• 제목/요약/키워드: Air monitoring station

검색결과 142건 처리시간 0.023초

기상인자가 미세먼지 농도에 미치는 영향 (The Influence of Meteorological Factors on PM10 Concentration in Incheon)

  • 신문기;이충대;하현섭;최춘석;김용희
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.322-331
    • /
    • 2007
  • In this study, we have analyzed $PM_{10}$ concentration measured at Incheon Regional Air Monitoring Network (10 stations) and meteorological data at Incheon Weather Station to investigate factors (i.e. wind direction, wind speed, relative humidity, major meteorological phenomenon, and sea-land breezes existence) influencing $PM_{10}$ concentration in Incheon during 2005. Statistical differences among meteorological factors were assessed by Kruskal-Wallis test or Mann-Whitney U test. The main conditions causing high $PM_{10}$ concentration are summarized below; 1. When westerly wind prevailed (however, $PM_{10}$ decreased when winds were blowing from the east or north). 2. When the winds were calm, owing to accumulation of nearby emissions under stagnant conditions, or when the wind speed is in excess of 6 m/s, which shows the effect of fugitive dust produced by wind erosion. 3. Under the condition of high relative humidity and poor diffusion based on meteorological phenomenon such as fog, mist, and haze. 4. When the Sea-Land breezes existed, which occurred 70 days in Incheon during 2005 and contributed significantly to high $PM_{10}$ concentration in the coastal urban area. In conclusion, we have found that the meteorological factors have influence on $PM_{10}$ concentration in Incheon.

현장측정에 기초한 대기오염물질의 측정방식에 대한 비교연구-주요 기준성 오염물질을 중심으로 (Evaluation of Analytical Techniques for Some Gaseous Criteria Pollutants through a Field Measurement Campaign in Seoul, Korea)

  • 김세웅;김기현;김진석;이강웅;김경렬;문동민;김필수;손동헌
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.403-415
    • /
    • 1999
  • To properly assess air pollution levels, application of quality assurance and quality control(QA/QC) is believed to be an essential step. In order to cope with such scientific principle, a field study was designed with an aim of comparing: 1) the methods of calibration for airborne pollutants and 2) the protocols developed for their measurements. Measurements were made at Han Yang University, Seoul during 29 May through 1 June 1998 under the management of the Division of Measurements and Analysis(DMA) of Korean Society for Atmospheric Environment(KOSAE). In this work, we report our results of intercomparative measurements on several gaseous criteria pollutants that were investigated mainly by the two institutes-Seoul National University(SNU) and the Korean Research Institute for Standards and Science(KRISS). Although measurements of major gaseous pollutants had been made routinely by many scientific institutes and organizations in Korea, most scientists involved in those studieswere obliged to do their experiments on the basis of their own procedural steps spaning from the preparation of gaseous standards to the methodological selections for the calibration. Hence, this campaign offered a unique opportunity to examine many important aspects on the measurements of these important gaseous pollutants. In the course of our study, we investigated the compatibility of data sets obtained by the two institutes in concert with reference data sets collected concurrently from a government-managed monitoring station. On the basis of our study, we conclude that different data sets made by different participants during this campaign agree well within the reasonable range of uncertainties.low, which indicated that during this period the potential acidity of precipitation was high but the neutralizing capacity was low. For Spring, pAi was very low but pH was slightly high. This was likely due to the large amount of $CaCO_3$ in the soil particles transported over a long range from the Chinese continent that were incorporated into the precipitation, and then neutralized the acidifying species with its high concentraton.

  • PDF

오존농도의 動態 및 影響因子에 關한 硏究 (Studies on the Behaviour of Ozone Concentration and the Influencing Factors)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • 한국대기환경학회지
    • /
    • 제5권2호
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

Effect of Hydro-meteorological and Surface Conditions on Variations in the Frequency of Asian Dust Events

  • Ryu, Jae-Hyun;Hong, Sungwook;Lyu, Sang Jin;Chung, Chu-Yong;Shi, Inchul;Cho, Jaeil
    • 대한원격탐사학회지
    • /
    • 제34권1호
    • /
    • pp.25-43
    • /
    • 2018
  • The effects of hydro-meteorological and surface variables on the frequency of Asian dust events (FAE) were investigated using ground station and satellite-based data. Present weather codes 7, 8, and 9 derived from surface synoptic observations (SYNOP)were used for counting FAE. Surface wind speed (SWS), air temperature (Ta), relative humidity (RH), and precipitation were analyzed as hydro-meteorological variables for FAE. The Normalized Difference Vegetation Index (NDVI), land surface temperature (LST), and snow cover fraction (SCF) were used to consider the effects of surface variables on FAE. The relationships between FAE and hydro-meteorological variables were analyzed using Z-score and empirical orthogonal function (EOF) analysis. Although all variables expressed the change of FAE, the degrees of expression were different. SWS, LST, and Ta (indices applicable when Z-score was < 0) explained about 63.01, 58.00, and 56.17% of the FAE,respectively. For NDVI, precipitation, and RH, Asian dust events occurred with a frequency of about 55.38, 67.37, and 62.87% when the Z-scores were > 0. EOF analysis for the FAE showed the seasonal cycle, change pattern, and surface influences related to dryness condition for the FAE. The intensity of SWS was the main cause for change of FAE, but surface variables such as LST, SCF, and NDVI also were expressed because wet surface conditions suppress FAE. These results demonstrate that not only SWS and precipitation, but also surface variables, are important and useful precursors for monitoring Asian dust events.

대구지역 대기환경용량 산정에 관한 연구 (An Evaluation of Atmospheric Environmental Capacity in Daegu)

  • 박명희;최근식;정우식;김해동;이준수
    • 한국환경과학회지
    • /
    • 제19권10호
    • /
    • pp.1271-1281
    • /
    • 2010
  • This study aims to implement the modeling of selected substances for the evaluation of Atmospheric Environmental Capacity by means of the data of 2006 atmospheric pollution substance emissions. As a result, it turned out that the substance with the concentration higher than Atmospheric Environmental standard concentration was NO2, and 17.6% of the total regions researched turned out to exceed the standard concentration. In addition, set was the targeted amount to be reduced in the areas where the upper limit of emission per unit lattice was exceeded, and the model was adopted accordingly. As a result, it turned out that about 80% of the actual emission should be reduced to meet the 2006 Atmospheric Environmental standard over the Daegu. In reality, it is impossible to reduce 80% of the actual emission. Thus, the same ratio of reduction was applied in all of the Daegu regions, and the modeling was applied. The results are as follows: When 30% was reduced, the level went down to 50 ppb, which is as high as 2006 Atmospheric Environmental standard; when 50% was reduced, the level went down to 30 ppb, which is as high as 2007 Atmospheric Environmental standard.

2014년 강원 폭설동안 GPS 가강수량 탐측 (Remote Sensing of GPS Precipitable Water Vapor during 2014 Heavy Snowfall in Gangwon Province)

  • 남진용;송동섭
    • 한국측량학회지
    • /
    • 제33권4호
    • /
    • pp.305-316
    • /
    • 2015
  • GPS 상시관측소와 위성 신호 전송 과정에서 발생되는 대류권에서의 GPS 신호 지연은 가강수량을 복원하는데 사용되고 있다. 지상 기반의 GPS를 이용한 수증기 탐측 기술은 태풍 모니터링, 기후변화 추적을 장기간 수증기 관측 분야에서 유용하다. 본 연구에서는 2014년 영동지방에 폭설이 내리는 동안 우리나라의 GPS 가강수량 변화 추세를 분석하였다. GPS 가강수량이 증가된 이후 강설이 발생되는 경향이 나타났으며, 강릉과 울진에서 최대 GPS 가 강수량이 발생한 일정 시간 이후에 최대 신적설이 기록되었다. 또한 이번 폭설 이벤트 동안 고층기상관측시스템으로부터 분석된 K-index와 total index 및 GPS 가강수량에는 밀접한 상관관계가 있는 것으로 분석되었다.

제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가 (Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance)

  • 이연건;허재혁;이동원;현명택
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.70-79
    • /
    • 2018
  • 한국중부발전 제주화력본부에서 방류되는 온배수로부터 열원을 회수하여 약 3 km의 원거리에 위치하고 있는 신촌백합영농조합법인의 시설온실에 냉온수를 공급하기 위한 300 RT 용량의 열펌프 시스템을 구축하였다. 원거리 시설로 온배수열을 공급하기 위한 최적화 방안을 도출하였고, 수송관로의 온도와 누수여부를 모니터링하기 위한 설비들이 설치되었다. 본 논문에서는 제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템의 구성과 주요기기에 대해 기술하였다. 2018년 하절기에 열펌프 시스템의 냉방성능을 평가하기 위한 실증운전을 수행하였다. 냉방운전 시 열펌프 시스템의 주요 위치에서 측정된 유체의 온도와 유량, 그리고 냉방 성능계수를 분석하여, 구축된 열펌프 시스템의 안정성과 냉방성능을 검증하였다.

합성(合成)페로몬의 지상(地上)높이별(別) 위치(位置) 및 풍속(風速)에 따른 솔껍질깍지벌레 수컷의 비행(飛行) (Flight of Matsucoccus thunbergianae Males in Response to Synthetic Pheromone Placed at Various Heights above Ground and the Wind Speed)

  • 박승찬;위안진;김형선
    • 한국산림과학회지
    • /
    • 제89권1호
    • /
    • pp.135-140
    • /
    • 2000
  • 솔껍질깍지벌레의 수컷성충이 합성페로몬에 반응하여 비행하는 행동습성을 규명하고자 수직으로 세운 대나무 막대에 지상 0.1m부터 2.0m의 범위에 끈끈이 트랩을 5개 배열하고 그중 0.1m, 1.0m, 2.0m중의 한곳에 합성페로몬을 처리한 bait를 부착하여 각 끈끈이 트랩에서의 수컷부착수를 수관 울폐도별로 조사한 결과는 다음과 같다. 솔껍질깍지벌레 피해 해송림 근처의 공터에서, 페로몬 bait를 지상 2m 및 1m에 설치했을 때 동일 수직 막대상에 있는 각 높이의 트랩당 수컷부착수는 차이가 없었으나 지면근처에 bait를 설치한 경우 지면근처에 수컷이 집중적으로 비행하고 있었다. 수관 울폐도가 소한 임지의 경우, bait를 지상 2m에 설치한 것은 동일 수직막대상에 있는 각 높이의 트랩당 수컷부착수는 차이가 없었으나 지상 1m에 설치한 것은 bait 부위를 중심으로 많은 수컷이 비행하고 있었고, 수관 울폐도가 밀한 장소에서는 bait의 지상높이에 관계없이 수컷은 그 bait의 근처에서 많이 비행하고 있었다. 3개 지역 공히 지면부위에 bait를 설치한 처리구에서 지면부위의 트랩에 가장 많은 수컷이 부착되어 본 해충의 선단지 조사를 위한 페로몬 트랩 설치장소는 지면부위가 가장 적합한 것으로 판단된다. 풍속별 수컷의 페로몬에 대한 반응조사 결과, 페로몬을 감지한 수컷은 풍속이 낮은 공간을 주로 비행하는 것으로 조사되었다.

  • PDF

서울의 블랙카본 특성 연구 (The Characteristics of Black Carbon of Seoul)

  • 박종성;송인호;김현웅;임형배;박승명;신선아;신혜정;이상보;김정호
    • 환경영향평가
    • /
    • 제28권2호
    • /
    • pp.113-128
    • /
    • 2019
  • 2018년 가을철(9월 5일~10일, 6일간) 수도권대기오염집중측정소에서 미세먼지와 함께 블랙카본(BC, black carbon)의 농도 및 코팅두께를 파악하였다. 가을철 $PM_{10}$$23{\pm}12.6{\mu}g/m^3$, $PM_{2.5}$$12{\pm}5.8{\mu}g/m^3$으로 다른 계절보다 낮은 수준이었다. Aethalometer로 측정한 BC는 $0.73{\pm}0.43{\mu}g/m^3$, SOCEC로 측정한 EC(elemental carbon)는 $0.34{\pm}0.18{\mu}g/m^3$, SP2로 측정한 rBC(refractory-BC)는 $0.32{\pm}0.18{\mu}g/m^3$으로 측정방법에 따른 농도차이를 보여주었으나, 시계열 분포와 일 변동은 동일한 경향을 나타내었다. 수도권대기오염집중측정소에서 측정된 블랙카본은 자동차와 같은 일차오염원의 영향을 강하게 받았고, 주간과 야간의 출퇴근으로 인한 교통 혼잡 시간대에 높은 특징을 보였다. SP2로 측정한 $PM_{1.0}$ 단일입자에 대한 블랙카본의 개수농도는 84 nm에서 최고치로 관측되었으며, 코팅두께는 43 nm로 산정되었다. 특히 블랙카본 입자의 직경이 작을수록 코팅두께는 증가하였고, 입자의 직경이 증가할수록 코팅두께는 작아지는 특성을 나타내었다.

KOGA 기획과 활용연구 (Planning and Application of the Korea Ocean Gate Array (KOGA) Program)

  • 신창웅;박광순;노영재;장경일;방익찬;문일주;김태림;김봉채;김동선;김광희;김기완;노태근;임관창
    • Ocean and Polar Research
    • /
    • 제32권3호
    • /
    • pp.213-228
    • /
    • 2010
  • In late 2010, the Korea Hydrographic and Oceanographic Administration proposed a national monitoring project involving the deployment of 8 realtime ocean data buoys. The area occupied by the buoy-array, located south of the Ieodo Ocean Research Station, can be regarded as a kind of gateway to Korean waters with respect to warm currents and the shipping industry. The acronym for the project, KOGA (Korea Ocean Gate Array) was derived from this aspect. To ensure the success of the project, international cooperation with the neighboring countries of China and Japan is highly desirable. Once KOGA is successfully launched and the moored buoys start to produce data, the data will be applied to various areas such as data assimilation for operational oceanography, circulation dynamics, biogeochemical studies, satellite observations, and air-sea interactions. The aim of this paper is to provide suggestions for KOGA planning and applications.