• 제목/요약/키워드: Air distribution

검색결과 3,519건 처리시간 0.026초

외기 도입에 따른 바닥급기 시스템의 에너지 사용량 분석 (Analysis of the Energy Consumption in Underfloor Air Distribution System depending on Outdoor Air Intake Rates)

  • 김동희;허정호;조동우;유기형;유지용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.826-831
    • /
    • 2006
  • In this paper, we discussed the energy performance of underfloor air distribution(UFAD) and overhead air distribution system according to outdoor air intake rates in a office building. For this, the laboratory(S lab.) is selected for measuring the thermal environments of UFAD system and overhead system. Based on the measured data, the TRNSYS simulation is used to evaluate the energy performance of UFAD system and the overhead system according to outdoor air intake rates. By increasing outdoor air intake rates from required outdoor air intake rates(100CMH) to maximum air intake rates, the energy savings of UFAD system comparing with overhead system are varied $15%{\sim}25.6%$ in summer, $12.8%{\sim}19%$ in fall/spring and not varied in winter(8%). As results of simulations on stratification height and cooling set temperature, the lower the stratification height and the higher cooling set temperature, the larger cooling energy savings of UFAD comparing with overhead system according to outdoor air intake rates.

  • PDF

부산지역 오존 및 이산화질소 농도의 공간분포해석에 따른 대기오염측정망 배치연구 (A Study on Allocation of Air Pollution Monitoring Network by Spatial Distribution Analysis of Ozone and Nitrogen Dioxide Concentrations in Busan)

  • 유은철;박옥현
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.583-591
    • /
    • 2004
  • In this study, methodologies for the rational organization of air pollution monitoring network were examined by understanding the characteristics of temporal and spatial distribution of secondary air pollution, whose significance would increase hereafter. The data on $O_3$ and $NO_2$ concentrations during high ozone period in 1998~1999 recorded at the nine air pollution monitoring station in Busan were analysed using principal component analysis (PCA) and cumulative semivariogram. It was found that the ozone concentration was deeply associated with the daily emission characteristics or the $O_3$ precusors, and nitrogen dioxide concentration largely depends on the emission strength of regional sources. According to the spatial distribution analysis of ozone and nitrogen dioxide in Busan using cumulative semivariograms, the number of monitoring stations for the secondary air pollution can be reduced in east-west direction, but reinforced in north-south direction to explain the spacial variability. More scientific and rational relocation of air pollution monitoring network in Busan would be needed to investigate pollution status accurately and to plan and implement the pollution reduction policies effectively.

관에서의 입자농도분포 제어에 관한 수치적 연구 (A NUMERICAL STUDY ON THE CONTROL OF PARTICLE CONCENTRATION DISTRIBUTION IN A PIPE)

  • 이민영;유주식
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.62-66
    • /
    • 2009
  • The control of particle concentration distribution in a pipe with an orifice and a sheath air is numerically investigated. When using Eulerian approach, there is no great change in the concentration distribution by the shape of orifice and molecular diffusivity. As the Reynolds number becomes small, the effect of orifice on the concentration distribution is decreased. For small Reynolds number, the concentration distribution can be effectively controlled by using a sheath air. The effect of the sheath air on the concentration distribution is increased, as the Reynolds number becomes small.

Study on the Effect of Air Circulator on Temperature Distribution in an Oyster Mushroom Farm

  • Jeong, Won Geun;Lim, Hack Kyu;Kim, Tae Han
    • Journal of Biosystems Engineering
    • /
    • 제38권2호
    • /
    • pp.81-86
    • /
    • 2013
  • Purpose: Recently, domestic and abroad consumption of mushroom has been increasing. Especially, oyster mushroom has been the most consumed product, sharing one third of the mushroom market. The air temperature differences between relative positions of the mushroom farms were needs to be minimal. However, in reality, the air temperature differences ranged from 2 to $5^{\circ}C$. Because of this, the mushrooms are non-uniform growth as well as decrease in both quality and quantity. Although air circulators have been employed by oyster mushroom farms to minimize air temperature differences, no experiments have been performed to illustrate the effect of the air circulators. Methods: This experiment is designed to analyze the effect of the air circulation by constructing a prototype air circulator and measuring the air temperature when the circulator was position at different heights (50 cm, 150 cm, 200 cm) from the floor in the center. Result: The horizontal plane air temperature of the first growing bed when the air circulator was installed 50cm above the floor in the center, once not using the air circulators and the other time using the air circulators, yielded the air temperature differences of $8.6^{\circ}C$ and $1.8^{\circ}C$ and deviations of 2.82 and 0.60, respectively. The third growing bed's air temperature differences were $10.0^{\circ}C$, $1.6^{\circ}C$ and deviations 3.28, 0.64, each respectively. These outcomes proved that the use of air circulators minimized the air temperature difference and deviation. The use of air circulators helped minimize the air temperature differences and the derivations in oyster mushroom farm. Conclusion: The use of air circulators helped balance the air temperature distribution in oyster mushroom farm.

대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구 (An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube)

  • 황승식
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

원전 배합 콘크리트의 외기대류계수에 관한 연구 (Study on the Coefficient of Air Convection for Concrete Mix of Nuclear Power Plant)

  • 이윤;김진근;최명성;송영철;우상균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.148-151
    • /
    • 2004
  • The hardening of concrete after setting is accompanied with nonlinear temperature distribution caused by development of hydration heat of cement. Especially at early ages, this nonlinear distribution has a large influence on the tensile cracking. As a result, in order to predict the exact temperature distribution in concrete structures it is required to examine thermal properties of concrete. In this study, the coefficient of air convection for concrete mix of nuclear power plant, which presents thermal transfer between surface of concrete and air, was experimentally investigated with variables such as velocity of wind and types of form. The coefficient of air convection obtained from experiment increases with velocity of wind, and its dependance on wind velocity is varied with types of form. This tendency is due to a combined heat transfer system of conduction through form and convection to air. The coefficient of air convection for concrete mix of nuclear power plant obtained from this study was well agreed with the existing models.

  • PDF

냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성 (Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser)

  • 한화택;신민우;염철민;최선호
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

냉장고 내부의 냉기 유동특성에 관한 3차원 해석(I) (3-Dimensional Calculation on Cold Air Flow Characteristics in a Refrigerator)

  • 오민정;이재헌;오명도
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.382-395
    • /
    • 1995
  • A numerical study has been performed on flow characteristics in a domestic refrigerator whose size is $540mm{\times}1,530mm{\times}680mm$, considering existence of a fan and evaporator. The flow field has been simulated with the low Reynolds number $k-\bar{\varepsilon}$ turbulent model and SIMPLE algorithm based on the finite volume method. The region of fan which makes driving force for cold air distribution was modeled as a region in which momentum sources are generated uniformly. The concept of the distributed pressure resistance was applied to describe the momentum loss from evaporator. The result showed that the rate of cold air distribution into freezing room and cold storage room was almost 7 : 3.

  • PDF

Experimental Investigation on Air-Distribution in a Water-Flowing through a G1-Rod Bundle with Helical Spacers

  • Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.79-86
    • /
    • 1978
  • 본 연구의 목적은 수직 연료봉 집합체에서 물-공기 2상 유동일 경우 공기분포현상에 관한 실험적 데이타를 얻는데 있다. test-section은 6각형, 61개의 연료봉 집합체로 구성되며, 각 연료봉은 helical spacers로 감겨져 있고, 사용되는 유체는 공기와 물이다. 실험은 크게 2부분으로 나누어서 물의 유량을 일정하게 하고 공기의 유량을 증가시킬 경우와 물자 공기의 유량을 동시에 증가시킬 경우의 공기분포현상에 관해 실시하였다. 공기는 4구멍을 통해 각각 주입시켰다. 보이드율의 측정은 전기적 Void-needle 방법을 적용하였으며 그 결과는 도표를 통해 보여주고 있다. 이 실험의 결과로써 물의 유랑을 증가시킬 수록 공기분포는 균일하게 되며, 공기 공급 위치는 공기분포에 큰 영향을 미치고 있음이 입증되었다.

  • PDF

알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험 (Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator)

  • 김내현;신태룡;심용섭
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.