• 제목/요약/키워드: Air operated valve

검색결과 60건 처리시간 0.025초

Linear compressor 토출밸브의 재질에 따른 마멸 특성에 관한 연구 (A study on wear with diacharge valve materials in linear compressor)

  • 박영도;구수학;김정해;박진성;이재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.899-903
    • /
    • 2009
  • Recently, research and development of the linear compressor are being active. The reason is that the one has not only higher efficiency than reciprocating type, but also lower noise. But because the dicharge valve of linear compressor is operated in high pressure and temperature circumstance, it is important to prevent leakeage. In this paper three other plastic reinforced composite materials were used. Those are TPI, PEEK and PEK which were containing other volume and kind of carbon fibers. First, for assessing mechanical properties, we measured the hardness and the heating property of the trst sepecimen by the microvickers hardness tester and the differential scanning calorimeter respectively. Finally, through FALEX tester, we could know the characteristics of the wear proving the results of before-conducted experiments.

  • PDF

마이크로 솔레노이드의 해석 및 설계 (Analysis and Design of Micro Solenoid)

  • 전용식;배상규;김동수
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가 (Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon)

  • 김창년;박영무;이병권;임종성
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

보일러 풍압 제어 계통의 모델링 (MODELING OF PRESSURE CONTROL SYSTEM OF BOILER)

  • 박민호;목형수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.362-366
    • /
    • 1987
  • The amount of inflowing Air into the boiler has controlled by manipulating the opening of valve, damper and vane, as fan operated by induction motor operats at constant speed, but these control methods are not efficient. Thus VVVf(Variable Voltage Variable Frequency) control of fan has selected to improve efficiency and to acquire power savings. Control system of Air Flow is affected by nonlinearity caused by load variation, vane opening, etc. The analysis of control parameter causing nonlinearity is needed to acquire optimal control and excellent transient response. This paper provides modeling of boiler with various load conditions and vane opening, and analysis of this system.

  • PDF

An Experimental Investigation of Thermodynamic Performance of R-22 Alternative Blends

  • Kim, Chang-Nyeon;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.36-44
    • /
    • 1998
  • R-410a and R-407c which have the best potential among R-22 alternatives were tested as drop-in refrigerants against a set of R-22 baseline tests. The performance evaluations were carried out in a psychometric calorimeter test facility using the residential spilt type air conditioner under the ARI rating conditions. Except the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly charged into the current refrigeration system because its vapor pressure and other thermochemical properties are similar to those of R-22. However, it is required to change the volume flow rate of compressor in order to achieve the volumetric capacity of R-22. This results from its relatively small VCR and capacity. Meanwhile, R-410a has vapor pressure values too high to be substituted for the current system and this resulted relatively low COP of R-410a compared to that of R-22.

  • PDF

유닛인젝터용 고속응답 솔레노이드 설계 및 응용에 관한 연구 (A Study on Design and Application of High Response Solenoid for Unit Injector)

  • 황재원;양이진;정영식;이상만;채재우
    • 한국자동차공학회논문집
    • /
    • 제6권1호
    • /
    • pp.43-51
    • /
    • 1998
  • Most of fuel-injection system operated with mechanical methods are difficult to control the injection quantity and injection timing as well as injection rate exactly. Moreover high pressure injection scheme is never be realized with conventional one. On the other hand, serious air pollution can be lessened with injection system equipped with those functions. Therefore, electronically controlled Unit Injuctor(UI) appeared to satify above mentioned desires. However, it is still difficult that the most important part, especially solenoid valve, is analyzed precisely, because of the existence of complex combination of electromagnetics, electrics and dynamic problems. In this study, experimental and theoretical analysis are accomplished for understanding of solenoid valve characteristics and further its design. As the result, the follows are obtained 1) As the increase of wire diameter, the response time became shorter and optimal inductance existed in relative with the response time and wire diameter. 2) According to increasing input voltage, the traction force increased, otherwise the response time was shortened. 3) As the increase of armature stroke, the traction force decreased and the response time became longer.

  • PDF

자동차 공조장치의 가변압축기 ECV 유량 분석 (Analysis of flow rate of variable displacement compressor ECV in automobile air conditioning control system)

  • 정준영;조행묵
    • 에너지공학
    • /
    • 제22권4호
    • /
    • pp.394-398
    • /
    • 2013
  • 최근들어 자동차에어콘 콤프레셔의 전기마그네트식 콘트롤밸브는 내부형 스워시 프레이트형을 사용하고 있다. 이 시스템은 외부로부터 공급되는 전류량(신호)에 의하여 작동되며 동시에 스워시판 작동에 의한 압력은 냉매가 흐르는 비율에 의하여 결정된다. 본 논문에서는 압축기의 크랭크케이스 압력이 전기마그네트 콘트롤 밸브 전기 흐름량에 따른 유량의 값을 측정하여 엔진의 효율을 향상시키고자 한다.

R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구 (An experimental investigation of thermodynamic performance of R-22 alternative blends)

  • 황의필;김창년;박영무
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

모터구동밸브의 성능 진단을 위한 모터 토크 분석 (Motor Torque Analysis for Motor-Operated Valves Performance Evaluation)

  • 권석준;이상회;박주문;성게용;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.337-341
    • /
    • 2002
  • 본 논문은 원자력 발전소의 안전에 있어 매우 큰 비중을 차지하는 모터 구동밸브(Motor-operated valve : MOV)의 성능진단에 직접 센서를 장착하지 않고 전기신호만을 이용하여 성능진단의 가능성을 보이기 위한 것이다. 모터 토크를 계산하기 위한 두 가지 방법으로서 D-Q frame 변환 방법과 Air-Gap 토크 식을 제시하였고, 계산된 두 토크 값은 정확하게 일치하였다. 부하를 변동하면서 토크미터로 측정된 토크 갑과는 1%의 오차범위 내에서 일치함을 확인했다. 따라서 두 토크 식은 모터구동 밸브의 성능진단을 위한 식으로 사용해도 좋다는 결론을 얻어낼 수 있었다. 계산된 토크를 주파수 분석함으로서 부하의 변동에 따라서 슬립 및 모터속도 주파수가 변화됨을 알 수 있었다. 즉 주파수 분석을 통해 MOV의 모터 및 구동기 부분의 성능 저하 감시에 유용한 단서를 제공해 줄 것이다. 결과적으로, MOV에서 전기신호의 분석은 시스템의 전기 및 기계적인 성능 저하 감시에 이용될 수 있을 것으로 기대된다.

  • PDF

Performance Evaluation of Motor-Operated Valve Using Electrical Signatures

  • Park, Joo-Moon;Joo, Hyung-Jun;Jung, Jae-Cheon;Sung, Key-Yong;Seong, Se-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.52-55
    • /
    • 2001
  • This paper is to see the availability of electrical signatures as a means for evaluating the performance and monitoring mechanical anomalies of (MOVs). To estimate motor torque, two methods such as d-q frame conversion and air-gap method are suggested and estimated results are compared with measured values. The error between measured and estimated torques is within acceptable error bound with below $1\%$ under varied load. Frequency domain analysis of calculated torque has been done as well. It is shown that monitoring of peak frequency could give useful clues to detect anomalies of MOV. As results, electrical signatures at MOV motor is expected to be an available tool for estimation of motor capacity and monitoring of electrical and mechanical abnormalities.

  • PDF