• 제목/요약/키워드: Air diffusion Performance Index

검색결과 15건 처리시간 0.024초

학교건물에서 냉방부하에 따른 열적 쾌적성 평가지표 비교 연구 (A Study on the Comparison of Thermal Comport Performance Indices for Cooling Loads in the Classroom)

  • 노광철;오명도
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1274-1279
    • /
    • 2004
  • We performed the numerical study on the comparison of thermal comport performance indices for cooling loads in the classroom when the 4-way cassette air-conditioner is mounted on the ceiling. We investigated the velocity and the temperature distribution of the classroom as with respect to the variation of the air diffusion angle of the air-conditioner. Air diffusion performance index and Predicted mean vote were used for analyzing the characteristics of the thermal comport in the classroom and comparing their values each other. From the numerical results, we knew that the thermal comport is largely affected by the air diffusion angle and velocity of the air-conditioner. And we also found out that the qualitative tendency of the distribution between Air diffusion performance index and Predicted mean vote is very similar in all occupied zone.

  • PDF

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

교실에서의 천장형 냉난방기의 취출온도 및 취출각도에 따른 열환경 시뮬레이션 (Computer Simulation on the Thermal Environment by the Diffusion temperature and Diffusion Angle of Ceiling Type Air Conditioner in Classroom)

  • 박효순;박승익;이상혁;이감규
    • 교육녹색환경연구
    • /
    • 제4권4호
    • /
    • pp.1-18
    • /
    • 2004
  • Research has been carried out to study thermal environment in a classroom under three kinds of air diffusion temperature and six kinds of air diffusion direction for ceiling type air conditioner. The velocity and temperature distributions of air in the room calculated by 3-dimensional numerical method(PHOENICS), This present study was also conducted to calculate the Air Diffusion Performance Index(ADPI) for cooling conditions and Predicted Percentage of Dissatisfied(PPD) for heating conditions. This analysis shows that the optimum angle of ceiling type air conditioner's diffusion is $15{\sim}30^{\circ}$ for cooling mode and about $15{\sim}45^{\circ}$ for heating mode in these calculating conditions. And also analysis has been carried out to evaluate thermal comfort of vertical and horizontal cross section of classroom.

  • PDF

A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner Coupled with Ventilation System

  • Kwon, Yong-Il;Han, Hwa-Taik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.101-107
    • /
    • 2007
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in two different ways in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구 (A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space)

  • 임석영;장현재
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

환기시스템이 적용된 히트펌프의 난방시 급기효율 평가에 관한 연구 (A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner with Ventilation System for Heating Season)

  • 권용일;한화택;김경환;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.56-61
    • /
    • 2005
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.

태양일사가 실내공간의 열적 쾌적성과 환기성능에 미치는 영향에 관한 연구 (The study on the effect of the solar radiation on thermal comfort and ventilation performance in room space)

  • 연성현;이효준;리광훈
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.19-26
    • /
    • 2016
  • Modern people spend much time at indoor space. So, People want to make better indoor air condition. But the facade of building is made of glass to be seen urbanely, the effect of solar radiation makes indoor environment worse. This study designs an open space affected by solar radiation with 4-way cassette air-conditioner. Using numerical simulation, this paper investigates thermal comfort and ventilation performance with discharge angles $30^{\circ}$ and $45^{\circ}$. To study thermal comfort, this paper studies distribution of velocity, temperature and effective draft temperature. Also, this paper introduces concept of air age to study ventilation performance. The flow influenced by solar radiation determines thermal comfort and ventilation performance in room space. This study shows that discharge angle of 45 degree has better thermal comfort and ventilation performance than that of 30 degree.

강의실에서의 냉방부하에 따른 열쾌적성 평가지표 비교 - PMV와 EDT의 연관성 - (Comparison of Thermal Comfort Performance Indices for Cooling Loads in the Lecture Room - An Correlation of PMV Bnd EDT -)

  • 노광철;오명도
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.868-877
    • /
    • 2005
  • We performed the experimental and the numerical study on the comparison of thermal comfort performance indices for cooling loads in the lecture room for 4 cases: Fan coil unit(FCU) or 4-way cassette air-conditioner is respectively operated with the ventilation system or without. We measured the velocity, the temperature distribution and predicted mean vote(PMV) value in the lecture room for 4 different air-conditioning methods. Effective draft temperature(EDT) and PMV were investigated to analyze the characteristics of two thermal comfort indices in the lecture room and to compare their values each other. From the results we knew that there is the similarity between PMV values and EDTs when the room is air-conditioned for cooling loads. It turned out that definition of the control temperature is very important when the EDT is calculated. Finally EDT should not be used to predict the accurate thermal comfort in case that the temperature and humidity are suddenly varied and the zone affected by the solar and inner wall radiation.

천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성 (Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space)

  • 성상철;김혁순;진심원;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF