorption of Hanjee fabrics was higher than that of cotton fabrics. Water absorption of cotton and Hanjee fabrics dyed with Inonotus obliquus and treated with illite was increased. 5) Deodorization rate of Hanjee fabrics was greater than that of cotton fabrics.