• 제목/요약/키워드: Air flow characteristics

검색결과 2,469건 처리시간 0.027초

온침 열특성의 기류 영향에 관한 연구 (Study of Air Flow Effects on Heat Characteristics of Warm Needle Acupuncture)

  • 김정우;이혜정;이승호
    • Korean Journal of Acupuncture
    • /
    • 제27권4호
    • /
    • pp.35-47
    • /
    • 2010
  • Objectives : To characterize the thermal properties of traditional warm needle and new warm needle with various air flows as an important environmental factor and to suggest the necessity of maintaining suitable environment of clinics to maximize their efficacy. Methods : We measured the temperature characteristics of traditional moxa warm needle and new moxa charcoal warm needle by applying an automatic temperature acquisition system with thermocouples while external various air flows were supplied. Temperatures of two positions at the needle body were measured while a moxa cone burned. Typical temperature characteristics like peak temperature, duration, curve shape and the efficiency of the heat stimuli by heat amount analysis were executed. Results : Both warm needles showed similar temperature curve with an increase in the air flow. Peak temperature and duration of effective heat decreased with the air flow, as shown in indirect moxibustion on garlic. The temperature change pattern by the air flow became more apparent when the total combustion heat was compared with the effective heat. The values from two positions on the needle body were significantly different, showing a distance dependency from the heat source of warm needle acupuncture. Conclusions : Thermal properties of warm needle acupuncture was observed variously with surrounding air flow of 0.0 - 0.7 m/s. It emphasized the importance of environmental control as well as the warm needle itself such as heat source and needle. The latter has already been known to deliver designated heat to subjects. It also indicated the importance of education and skill of the practitioners of warm needle acupuncture.

AIR ENTRAINMENT AND ENERGY DISSIPATION AT STEPPED DROP STRUCTURE

  • Kim Jin Hong
    • Water Engineering Research
    • /
    • 제5권4호
    • /
    • pp.195-206
    • /
    • 2004
  • This paper deals with oxygen transfer by air entrainment and energy dissipations by flow characteristics at the stepped drop structure. Nappe flow occurred at low flow rates and for relatively large step height. Dominant flow features included an air pocket, a free-falling nappe impact and a subsequent hydraulic jump on the downstream step. Most energy was dissipated by nappe impact and in the downstream hydraulic jump. Skimming flow occurred at larger flow rates with formation of recirculating vortices between the main flow and the step comers. Oxygen transfer was found to be proportional to the flow velocity, the flow discharge, and the Froude number. It was more related to the flow discharge than to the Froude number. Energy dissipations in both cases of nappe flow and skimming flow were proportional to the step height and were inversely proportional to the overflow depth, and were not proportional to the step slope. The stepped drop structure was found to be efficient for water treatment associated with substantial air entrainment and for energy dissipation.

  • PDF

포텐셜 코어내에 설치된 충돌평판상의 열전달증진 및 유동특성에 관한 연구 (Study on the flow characteristics and heat transfer enhancement on flat plate in potential core region of 2-dimensional air jet)

  • 이용화
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.193-201
    • /
    • 1998
  • A heat exchanging system employing the impinging air jet is still widely used In the various fields due to its inherent merits that include the easiness in engineering applications and the high heat and/or mass transfer characteristics. The purpose of this study is to investigate the enhancement of heat transfer and flow characteristics by placing a turbulence promoters in front of heat exchanging surface. In this study, a series of circular rods are placed at the upstream of a flat plate heat exchanger that is located at potential core region(H/W=2) of a two-dimensional impinging air jet. Heat transfer enhancement is achieved by inserting turbulence promoter that results in the flow acceleration and disturbance of boundary layer. The average Nusselt number of the flat plate with the turbulence promoters is found to be around 1.42 times higher than that of the flat plate without the turbulence promoters. Based on the results of flow visualization with a smoke wire, it is confirmed that the heat transfer enhancement is caused by the flow separation and disturbance of boundary layer by inserting the turbulence promoter.

  • PDF

A Study on Flow Characteristics of Polluted Air in Rectangular Tunnel Models Using a PIV System

  • Koh, Young-Ha;Park, Sang-Kyoo;Yang, Hei-Cheon;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.825-832
    • /
    • 2010
  • The objective of this study is to investigate flow behaviors of polluted air in order to prevent the impact of disaster in a tunnel. This paper presents the experimental results qualitatively in terms of flow characteristics in two kinds of rectangular tunnel models in which each distance from the centerline above the inlet vent to the exhaust vent is 0 and 60 mm, respectively. The olive oil is used as the tracer particles. The flow is tested at the flow rate of $14.16{\times}10^{-4}\;m^3/s$ and the inlet vent velocity of 1.1 m/s with the kinematic viscosity of air. The aspect ratio of the model test section is 10. The average velocity vectors, streamlines, and vorticity distributions are measured and analyzed by the Flow Manager in a particle image velocimetry(PIV) system. The PIV technology gives three different velocity distributions according to observational points of view for understanding the polluted air flow characteristics. The maximum value of mean velocity generally occurs in the inlet and outlet vent regions in the tunnel models.

소형축류형 터빈에서의 부분분사 유동특성에 관한 연구 (An Experimental Study of Partial Admitted Flow Characteristics on a Small Axial-Type Turbine)

  • 조종현;조수용;최상규
    • 한국유체기계학회 논문집
    • /
    • 제7권6호
    • /
    • pp.28-37
    • /
    • 2004
  • An experimental study is conducted to investigate flow characteristics on a small axial-type turbine which is applied as the rotating part of air tools. It operates in a partial admission due to consumption restriction of the high pressure air. In this operating condition, it is necessary to understand flow characteristics for obtaining the high specific output power. Tested turbine consists of two stages and the mean radius of flow passage is less than 10mm. A 6 bar pressure air is used to operate the turbine. The experimental results show that flow angles depend on the measuring location along the circumferential direction, but its discrepancy is alleviated along the axial direction. Absolute flow velocities show three times difference according to the measuring location at the exit of the first rotor due to the partial admission, but they show similar value at the exit of the second rotor by the velocity diffusion. From the measured flow angles and velocities, a ratio of output power obtained by the first and second rotor is estimated. It shows that the output power obtained by the second rotor is about $11\%$ to that by the first rotor at 60,000 RPM. It is effective therefore to improve the first rotor for increasing the turbine output power.

Supersonic Moist Air Flow with Condensation in a Wavy Wall Channel

  • Ahn, Hyung-Joon;Kwon, Soon-Bum
    • Journal of Mechanical Science and Technology
    • /
    • 제15권4호
    • /
    • pp.492-499
    • /
    • 2001
  • The characteristics of Prand시-Meyer expansion of supersonic flow with condensation along a wavy wall in a channel are investigated by means of experiments and numerical analyses. Experiments are carried out for the case of moist air flow in an intermittent indraft supersonic wind tunnel. The flow fields are visualized by a Schlieren system and the distributions of static pressure along the upper wavy wall are measured by a scanning valve system with pressure transducers. In numerical analyses, the distributions of streamlines, Mach lines, iso-pressure lines, and iso-mass fractions of liquid are obtained by the two-dimensional direct marching method of characteristics. The effects of stagnation temperature, absolute humidity, and attack angle of the upper wavy wall on the generation and the locations of generation and reflection of an oblique shock wave are clarified. Futhermore, it is confirmed that the wavy wall plays an important role in the generation of an oblique shock wave and that the effect of condensation on the flow fields is apparent.

  • PDF

PIV에 의한 냉장고 기류특성 평가방법 (A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV)

  • 김석로;도덕희;이재근;김경천
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF

소형 공조용 증발기의 특성 해석 (Analysis of Characteristics on Small Air-Conditioning Type Evaporator)

  • 김재돌;윤정인;김영수;문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.573-580
    • /
    • 2001
  • When investigating optimum design of the evaporator in the refrigeration and heat pump systems, there is still lack of data for the dynamic characteristics of the evaporator, This is due to the fact that the static characteristics in the evaporator are absolutely difficult to measure and are burdened with uncertainties. In this study, the simulation works for static characteristics in the evaporator of small air conditioner are carried out to obtain the data of dynamic characteristics. In the simulation, the test evaporator is divided by two-phase evaporating region and single-phase heating region. The major parameters are refrigerant flow rate, heat transfer coefficient of air, air velocity and air temperature. The results show that the calculation method for tube length is an easy-to-use to model analysis of static characteristics and to determine state of refrigerant in the evaporator. The effects of the four parameters on the length of evaporating completed point and heat flow rate to the evaporator are clarified.

  • PDF

연료 및 공기 노즐 위치와 공기 유량 변화에 따른 MILD 연소 특성에 관한 해석적 연구 (A Numerical Study of the Combustion Characteristics in a MILD Combustor with the Change of the Fuel and Air Nozzle Position and Air Mass Flow Rate)

  • 김태권;심성훈;장혁상;하지수
    • 대한환경공학회지
    • /
    • 제33권5호
    • /
    • pp.325-331
    • /
    • 2011
  • 연소과정 중에 발생하는 질소산화물을 저감하는 기술인 MILD 연소에 대하여 연료노즐과 공기노즐의 위치와 공기유량을 변화하면서 나타나는 연소특성을 수치해석을 통하여 연구하였다. 본 연구의 MILD 연소로는 연료노즐과 공기 노즐 사이에 연소배기가스의 배출구가 있는 연소로를 이용하였다. 공기노즐은 8개, 연료노즐은 4개를 사용하였다. 연료노즐이 연소로 중앙 부근에 위치한 연소로의 경우에 공기유량이 적을 때는 연소반응대가 연료노즐에서부터 연소로 벽면으로 치우치게 되지만 공기유량이 커지면 연소반응대가 연료노즐 측에서 시작하여 연료노즐 상부로 형성된다. 공기노즐이 연소로 중앙부분에 위치한 경우에 공기유량이 적을 때는 연소반응대가 공기노즐 부근에서 시작하여 연소로 벽면으로 치우치지만 공기유량이 증가하면 연소반응대가 연료노즐 측으로 옮겨가게 된다. 두 가지 경우 모두 공기유량이 증가하면 연소반응대에서 최대온도가 증가하고 따라서 배기가스에서의 NOx 농도가 증가한다. 두 가지 노즐 위치에서의 NOx 생성을 비교해 보면 공기노즐이 연소로 중앙에 위치한 경우가 연료노즐이 연소로 중앙에 위치한 경우보다 NOx 농도가 현저히 적음을 알 수 있었다. 본 연구의 결과로부터 NOx 저감과 연료의 미연가스 배출을 감안할 때 공기노즐이 연소로 중앙에 위치하고 이론공기량에 해당하는 공기량을 분출할 때 NOx 생성에 가장 효과적임을 알 수 있었다.

소형 스크류식 원심펌프의 기액 이상류 특성 (Characteristics of a Small Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow)

  • 김유택;다나카카즈히로;이영호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.9-15
    • /
    • 1999
  • A screw-type centrifugal pump was manufactured to carry primarily solids and its impeller had a wide flow passage. However, there was an effect on the flow passage shape on delay of the choke due to entrained air not being clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For this reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that there was a loss of pump head from single-phase flow to the choke due to air entrainment near the best efficiency point being large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF