• Title/Summary/Keyword: Air collecting

Search Result 166, Processing Time 0.054 seconds

A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling (청정에너지 회수용 유증기/매연 포집모듈에 관한 연구)

  • Kim, Myung-Soo;Ohkura, Shigenobu;Ham, Koung-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

Predicted Optimum Efficiency due to Changes in the Design Parameters of the Small Electrostatic Precipitator (설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측)

  • Suh, Jeong-Min;Yi, Pyong-In;Jung, Moon-Sub;Park, Jeong-Ho;Lim, Woo-Taik;Park, Chool-Jae;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1187-1197
    • /
    • 2013
  • The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.

An advanced study of multi-stage type hydrocyclone dust collector for fish egg collecting using Visualization (가시화기법을 이용한 다단형 하이드로 사이클론 어란 (魚卵) 집진장치의 개선에 관한 연구)

  • CHOI, Eunhee;PYEON, Yongbeom;LEE, Seung-heon;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.404-412
    • /
    • 2017
  • A centrifugal cyclone dust collecting apparatus includes a hydro cyclone dust collecting apparatus for separating solid or liquid using liquid or suspension as a medium. In this study, the formation mechanism and improvement of air core and inner air layer were confirmed through Particle Image Velocimetry. These results showed that the modified experimental model was designed in the conventional method suitable for the separation of juvenile fish and eggs. The inlet speed of the multi-stage hydrocyclone dust collector, which can increase the inlet velocity and minimize floatage in the turbulence chamber, was increased from 0.15 to 0.30 m/s. As a result, the air core was stably formed, the inner air layer was increased with increasing speed. In addition, the dust collecting efficiency of egg and juvenile fish was 97.8% on average, It can infer that this system confirmed the ability to efficiently collect particles of $40{\mu}m$ or more.

Computational Study of Energy Loss in a Pipe of Refuse Collecting System (쓰레기 관로운송 시스템의 운송에너지 손실에 관한 수치해석적 연구)

  • Lee, Jong-Gil;Byun, Jae-Ki;Choi, Young-Don;Choi, Yoon;Hong, Ki-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes energy loss in a pipe line of refuse collecting system. Analysis of energy loss in a pipe line is the decisive factor in a design of refuse collecting system. Using the results of energy loss analysis, we can determine the power of turbo-blower. The flow characteristics of the pipe line with refuse bags were analyzed by three-dimensional CFD. The refuse bag is modeled by using the shape obtained from profile measurement. Friction factors were calculated with changing the refuse bag size, mixing ratio and Reynolds number. And drag coefficients were calculated using the CFD results. From the results we can calculate energy loss in a pipe line of refuse collecting system and predict the capacity of turbo-blower.

A Study on the Safety Management of UAS by Analyzing Its Accident Factors (무인항공기시스템 사고요인 분석을 통한 안전 운용방안 고찰)

  • Wontae Park
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • This study investigated the accident cases of the U.S. Air Force and the R.O.K. Army. It analyzed the accident factors of the unmanned aircraft system using case analysis on unmanned aircraft system operators of the R.O.K. Air Force. Following the analysis this paper suggested safety operation plans for the R.O.K. Air Force. The risk factors of unmanned aircraft system were summarized by collecting and analyzing accident cases of unmanned aircraft system by the U.S. Air Force, collecting and analyzing accident risk factors of RQ-4 operators of the R.O.K. Air Force. Through the analyzed risk factors, a safety operation plan for the semi-automatic unmanned aircraft system and the fully automatic unmanned aircraft system was presented.

An Experimental Study on the Condensation Characteristics with Solar Radiation and Tilted Angles

  • Kim, Byung-Chul;Koh, Young-Ha;Lee, Cheun-Gi
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.4
    • /
    • pp.123-128
    • /
    • 2009
  • In this paper, effective ways to produce distilled water with solar radiation was investigated. Four different boxes of condensation systems were compared. The bottoms of the boxes were identical, but the angles of the top collecting plates were different. During the solar radiation, condensation did not occur. Condensation started when solar radiation was decreased. The maximum condensation was found when the temperatures of the top and bottom parts were equal. The condensation was continued until sunrise with gradually reduced rate. When the collecting plate angle was $45^{\circ}$, condensation was the highest compared with other angles.

A Survey on Management Status of Personal Air Sampler in Domestic Provider for Work Environment Monitoring Service (국내 작업환경측정기관들의 개인시료 채취기 운용현황 실태 조사)

  • Kim, Ki-Youn;Cho, Man-Su;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.359-364
    • /
    • 2014
  • Objectives: The principal aim of this study is to provide fundamental data for suggesting substantial management plan of personal air sampler by investigating current situation of work environment monitoring service provider. Materials and Methods: The questionnaires regarding a personal air sampler were sent by electronic mail to 150 institutions, except for 22 institutions which are out of business or closed temporarily, among total 172 domestic work environment monitoring service providers designated by Ministry of Employment and Labor based on 2013. The institutions which did not reply to the questionnaire for 30 days were required directly by phone call. Finally 97 institutions gave an answer to the questionnaire and therefore the respondence rate was 65%. Results: The normal operation rate of personal air sampler exceeded 70% in all the types (particle, gas and both combination) in terms of purchased year. Furthermore the personal air sampler purchased recently showed a trend of high operation rate compared to the personal air sampler purchased previously. The distribution patterns of personal air sampler In terms of manufacturers were Gillian>MSA>SKC for particle, Gillian>SKC>AMETEK for gas and Gillian>MSA>Casella for both combination, respectively. As a result, it was found that the personal air sampler manufactured by Gillian company was utilized the most in domestic work environment monitoring service provider regardless of types of personal air sampler. Conclusions: Based on the results obtained from this study, the normal operation rate according to types of personal air sampler was as follows: 94% for personal air sampler for collecting particle only, 93% for personal air sampler for collecting gas only and 89% for collecting both particle and gas. Overall, the numbers of personal air sampler possessed and operated normally in domestic work environment monitoring service provider were 5,458 and 5,062, which indicates the normal operation rate of personal air sampler in total aspect is 93%.

Flow Characteristics of Piping System Having Various Shapes in Refuse Collecting System (관로 형상에 따른 생활폐기물 이송시스템의 유동특성)

  • Jang, Choon-Man
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper describes flow characteristics in a piping system having various duct shapes on refuse collecting system. A simulator for the refuse collecting system is designed to analyze the flow characteristics in the piping system. The simulator consists of an air intake, a waste chute, circular duct having various shapes, cyclone and turbo blower. The simulator has four different duct shapes: straight, curved, inclined and Y-shaped ducts. Three-dimensional Navier-Stokes analysis is introduced to analyze the pressure loss in the piping system. Throughout the numerical simulation, pressure loss obtained by numerical simulation has a good agreement with the results of experimental measurements. The selected length of curved and Y-ducts for the pressure loss is determined using pressure distributions on the duct. Flow and pressure characteristics in the piping system of the simulator are evaluated by numerical simulation and discussed in detail.

Computational Study of Energy Loss in a Pipe of Refuse Collecting System (쓰레기 관로운송 시스템의 운송에너지 손실에 관한 수치해석적 연구)

  • Lee, Jong-Gil;Choi, Yoon;Hong, Ki-Chul;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.421-426
    • /
    • 2009
  • This paper describes on energy loss in a pipe of refuse collecting system. Analysis energy loss in a pipe is the decisive factor in a design for refuse collecting system. From the analysis energy loss, we can determine the capacity of turbo blower. The flow characteristics in the pipe with the refuse bag are analyzed by three-dimensional Navier-Stokes analysis. The refuse bag is modeled using the actual measurement. We obtain friction factor by changing refuse bag's size and mixing ratio and Reynolds number. And From the result we calculate energy loss by using compressible flow analysis.

  • PDF

Effect of Current Collecting Layer on the Impedance of LSM and LSM-YSZ Cathode (LSM 및 LSM-YSZ 양극의 임피던스 특성에 미치는 집전층의 효과)

  • 문지웅;이홍림;김구대;김재동;이해원
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1070-1077
    • /
    • 1998
  • Effect of current collecting layer on the cathode was characterized by AC impedance spectroscopy at 800$^{\circ}C$ under flowing air. LSM-YSZ composite cathode showed lower polarization resistance due to the in-crease of triple phase (LSM/YSZ/Pore) boundary length by incorporation of YSZ. Ohmic resistance {{{{ {R }_{1 } }} of LSM-YSZ was higher than that of pure LSM however because in-plane resistance of the cathode was fair-ly high due to its high specific resistivity. To reduce the in-plane resistance of LSM-YSZ cathode cathode side current collecting layer was required. Ohmic resistance {{{{ {R }_{1 } }} was reduced after forming LSM current col-lecting layer on the LSM-YSZ cathode. In case of pure LSM cathode the formation of Pt, or LSCO current collecting layer reduced polarization resistance {{{{ {R }_{p } }} but ohmic resistance {{{{ {R }_{1 } }} was relatively constant. After annealing of LSM cathode with Pt current collector at higher temperature polarization resistance {{{{ {R }_{p } }} was in-creased but ohmic resistance {{{{ {R }_{1 } }} was constant. These phenomena indicate that Pt or LSCo current col-lecting layers act as a catalytic layer for oxygen reduction of pure LSM cathode. LSCO current collector was effective in reducing the ohmic and polarization resistance of LSM-YSZ cathode.

  • PDF