• Title/Summary/Keyword: Air heating system

Search Result 1,322, Processing Time 0.025 seconds

Thermal Energy Characteristics for Greenhouse Heating System with Far-Infrared Heater (원적외선 면상발열체에 의한 온실 난방시스템의 열특성 분석)

  • Ro, J.G.;Kim, H.J.;Li, H.;Han, C.S.;Cho, S.C.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.529-534
    • /
    • 2006
  • The greenhouse heating system with far-infrared heater was built to analyze various thermal characteristics, such as greenhouse air temperature, soil temperature, energy flow, energy consumption in far-infrared heater, and other factors, which could be used in comparison with other greenhouse heating system in this study. The results showed that the inside air temperature of the far-infrared greenhouse heating system was $5^{\circ}C$ higher than that of hot air heating system. Heat loss of daytime was found to be larger than that of night time as much as 44.8% for the heating system with far-infrared heater. In the heating system with far-Infrared heater, when the lowest ambient temperature was -8 $\sim$ -7$^{\circ}C$, the air temperature of greenhouse was 12 $\sim$ 15$^{\circ}C$, thus the far-infrared heating system was shown to be feasible for heating system. Energy consumption of far-infrared heating system was shown to be less than that of hot air heating system.

A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement (T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구)

  • Jung, Daehan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse (탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과)

  • Paek, Y.;Jeon, J.G.;Yun, N.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

Simultaneous Heating and Cooling Multi-Air Conditioning System for Agricultural Products Management (농수산물 관리를 위한 냉난방 동시형 멀티 에어컨 시스템)

  • Shin, Jin-Seob;Hong, Ji-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.65-70
    • /
    • 2020
  • In this paper, to establish a high-efficiency air-conditioning and heating system, we developed a simultaneous air-conditioning and heating system that can do both air-conditioning and heating at the same time. It was applied to hybrid plant plants to enable automation of complex farms. For this purpose, the heat exchanger, which functions as a condenser during heating, was required to function as an evaporator during cooling so that air conditioning and heating could be implemented simultaneously. For experiments, the simultaneous air conditioning system for heating and cooling was produced and applied to the plant factories in the farms so that plants could be grown, stored, and dried. As a result, a single system was able to control the temperature environment of agricultural products with an energy-saving system that simultaneously resolves heating and cooling. Therefore, efficient crop management was possible by implementing an air conditioning system that did not require installing air conditioners and boilers at the same time.

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

Thermal Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump (열펌프에 의한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.155-162
    • /
    • 2001
  • The greenhouse heating system with heat pump was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air and soil and moisture content of soil in the greenhouse were developed, and its validity was justified by actual data. From the analysis of experimentally measured data and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the heating system with heat pump were very much close to the experimental values. 2. In the heating system with heat pump, the expected values of day time surface temperature of soil by computer simulation were very much similar to the measured values, but those of night time were higher than the measured value by at most 2.0$\^{C}$. 3. The simulation model predicted temperature of greenhouse film as of 1$\^{C}$ below than the mean value of ambient air and greenhouse air temperature. 4. Heat loss value of daytime was found to be larger than that of nigh as much as 1.3 to 2.3 times for the heating system with heat pump. 5. In the heating system with heat pump, when the lowest ambient temperature was -8$\^{C}$∼-7$\^{C}$ the air temperature of greenhouse was 5$\^{C}$∼6$\^{C}$, thus the heat pump heating system contributed in greenhouse heating by 13$\^{C}$.

  • PDF

A Study on the Bearing Characteristics of Air Bearing System According to the Thermal Effects (공기 정압 베어링에서 열의 영향에 따른 베어링 특성에 관한 연구)

  • 이종렬;김보언;안지훈;이득우
    • Tribology and Lubricants
    • /
    • v.17 no.1
    • /
    • pp.10-15
    • /
    • 2001
  • Generally, it is said that the heat generation of air bearing is negligible. But the air bearing using at the built-in spindle is different from the general air bearing itself because of the thermal effects from the spindle motor and high-speed conditions. In this paper, in order to analysis the characteristics of air bearing by the heat, We made easy -heating-bearing-system (EHBS) and hard-heating-bearing-system (HHBS) and could identify the changes between the two bearing systems from the experiments and simulation. When spindle system reached at thermal steady-state, the changes means that the stiffness of air bearing becomes change due to the clearance change between bearing and journal. It is shown that the temperature rise and thermal effects to cause the thormal expansions have to be considered when designing air spindle system.

A Study on the Passive Principle and its Practical Application of Air-conditioning System (난방을 비롯한 공기조화의 자연조절 방식과 현대적 응용에 관한 고찰)

  • Park, Soon-Kwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.105-112
    • /
    • 2004
  • The objective of this study is to observe today's situation and direction in relation with the natural air-conditioning and heating system to expand the architectural utilization of natural management for human comfort and energy conservation in architectural design. Also this study to provide the fundamental knowledge and. design-techniques on environment-friendly architecture in connection with 'natural idea in architecture'. In accordance with this intention, this thesis is composed of the following contents : 1) to understand the fundermental concepts about natural air-conditioning and heating system, 2) to review the traditional characteristics in Korean and Southeast Asian architecture related to natural air-conditioning and heating system, 3) to examine modern design-techniques in relation with natural air-conditioning and heating system in the selected area, 4) to attempt to synthesize the whole situation. Environment-friendly architecture using natural ideas and design-techniques in architecture is very important architectural aspect in a current architecture, also for the future. In spite of general considerations, it is expected that this study is use to understand the principle and practical application of natural air-conditioning and heating system in architectural design.

Growth Characteristics of Cherry Tomato in Greenhouse using Far Infrared Heating Systems (원적외선 난방시스템이 방울토마토 생육에 미치는 영향)

  • Kim, H.J.;Li, H.;Kang, T.H.;Ning, X.F.;Han, C.S.;Cho, S.C.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.161-166
    • /
    • 2009
  • This study was conducted to investigate the growth characteristics of cherry tomatoes in greenhouse using far infrared heating system. The far infrared greenhouse heating systems were installed in two ways on the greenhouse side wall and at the greenhouse ceiling. The heating characteristics of far infrared heating system were analyzed by investigating the heating load, internal temperature, energy consumption, growth characteristics and quality evaluation. The results were compared with heated air heating system using kerosene. The results showed that tomatoes grown in the greenhouse with the far infrared heating system had relatively better plant height, leaf length, leaf width, stem diameter than ones from the greenhouse with hot air heating system and both heating methods had no significant difference on Cherry tomato sugar contents. At the same time, the far infrared heating system reduced heating cost from 34.5 to 41.4% on comparing with hot air heating system.

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.