• 제목/요약/키워드: Air circulation

검색결과 543건 처리시간 0.029초

체외순환중 발생한 대량 공기전색에 대한 상공대정맥을 통한 일시적역관류 -치험 2예-

  • 이재성
    • Journal of Chest Surgery
    • /
    • 제19권4호
    • /
    • pp.543-548
    • /
    • 1986
  • Massive air embolism during cardiopulmonary bypass is uncommon but serious and often lethal complication. Following this catastrophic event, the immediate institution of retrograde arterial blood perfusion via superior vena cava was made to remove air emboli from cerebral circulation. This method was performed by removing the arterial perfusion line from aortic cannula and connecting it to superior vena caval cannula. Then, retrograde perfusion at a flow rate of 2Umin via superior vena cava was carried out for 3 minutes. After air returning from the aortic cannula was identified, each line was connected to the cannulae primarily. In 2 cases who had massive air emboli due to air pumping into arterial line, the postoperative complete recovery resulted from this technique, which was used in conjunction with other therapy postoperatively.

  • PDF

천장복사냉방의 온열쾌적성 평가에 관한 연구 (Evaluation of Thermal Comfort in Ceiling Cooling System)

  • 이주연
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.287-293
    • /
    • 2008
  • The purpose of this study was to clarify the effects of air and ceiling temperatures on a type of ceiling cooling system that involves cool water circulation. The experiment is conducted in summer. The subjects (11 young females) are exposed to the following conditions: combinations of air temperatures $(27^{\circ}C,\;29^{\circ}C,\;31^{\circ}C)$ and ceiling temperature of $(22.7^{\circ}C,\;23.7^{\circ}C,\;24.7^{\circ}C)$ in still air and RH 50%. The following results were obtained; the thermal sensation vote is neutral at a mean skin temperature of $34.5^{\circ}C$. The ceiling temperature affected different parts of the body. For example, the forehead, scapula and abdomen produced different skin temperatures. Thermal comfort vote was rated as comfortable at high temperature environment. The satisfaction from the ceiling temperature was valued comfortable zone in this experiment. Mean skin temperature showing higher thermal neutrality temperature than existing studies for floor and wall radiation cooling results.

대기오염물질의 장거리 수송과 열적저기압의 관계 (Relationship between Thermal Low and Long-Range Transport of Air Pollutants)

  • 이화운;김유근;김해동;정우식;현명숙
    • 한국환경과학회지
    • /
    • 제10권2호
    • /
    • pp.143-151
    • /
    • 2001
  • The atmospheric conditions and the transport mechanism of long-range transport of air pollutants from coastal area to inland area were investigated using regular meteorological data and air pollution data obtatined from the southeastern area of Korea. Daytime temperature over the inland area(Taegu) was higher than that over the coastal area(Pusan) and the temperature difference of about 5~6$^{\circ}C$ when the thermal low most fully developed and the sea level pressure over Taegu was lower than that over Pusan by about 4~5hPa at that time. Therefore this low pressure appeared to the thermally induced low. Air mass polluted from the coastal area during the morning period was transported inland area, at first by the sea breeze and by the large scale wind system toward the thermal low generated in the mountainous inland region. This was explained by the fact that the concentration of air pollutants over Taegu increased throughtout the late afternoon.

  • PDF

분배계통에 따른 지하주차장 환기설비 성능의 예측

  • 김경환;이재헌;오명도;김종필
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.982-992
    • /
    • 2001
  • In this paper, the performance of ventilation equipments in enclosed parking garages were investigated for several air distribution systems by numerical method. Air change effectiveness of the non-mixing system was 0.42. It meant that more supply air as much as the design supply air was needed to maintain good indoor air quality. In the high speed nozzle ventilating system which is most expensive one, air change effectiveness was 0.54. Therefore this system satisfied to ventilation design. In the jet fan ventilating systems, air change effectiveness for jet fan ventilating system-A with 18 jet fans and jet fan ventilating system-B with 6 jet fans in circulation mixing arrangement were 0.565 and 0.42 respectively. Jet fan ventilating system-C with 6 jet fans in transport mixing arrangement was 0.535. Jet fan ventilating system-A and jet fan ventilating system-C met the ventilation design. But velocity in jet fan ventilating system-A was over 2.0m/s which is inappropriate in human comfort. Therefore this system is not proper to ventilation. Jet fan ventilating system-C was the optimum one for enclosed parking garages among 5 systems examined in this paper.

  • PDF

순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석 (Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer)

  • 이공훈;김욱중;이상열
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.

날개 형상에 따른 HVLS의 성능에 관한 연구 (AN INVESTIGATION ON HVLS FAN PERFORMANCE WITH DIFFERENT BLADE CONFIGURATIONS)

  • ;허남건;김영주;강현욱
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.80-85
    • /
    • 2014
  • High-volume low-speed (HVLS) fans are one category of ceiling fan installed in large enclosings such as warehouses, large barns and health clubs in order to generate comfortable air circulation. As a rotary blade, aerodynamic performance of a HVLS fan is predominantly related to its airfoil(s), and the pitch and twist angles. This paper first, investigates the effects of airfoil on the performances of three different HVLS fans with NACA 5414, 6413 and 7415 airfoils. The fans have six untwisted blades with the diameter of 6 m and rotate at 60 RPM. The blades pitch angels are $12^{\circ}$, $12^{\circ}$ and $13^{\circ}$, respectively. The results are presented in the form of the aerodynamic forces and moments, volumetric flow rate and streamlines. Regarding the volumetric flow of air, the results show that the model with NACA 7415 has the best performance. Hence, two other HVLS fans with the same airfoil but, with four and five blades are studied in order to investigate the effects of number of blades. From the point of view of air circulation still the six-bladed fan is the best one; however, the five-bladed fan is more efficient in power consumption.