• 제목/요약/키워드: Air change rates

검색결과 159건 처리시간 0.026초

울산지역 초등학교 학생에서 대기중 꽃가루 비산 수준과 흡입 알레르겐 감작률과의 관련성 (Association Between Airborne Pollen Counts and Sensitization Rate in Elementary School Children in Ulsan)

  • 오연서;최승원;오인보;이지호;심창선;방진희;김양호
    • 한국환경보건학회지
    • /
    • 제46권6호
    • /
    • pp.735-749
    • /
    • 2020
  • Objectives: The aim of this study was to investigate airborne pollen counts, inhalant allergen sensitization rate, and allergic disease prevalence among elementary school children in Ulsan, South Korea during 2012-2018. Methods: Burkard samplers for pollen were installed on rooftops in suburban and urban areas in Ulsan. A 24-hour sampling of airborne allergens was conducted six days/week from January 1, 2013 to November 31, 2018. Skin prick tests were done with a total of 4,246 primary school students residing in urban and suburban areas in 2012, 2014, 2016, and 2018. This study examined sensitization to 20 major inhalant allergens. Results: The highest monthly counts of airborne pollen were observed in April and September each year. Among the pollen identified over the six years, pine showed the highest pollen counts (44.3%), followed by oak (22.3%), alder (6.3%) and Japanese hops (4.3%). Tree pollen predominated from March to June, and weed pollen predominated from August to October. Higher sensitization rates for inhalant allergens were observed in Dermatophagoides farinae (42.4%), Dermatophagoides pteronyssinus (43.6%), cat fur (12.1%), birch (9.9%), oak (9.6%), and alder (8.7%). The inhalant allergen sensitization rate was highest in the group with comorbidity (asthma and/or rhinitis and atopic dermatitis), and respiratory allergic disease (asthma and/or rhinitis) was higher than that of atopic dermatitis. Conclusion: Both the counts of tree pollen in the air and the sensitization rate for tree pollen were high in Ulsan. The temporal change in respiratory allergic diseases was similar to that for the sensitization rate of tree pollen, such as oak. In the future, it is considered that additional continuous research on various inhalant allergens and pollen should be conducted.

소형 목재인공건조실에 있어서 공기순환속도가 목재건조율에 미치는 영향 (Effect of Air Circulation Velocity on the Rate of Lumber Drying in a Small Compartment Wood Drying Kiln)

  • 정병재
    • Journal of the Korean Wood Science and Technology
    • /
    • 제2권2호
    • /
    • pp.5-7
    • /
    • 1974
  • 본 논문은 필자가 미국 미쉬간대학에 유학중 실시된 연구로서 동대학 목재가공학과에 설치된 소형 목재인공건조장치를 사용하여 일정한 건조조건(건구 온도 $150^{\circ}F{\risingdotseq}65.5^{\circ}C$, 습구온도 $1250^{\circ}F{\risingdotseq}51.7^{\circ}C$, 관계습도 48%, 평형함수율 6.9%)하에 공기 순환속도를 매분당 250ft., 400ft, 및 650ft.로 변경할 때 얻어지는 건조속도를 측정하고, 시간당 건조율을 산출하여 비교 검토한 것이다. 본 실험에 사용한 수종은 북미산소나무 Northern white pine (Pinus strobus L.)로서 시편의 크기는 길이 60cm, 넓이 12.5mm(5in.), 두께 18.7mm(3/4in.)이며 공시목의 표면은 증발조건을 균일히 하기 위하여 포삭하였으며, 마구리(end grain)에는 end coating 하였다. 또한 공기순환속도 측정은 상기대학에 비치된 velometer를 사용하였다. 1. 목재의 섬유포화점(함수율 30%) 이상에 있어서 공시목의 건조율은 건조실내 공기순환속도의 증가에 따라서 증가된다. 즉 공시목의 건조율 증감은 공기 순환속도에 대략 비례한다. 그러나 섬유포화점 이하에 있어서는 공기순환속도의 증강은 건조율 증감에 거의 영향을 이치지 아니한다(그림 1, 2 참조). 2. 실험한 건조조건하에 있어서는 공시목의 초기 함수율이 높을수록 높은 건조율을 얻을 수 있다. 즉 공시목의 초기 함수율(MC30% 이상)이 동일하지 아니한 경우에도 공기순환속도를 증가하면 건조 최종기에 있어서 비교적 빨리 대체로 같은 함수율의 공시목을 얻을 수 있다(실험한 초기 함수율, 건조조건 및 공기순환 속도등은 심한 건조 결함을 유발하지 아니하였음). 3. 본연구 결과에 의하면 공시목의 건조율은 섬유포화점(대략 MC30%)에 있어서 현저한 변화를 나타내고 있다. 즉 공시목의 함수율에 대한 건조율 곡선은 그림 3으로 표시된 바와 같이 섬유포화점 이상에 있어서는 건조율 곡선은 X축(MC)에 대하여 요(凹)형(concave)을 나타냈는데, 섬유포화점 이하의 함수율 범위 30%에서 20%에 있어서는 건조율 곡선은 X축에 대하여 철(凸)형(convex)을 나타냈으며 함수율 20% 이하에 있어서는 재차 심한 요(凹)형을 나타내고 있음을 알 수 있다. 이와감은 결과를 요약표시한 원문 그림4에 있어서, 건조율 곡선의 반곡점은 대략 섬유포화점인 MC 30%와 MC 20%에 위치하고 있음을 알 수 있다. 이와같이 섬유 포화점으로 알려져 있는 MC 30%와 20%에 있어서 건조율이 급변하는 반곡점 즉 한계점을 표시하는 것은 다음과 같은 야유에 의한 것으로 고려된다. 즉 세포막에 흡수된 결합수의 증발은 세포강, 세포간격 및 기타의 미세한 공간에 존재하는 자유수의 증발보다 훨씬 곤란하므로, 함수율 30%에서 20%의 범위에 있어서는 철(凸)형을 나타낸다. 즉 함수율 30%에서 20% 의 범위에 있에서 세포막의 모세관 응축수(capillary-condensed water)의 증발은 대략 동일한 감소율을 나타내나, 공시목의 함수율이 20%에 접근됨에 따라서 한층 강한 결합상태하에 있는 수분(표면 결합수 및 그 부근에 있는 수분)이 증발하게 되나, 그와 같은 수분의 증발은 한층 곤란하므로 함수율 20% 이하에 있어서 건조율곡선은 재차 요(凹)형을 표시하는 것으로 사료된다. 이상의 관계를 요약 표시한 원문 그림 4에 있어서, 반곡점을 가지지 아니한 점선 곡선 AC 와 2개의 반곡점을 가지는 실선곡선 BD를 비교하면, BD곡선은 AC곡선보다 함수율범위 30%에서 20%에 있어서 그 건조율은 현저히 감소되고 또한 D점을 반곡점으로 해서 그 건조율은 가일층 감소되고 있음을 알 수 있다. 이상을 요약하면 생재에서 함수율 30%(섬유포화점)까지는 큰 건조율을 표시하니 함수율 범위 30%에서 20%에 있어서는 그 건조율은 점감되고 함수율 20% 이하에 있어서는 그 건조율은 현저히 감소됨을 표시한다.

  • PDF

Ecosysteme de I′Etang de Berre (Mediterranee nord-occidentale) : Caracteres Generales Physiques, Chimiques et Biologiques

  • Kim, Ki-Tai
    • 환경생물
    • /
    • 제22권2호
    • /
    • pp.247-258
    • /
    • 2004
  • Climatological, hydrological and planktonical research studies, measurements of primary production and photosynthetic efficiency from December 1976 to December 1978 have been carried out in two brackish lakes: Lake Etang de Berre and Lake Etang de Vaine located in the French Mediterranean coast, in the region of Carry-le-Rouet located on the north-west Mediterranean near Marseilles, and in fresh water inflows from 4 Rivers (Touloubre, Durance, Arc, Durancole) to Lake Etang de Berre. Physico-chemical parameters were measured for this study: water temperature, salinity, density, pH, alcalinity, dissolved oxygen (% saturation), phosphate, nitrate, nitrite, silicate etc. Diverse biological parameters were also studied: photosynthetic pigments, phaeopigments, specific composition and biomass of phytoplankton, primary pelagic production etc. Climatical factors were studied: air-temperature, solar-radiation, evaporation, direction (including strength) of winds, precipitation and freshwater volume of the four rivers. The changes in Lake ‘Etang de Berre’ ecosystem depend on the quality of the water in the Durance River, and on the effects of seawater near the entrance of the Caronte Canal. The water quality of the lake varies horizontally and vertically as a result of atmospheric phenomena, maritime currents and tides. The distribution of water temperatures is generally heterogeneous. Southeasterly winds and the Northeasterly Mistral wind are important in the origins of circulated and mixed water masses. These winds are both frequent and strong. They have, as a result, a great effect on the water environment of Lake Etang de Berre. In theory, the annual precipitation in this region is well over eight times the water mass of the lake. The water of the Durance River flows into Lake Etang de Berre through the EDF Canal, amounting to 90% of the precipitation. However, reduction of rainfall in dry seasons has a serious effect on the hydrological characteristics of the lake. The temperature in the winter is partially caused by the low temperature of fresh water, particularly that of the Durance River. The hydrological season of fresh and brackish water is about one month ahead of the hydrological season of sea water in its vicinity. The salinity of Lake Etang de Berre runs approximately 3$\textperthousand$, except at lower levels and near the entrance to the Caronte Canal. However, when the volume of the Durance River water is reduced in the summer and fall, the salinity rises to 15$\textperthousand$. In the lake, the ratio of fresh water to sea water is six to one (6:1). The large quantities of seston conveyed by rivers, particularly the Durance diversion, strongly reduce the transparency in the brackish waters. Although the amount of sunshine is also notable, transparency is slight because of the large amount of seston, carried chiefly by Tripton in the fresh water of the Durance River. Therefore, photosynthesis generally occurs only in the surface layer. The transparency progressively increases from freshwater to open seawater, as mineral particles sink to the bottom (about 1.7kg $m^{-2}a^{-1}$ on the average in brackish lakes). The concentration of dissolved oxygen and the rate of oxygen saturation in seawater (Carry-le-Rouet) ranged from 5.0 to 6.0 $m\ell$ㆍ.$1^{-1}$, and from 95 to 105%, respectively. The amount of dissolved oxygen in Etang de Berre oscillated between 2.9 and 268.3%. The monographs of phosphate, nitrate, nitrite and silicate were published as a part of a study on the ecology of phytoplankton in these environments. Horizontal and vertical distributions of these nutriments were studied in detail. The recent diversion of the Durance River into Lake Etang de Berre has effected a fundamental change in this formerly marine environment, which has had a great impact in its plankton populations. A total of 182 taxa were identified, including 111 Bacillariophyceae, 44 Chlorophyceae, and 15 Cyanophyceae. The most abundant species are small freshwater algae, mainly Chlorophyceae. The average density is about $10^{8}$ cells $1^{-1}$ in Lake Etang de Berre, and about double that amount in Lake Etang de Vaine. Differences in phytoplankton abundance and composition at the various stations or at various depths are slight. Cell biovolume V (equivalent to true biomass), plasma volume VP (‘useful’ biomass) and, simultaneously. the cell surface area S and S/V ratio through the measurement of cell dimensions were computed as the parameters of phytoplankton productivity and metabolism. Pigment concentrations are generally very high on account of phytoplankton blooms by Cyanophyceae, Chlorophyceae and Cryptophyceae. On the other hand, in freshwaters and marine waters, pigment concentrations are comparatively low and stable, showing slight annual variation. The variations of ATP concentration were closely related to those of chlorophyll a and phytoplankton blooms only in marine waters. The carbon uptake rates ranged between 38 and 1091 mg$Cm^{-2}d^{-1}$, with an average surface value of 256 mg; water-column carbon-uptake rates ranged between 240 and 2310 mg$Cm^{-2}d^{-1}$, with an average of 810, representing 290 mg$Cm^{-2}$, per year 45 000 tons per year of photosynthetized carbon for the whole lake. Gross photosynthetic production measured by the method of Ryther was studied over a 2-year period. The values obtained from marine water(Carry-le-Rouet) ranged from 23 to 2 337 mg$Cm^{-2}d^{-1}$, with a weighted average of 319, representing about 110 gCm$^{-2}$ per year. The values in brakish water (Etang de Berre) ranged from 14 to 1778 mg$Cm^{-2}d^{-1}$, with a weighted average of 682, representing 250 mg$Cm^{-2}$ per year and 38 400 tons per year of photosynthesized carbon for the whole lake.

실외 실험적 온난화 처리가 굴참나무 묘목의 생장에 미치는 영향 (Effects of Experimental Warming on Growth of Quercus variabilis Seedlings)

  • 이선정;한새롬;윤태경;정혜근;노남진;조우용;박찬우;고수인;한승현;손요환
    • 한국산림과학회지
    • /
    • 제101권4호
    • /
    • pp.722-728
    • /
    • 2012
  • 기후변화는 생태계 구조와 기능에 영향을 미치고, 특히 기온 상승은 광합성과 생장기간을 변화시켜 식물의 생장에 영향을 줄 것으로 예상된다. 본 연구는 실외 실험적 온난화가 굴참나무(Quercus variabilis) 묘목의 생장에 미치는 영향을 알아보고자, 1-0 묘목을 2010년 4월에 식재하고, 2010년 11월부터 적외선등을 이용하여 온난화 처리구의 기온을 대조구보다 $3^{\circ}C$ 증가시켰다. 2011년 3월과 2012년 6월에 묘고와 근원경을 각각 측정하였고, 2011년과 2012년 3월에 지상부 및 지하부 생물량을 각각 조사하였다. 묘고 및 근원경은 온난화 처리구에서 대조구보다 높았으며, 2011년 3월 근원경을 제외하고 차이는 모두 통계적으로 유의하였다. 굴참나무 묘목의 생장량(mm)은 온난화 처리구 (묘고: $529{\pm}30$, 근원경: $5.6{\pm}0.5$)에서 대조구(묘고: $464{\pm}28$, 근원경: $4.5{\pm}0.4$)보다 높았으며, 근원경 생장량에서만 통계적으로 유의한 차이가 나타났다. 생물량 증가량(g/year)의 경우도 온난화 처리구(총 생물량: $36.88{\pm}6.52$, 지상부: $11.91{\pm}3.44$, 지하부: $24.97{\pm}3.73$)에서 대조구(총 생물량: $30.59{\pm}5.51$, 지상부: $8.73{\pm}1.66$, 지하부: $21.86{\pm}3.88$)보다 높았으나, 온난화 처리구와 대조구간 통계적으로 유의한 차이를 보이지 않았다. 온난화 처리에 따른 굴참나무 묘목의 생장 및 생물량 증가 경향은 생장기간과 봄철 순광합성률 증가와 관련이 있을 것으로 추정된다.

분포형 수문모형(VELAS)을 이용한 홍성 양곡리 일대 지하수 함양량 평가 (Groundwater Recharge Evaluation on Yangok-ri Area of Hongseong Using a Distributed Hydrologic Model (VELAS))

  • 하규철;박창희;김성현;신에스더;이은희
    • 자원환경지질
    • /
    • 제54권2호
    • /
    • pp.161-176
    • /
    • 2021
  • 본 연구는 과거와 미래의 연 단위보다 상세한 일단위 지하수 함양량을 평가하기 위해, 분포형 수문모형중의 하나인 VELAS를 이용하여 물수지에 근거한 수문요소별 변동을 분석하고자 하였다. 가뭄에 매우 취약한 충남 홍성군 서부면 양곡리 일대 소유역을 대상으로, VELAS의 입력자료인 수치표고모델, 식생도, 경사도 등의 공간특성자료를 구축하였고, 기후자료는 기상청의 일별 대기온도, 강수, 평균풍속, 상대습도 등의 자료를 공간적으로 보간하였다. 연구지역의 과거 2001년부터 2018년까지 18년 동안 일단위 물수지 분석결과, 연간 강수량은 799.1~1750.8 mm로 평균 1210.7 mm이고, 지하수 함양량은 28.8~492.9 mm로 평균 196.9 mm로 분석되었다. 연 강수량 대비 지하수 함양률은 최소 3.6%에서 최대 28.2%로 변동폭이 매우 크고, 평균 함양률은 14.9%였다. 미래 기후변화 RCP 8.5시나리오에 의한 2019년부터 2100년까지의 일단위 물수지 분석결과, 연간 강수량은 572.8~1996.5 mm(평균 1078.4 mm)이고, 지하수함양량은 26.7~432.5 mm, 평균 174.6 mm(평균 강수량의 16.2%)로서 과거보다 다소 증가하였다. 미래 연간 지하수 함양률은 최소 2.8%, 최대 45.1%, 평균 18.2%로 분석되었다. 물수지를 구성하는 요소들은 강수량과의 상관성이 잘 나타나며, 일단위보다는 연단위로 갈수록 그러한 상관성이 뚜렷했다. 다만, 증발산량은 강수량보다는 기온 등 다른 기후요소에 더 영향을 받는 것으로 보인다. 본 연구를 통해 산정된 연단위 보다 상세 시간 단위에서의 지하수함양량은 가뭄 또는 홍수 등 시기별로 강수량 변동이 심한 경우 지하수개발과 관리에 활용될 수 있는 기초자료를 제공할 수 있을 것으로 기대된다.

지구온난화에 따른 우리나라 벼농사지대의 생산성 재평가 (Evaluation of Site-specific Potential for Rice Production in Korea under the Changing Climate)

  • 정유란;조경숙;이변우
    • 한국농림기상학회지
    • /
    • 제8권4호
    • /
    • pp.229-241
    • /
    • 2006
  • 본 연구에서는 실측 일기상자료 대신 예측 기후평년 값을 적용하여 기후변화와 그에 상응한 벼 작황의 지리적 분포양상을 복원함으로써 지구온난화에 따른 우리나라 벼농사지대의 생산성을 재평가하였다. 기상청 56개 지점 종관자료(일 최고/최저 기온의 월별 평균값)를 1971-2000년 30년 단위로 수집하여 270m 해상도의 수치기후도를 작성하고, 벼논픽셀에 해당되는 기후자료를 추출하였다. 동일한 시군에 속하는 벼논픽셀의 기후자료를 평균함으로써 시군단위의 '벼논맞춤형 기후자료'를 준비하였다. 같은 방법으로 기상연구소에서 제작한 2011-2100년 기간의 3개 평년(2011-2040, 2041-2070, 2071-2100) 기후시나리오에 근거하여 해당 평년의 기후자료를 추정하였다. 농촌진흥청의 정밀토양도로부터 해당 픽셀의 토성과 토심정보를 검색하고 이를 토대로 유효수분 조견표에 의해 토양자료를 준비하였다. 자포니카형 벼의 특성을 갖도록 개조한 벼 생육모형(CERES-Japonica)에 이들 자료를 입력하고 조생종(오대벼), 중생종 (화성벼), 만생종 (동진벼)의 생육을 모의하였다. 시군 공간평균을 기준으로 3품종 모두 가까운 미래(2011-2040년)에는 출수기가 일주일 정도 빨라지고, 먼 미래(2071-2100년)에는 최대 20일 까지 단축될 수 있다. 생리적 성숙기는 3품종 모두 가까운 미래(2011-2040년)에는 15일 정도 단축되고, 먼 미래(2071-2100년)에는 최대 한달까지도 빨라질 수 있어 출수기에 비해 단축정도가 심하다. 평야지 수량의 경우 조생종인 오대벼는 10a당 6-25%, 중생종 화성벼는 3-26%, 만생종 동진벼는 3-25%까지 감소하였다. 하지만 산간지역에서는 발육속도가 빨라지고 수량이 증가하거나 큰 변화가 없는 곳도 많아 온난화조건에서도 지역별 정밀기후 추정과 이에 근거한 최적품종의 선택, 이앙기 및 수확기 등 생육기간의 조절이 온난화 대응기술로서 유효할 것으로 기대된다.

참깨의 발아특성(發芽特性)에 관(關)한 연구(硏究) (Studies on the Germination Characteristics of Sesame (Sesamum indicum L.))

  • 김충수
    • 농업과학연구
    • /
    • 제10권1호
    • /
    • pp.28-60
    • /
    • 1983
  • 본(本) 연구(硏究)는 참깨종자(種子)의 발아(發芽)에 미치는 온도(溫度), 수분(水分), 산소(酸素) 및 관(光) 등(等)의 외적(外的) 조건(條件)의 영향(影響) 발아진행중(發芽進行中)의 종자내(種子內) 물질변화(物質變化)를 구명(究明)하고져 수행(遂行) 되었던 바 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. $35^{\circ}C$부터 $5^{\circ}C$ 간격(間隔)으로 $20^{\circ}C$까지는 평균(平均) 95.8~97.2%의 발아율(發芽率)을 보였고 이들 온도간(溫度間)에는 평균발아율(平均發芽率)의 유의차(有意差)가 인정(認定)되지 않았으나 $15^{\circ}C$에서는 발아율(發芽率)의 급격(急激)한 감소(減少)를 보여 평균(平均) 32.2% 발아(發芽)되었고 이때 변이계수(變異係數)는 77%였다. 2. 온도(溫度)에 따르는 발아소요일수(發芽所要日數)는 $35{\sim}25^{\circ}C$에서 평균(平均) 1.16~1.64일(日)이었으며 $20^{\circ}C$에서는 3.07일(日)이었고 $15^{\circ}C$에서는 10.40일(日)이었다. 3. 발아율(發芽率) 및 발아소요일수(發芽所要日數)를 감안(勘案)할때 $15^{\circ}C$가 참깨종자(種子)의 발아한계온도(發芽限界溫度)였으며 참깨 종자(種子)의 저온발아성(低溫發牙性) 검정(檢定)에 가장 효과적(效果的)인 온도(溫度)로 고려(考慮)되었다. 4. Shirogoma, Turkey등(等)이 가장 저온발아성(低溫發牙性)이 높았고 수원(水原)29호(號), 내복, IS58이 그 다음이었으며, 70~80%의 비교적(比較的) 높은 발아율(發芽率)을 보이는 품종(品種)들이 매포, 수원(水原)14호(號), 김포, 문덕, 해남이었는데, 이들 저온발아성(低溫發牙性)이 비교적(比較的) 높은 품종(品種)은 전공시품종(全供試品種)(90품종(品種))의 10%였으며 이들중 70%는 국내품종(國內品種)이었다. 5. $12^{\circ}C$에서 Shirogoma만 50% 이상(以上)의 발아율(發芽率)을 보였으며 대부분(大部分) 20%미만(未滿)의 낮은 발아율(發芽率)을 보였는데 파종후(播種後) 18일(日)에 온도(溫度)를 $27^{\circ}C$로 상승(上昇)시켰던바 2일이내(日以內)에 전품종(全品種)에서 90% 이하(以上)의 발아율(發芽率)을 보였으며 변온처리(變溫處理)에 따르는 품종간(品種間) 발아율간(發芽率間)에는 유의차(有意差)가 없었고 발아소요일수(發芽所要日數) 간(間)에는 청송, 의상천, 산동, 마산 등은 현저(顯著)히 소요일수(所要日數)가 길었다. 6. 발아(發芽)에 필요한 흡수율(吸水率)은 $25^{\circ}C$적습하(適濕下)에서 48%내지 62%로서 품종간(品種間)에 현저(顯著)한 차이(差異)를 나타내었다. 또한 치상후(置床後), 2시간에 발아(發芽)에 소요(所要)되는 전체 수분(水分)의 63% 정도가 흡수(吸收)되었다. 7. 포화수분하(飽和水分下)에서는 전공시품종(全供試品種)에서 평균발아율(平均發芽率)이 0.42%였고 -0.4bar에서는 64.8%였으며 -0.4~-5.5bar에서 가장 발아율(發芽率)이 높았고 이보다 토양수분(土壤水分)이 부족(不足)할 경우 발아율(發芽率)은 거의 직선적(直線的)인 감소(減少)를 보였다. 8. 10개(個) 공시품종중(供試品種中) 6개공시품종(個供試品種)에서는 5%의 산소하(酸素下)에서 발아(發芽)에 영향(影響)을 받지 않았으나 예천, PI158073, IS103, 의상천의 4품종(品種)은 산소농도(酸素濃度) 5%에서는 발아율(發芽率)이 64~91%로 저하(低下)되었다. 또한 무산소하(無酸素下)에서는 하배축(下胚軸)만 출현(出現)하였을뿐 자엽(子葉)의 출현(出現)은 없었으며 하배축(下胚軸) 출현(出現)은 IS103이 현저(顯著)히 낮았다. 9. 청송, Early Russian 및 수원(水原)9호(號)는 12시간(時間) 흡습(吸濕)시킨 후(後) 24시간(時間) 건조(乾燥)시킬때 청송만 27.5%의 발아율(發芽率)을 보였고 수원(水原)9호(號) 및 Early Russian은 전혀 발아(發芽)되지 않았으며 IS103은 4시간 흡습후(吸濕後) 24시간(時間) 건조시(乾燥時) 발아율(發芽率)이 감소(減少)되었는데 24시간(時間) 흡습후(吸濕後) 24시간(時間) 건조시(乾燥時)에도 32.5%의 발아율(發芽率)을 보였다. 10. 발아(發芽)의 진행(進行)에 따라 종자내(種子內) 당함량(糖含量)은 급격(急激)한 증가(增加)를 보였으나 전분함량(澱粉含量)은 현저(顯著)히 감소(減少)되었으며 ${\alpha}$-amylase의 활성도(活性度)는 점증(漸增)되었는데 이들 증감정도(增減程度)는 $25^{\circ}C$에 비해 $15^{\circ}C$에서는 현저(顯著)히 낮았다. 11. 발아(發芽)가 진전(進展)됨에 따라 종자(種子)의 지질함량(脂質含量)은 급격(急激)한 감소(減少)를 보였고 alkaline lipase의 활성도(活性度)는 특히 발아초기(發芽初期)에 더욱 급격(急激)한 증가(增加)를 보였는데 지질(脂質)의 감소정도(減少程度)와 alkaline lipase의 활성도(活性度) 증가정도(增加程度)는 $25^{\circ}C$에 비해 $15^{\circ}C$에서 현저(顯著)히 낮았다. 12. 6개공시품종중(個供試品種中) 4개공시품종(個供試品種)의 발아(發芽)에는 광파장(光波長)의 영향(影響)을 받지 않았으나 수원(水原)8호(號)는 600~650nm에서 IS103은 600~650nm, 500~550nn에서 현저(顯著)히 발아율(發芽率)이 저하(低下)되었으며 수원(水原)8호(號)는 600~760nm 및 500~560nm에서, IS103은 400~470nm 및 암흑상태(暗黑狀態)에서 높은 발아율(發芽率)을 보였다. 13. 100입중(粒重)이 무거운 종자(種子)에서 각(各) 품종(品種)의 발아율(發芽率)이 현저(顯著)히 높았으며 파종심도(播種深度) 4 cm 하(下)에서는 청송 및 Early Russian은 전혀 자엽(子葉)이 출현(出現)되지 않았던 반면(反面), 수원(水原)9호(號) 및 IS103은 각각(各各) 32.5 및 50%의 발아율(發芽率)을 보였다. 또한 참깨의 지상부(地上部), 지하부(地下部) 및 재배지토양(栽培地土壤) 추출물(抽出物)은 발아(發芽)에 전혀 영향(影響)을 미치지 않았다. 14. 무피복구(無被覆區)에 비해 흑색(黑色) 및 투명(透明) polyethylene film 피복구(被覆區)에서 발아율(發芽率)이 현저(顯著)히 높았고, 발아소요일수(發芽所要日數)는 현저(顯著)이 단축(短縮)되었으며 또한 초기생육(初期生育) 및 주당삭수와 주당수량(株當收量)이 현저(顯著)히 증가(增加)되었는데 polyethylene film의 종류간(種類間)에는 유의차(有意差)가 인정(認定)되지 않았으나 흑색(黑色)polyethylene film보다는 투명(透明) polyethylene film이 약간(若干) 더 효과적(效果的)인 경향(傾向)이었다. 15. 심천, 청송, 수원(水原)9호(號), PI158073 및 IS103은 수분흡수율(水分吸收率)이 현저(顯著)히 낮았고 흡습후(吸濕後) 종자중(種子重)의 증가(增加)는 수원(水原)8호(號), 수원(水原)26호(號), Orotall 및 의상천이 현저(顯著)히 컸다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF