Search Result 289, Processing Time 0.029 seconds

Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building (대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Byun, Jae-Ki;Jeong, Dong-Hwa;Lee, Jong-Gil;Hong, Seong-Ho;Choi, Young-Don;Cho, Sung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF

A Study on Operating Method to Save Energy from the Adsorption Dryer in the Process of Purifying Compressed Air (고순도 압축공기 제조시스템의 흡착식 Dryer에서 에너지절감을 위한 운전방법에 관한 연구)

  • Kang, Seok-Wan;Chang, Sung-Ho;Kim, Hyeon-Joon;Kim, Sung-Soo;Lee, Yeong-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.180-191
    • /
    • 2016
  • Optimizing energy usage for maximum efficiency is an essential goal for manufacturing plants in every industrial manufacturing sector. The generation and distribution of purifying compressed air is a large expense incurred in practically all manufacturing processes. Not only is the generation and treatment expensive equipment of compressed air, but frequent maintenance and effective operation is also required. As a plant's compressed air system is often an integral part of the production process, it needs to be reliable, efficient, and easy to be maintain. In this paper, we study to find operating method to save energy from the adsorption dryer in the process of purifying compressed air, which is required for a clean room production site in "A" company. The compressed air passes through a pressure vessel with two "towers" filled with a material such as activated alumina, silica gel, molecular sieve or other desiccant material. This desiccant material attracts the water from the compressed air via adsorption. As the water clings to the desiccant, the desiccant particle becomes saturated. Therefore, Adsorption dryer is an extremely significant facility which removes the moisture in the air $70^{\circ}C$ below the dew point temperature while using a lot of energy. Also, the energy consumption of the adsorption dryer can be varied by various operating conditions (time, pressure, temperature, etc). Therefore, based on existing operating experiments, we have searched operating condition to maximize energy saving by changing operating conditions of the facility. However, due to a short experiment period (from September to October), further research will be focused on considering seasonality.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

Study on Development of Portable Incubator (휴대용 인큐베이터의 개발에 관한 연구)

  • Eizad, Amre;Zahra, Falak;Alam, Hamza;Tahir, Hassan;Bangash, Afrasiab Khan;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.1-6
    • /
    • 2019
  • Preterm children require a controlled environment that is as close as possible to that inside the womb. Incubators are well equipped to fulfill this requirement; however, they are cumbersome and expensive, thereby restricting their portability and availability in less developed and rural areas. This research comprises the development and system validation of a portable incubator. The system consists of a collapsible baby enclosure that can be stowed inside the system base when not in use. The enclosure is made from acrylic such that it is easy to clean and allows unhindered visual observation of the occupant while being robust enough to withstand transit conditions. The system can be powered either by a mains supply or a 12-VDC automobile power supply. Additionally, it has an onboard battery to ensure a continuous supply during transit. A Peltier plate controlled using a microcontroller ensures the desired enclosure temperature irrespective of the ambient temperature. Built-in sensor probes can measure the skin temperature, pulse rate, blood oxygenation level, and ECG of the infant and display them on the system screen. The system function is validated by testing its peak power consumption and the heating and cooling performances of the environment control system.

A filed operation characteristics and the controversial point of Photovoltaic power generation system (태양광 발전시스템의 현장 운전특성 및 문제점)

  • Koh, Kang-Hoon;Suh, Ki-Young;Lee, Hyun-Woo;Hong, Doo-Sung;Gang, Yeong-Cheol;U, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.381-383
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using da transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

Flow Analysis around the Roller Conveyor in a Clean Room (클린룸 내 롤러 컨베이어 운송장치 주위의 유동해석)

  • Jeon, Hyun-Joo;Park, Chan-Woo;Im, Ik-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1507-1512
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

  • PDF

Analysis of the total system for production, transportation and utilization of hydrogen energy (수소 에너지 생산, 수송 및 이용에 대한 통합시스템 해석)

  • Oh, Byeong-Soo;Seo, Seog-Jin
    • Journal of Hydrogen and New Energy
    • /
    • v.9 no.1
    • /
    • pp.38-45
    • /
    • 1998
  • An energy crisis is expected in near future. Fossil fuel such as oil and natural gas has been used and will be no longer supplied enough to demand in the beginning of coming century. The use of the fuel makes a lot of environmental pollution to threaten human being's health especially in big cities and produces a lot of $CO_2$ to make green house effect of the earth. It is the time to use clean fuel such as hydrogen to prevent the expected energy crisis and the pollution. A new engine such as fuel cell can be used instead of the conventional internal combustion engine with 2 to 3 times higher efficiency of the conventional engine. The fuel cell uses hydrogen and oxygen and produces electric energy and pure water, which is a calm engine without air pollution. In big cities the city buses and the taxies powered by hydrogen fuel cells are suggested to be operated for clean environment. A model of the total energy system for production, transportation and utilization of hydrogen is calculated.

  • PDF

Optimization of 150kW Cogeneration Hybrid System (150kW급 열병합발전 하이브리드 시스템 최적화 연구)

  • Choi, Jae-Joon;Kim, Hyuk-Joo;Jung, Dae-Heon;Park, Hwa-Choon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.340-344
    • /
    • 2008
  • The importance of the more efficient cogeneration system is emphasized. Also the more clean energy is needed at recent energy system. The cogeneration system using Lean burn engine is more preferred to the system using Rich burn engine because of the electrical efficiency. Although the cogeneration system using Lean burn engine is economically preferred, because of the NOx emission level, the system using Rich burn engine with 3-way catalyst can only be used in Korea. The NOx regulation level is 50ppm at oxygen level 13%. The cogeneration hybrid system using Lean burn engine is up to be optimized because of the large amount of the extra-fuel at the after-burner system. The after-burner system at different concept was applied. The reduction time for the activation temperature of the DeNOx catalyst was achieved by making a hole between the combustor and boiler. Because of the lowered fuel consumption, the lowered temperature level was optimized by blocking the hole of the boiler The optimized cogeneration hybrid system consumes $76Nm^3/h$ LNG to produce 150kW electricity compared to before optimization $103Nm^3/h$ LNG. The system was accurately evaluated and the result is following ; 90% total efficiency, below 10 ppm NOx, 50ppm CO, 25ppm HC. The cogeneration hybrid system can meet the current NOx level and exhaust gas regulation. It can achieve the clean combustion gas and efficient cogeneration system.

  • PDF

The Utility Power Factor Control system of Photovoltaic Power Generation System

  • Koh Kang-Hoon;Lee Hyun-Woo;Suh Ki-Young;Taniguchi Katsunori
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.673-676
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel, which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.