• 제목/요약/키워드: Air change per hour

검색결과 33건 처리시간 0.026초

초·중·고등학교의 이산화탄소 농도 및 환기량 평가 (Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools)

  • 최영태;허정;박진현;김은채;류현수;김동준;조만수;이채관;이종대;양원호
    • 한국환경보건학회지
    • /
    • 제46권3호
    • /
    • pp.344-352
    • /
    • 2020
  • Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

환기방식별 실내 환기효율 분석에 관한 실험적 연구 (An Experimental Analysis of Ventilation Effectiveness using Tracer Gas)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.260-266
    • /
    • 2006
  • A tracer gas technique based on ASTM Standard E741-83 was used to measure ventilation performances in a model chamber ($0.84m{\times}0.68m{\times}0.7m$) with an exhaust fan and a supply fan. Experiments were performed for the ventilation effectiveness on three types of mechanical ventilation systems. For all cases. higher ventilation effectiveness was found in the type to ventilation system due to shorter residual time of air compared to type 1 and type 3.

침실 공기질 개선을 위한 강제 환기횟수에 관한 연구 (A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

농업지역(밭) 암모니아 등 대기오염물질 계절별 모니터링 연구 (Study on the Emission Characteristics of Air Pollutants from Agricultural Area)

  • 김민욱;김진호;김경식;홍성창
    • 한국환경농학회지
    • /
    • 제40권3호
    • /
    • pp.211-218
    • /
    • 2021
  • BACKGROUND: Fine particulate matter (PM2.5) is produced by chemical reactions between various precursors. PM2.5 has been found to create greater human risk than particulate matter (PM10), with diameters that are generally 10 micrometers and smaller. Ammonia (NH3) and nitrogen oxides (NOx) are the sources of secondary generation of PM2.5. These substances generate PM2.5 through some chemical reactions in the atmosphere. Through chemical reactions in the atmosphere, NH3 generates PM2.5. It is the causative agent of PM2.5. In 2017 the annual ammonia emission recorded from the agricultural sector was 244,335 tons, which accounted for about 79.3% of the total ammonia emission in Korea in that year. To address this issue, the agricultural sector announced the inclusion of reducing fine particulate matter and ammonia emissions by 30% in its targets for the year 2022. This may be achieved through analyses of its emission characteristics by monitoring the PM2.5 and NH3. METHODS AND RESULTS: In this study, the PM2.5 concentration was measured real-time (every 1 hour) by using beta radiation from the particle dust measuring device (Spirant BAM). NH3 concentration was analyzed real-time by Cavity Ring-Down Spectroscopy (CRDS). The concentrations of ozone (O3) and nitrogen dioxide (NO2) were continuously measured and analyzed for the masses collected on filter papers by ultraviolet photometry and chemiluminescence. CONCLUSION: This study established air pollutant monitoring system in agricultural areas to analyze the NH3 emission characteristics. The amount of PM2.5 and NH3 emission in agriculture was measured. Scientific evidence in agricultural areas was obtained by identifying the emission concentration and characteristics per season (monthly) and per hour.

RTS-SAREK을 이용한 사무용 건물의 나이트 퍼지 성능 평가 (Night Purge Evaluation Using the RTS-SAREK in Office Buildings)

  • 신동신;박성근;박영수;박지수;이진영
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.633-638
    • /
    • 2015
  • This study evaluates the capacity of night purging in office buildings to reduce the cooling load. RTS-SAREK is used to estimate the performance of night purging on the steady state. To overcome steady state RTS program limitations, we added unsteady heat transfer equations. When the ACH (Air Change per Hour) increases, the wall temperature decreases in both the steady and unsteady states. The unsteady heat transfer rate is different from the steady transfer rate, which validates the unsteady calculation. When ACH is low, the heat transfer rate increases continuously with time. When ACH becomes higher, the heat transfer rate increases and decreases with time. When ACH is quite high, there exists a large difference in the heat transfer rate between the steady and unsteady calculations, which emphasizes the importance of the unsteady calculation.

신한옥 침실 공간의 기밀성능 평가 연구 (A Study on the Airtightness Performance of New Han-ok Bedrooms)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

실내사무환경에서의 환경성담배연기(ETS) 중 지표물질에 관한 연구

  • 하권철;백남원;박동욱;윤충식
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 가을학술대회
    • /
    • pp.154-159
    • /
    • 2005
  • The markers for Environmental Tobacco Smoke(ETS) a.e necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment. The purpose of this research is to evaluate Indoor environment using the concentration of ETS and the correlations between markers(RSP, nicotine, 3-EP) and environmental conditions(smoking density, ventilation rate). The mean ACH(air change per hour) in smoking rooms showed non-compliance with ASHRAE standard value. The concentrations of RSP, 3-EP, nicotine showed log-normal distributions, and became different statistically depending on smoking condition(p<0.01). The geometric mean concentration of RSP in smoking room was 441.7 ${\mu}g/m^3$ that is far exceeded environmental standard(150 ${\mu}g/m^3$). The correlation coefficients between RSP and SI, 3-EP and SI, and Nicotine and SI were 0.67, 0.84, 0.74 respectively. The correlation coefficient between nicotine and 3-EP, Nicotine and RSP, and RSP and 3-EP were 0.76, 0.78, 0.57 respectively.

  • PDF

서울시내 PC방에서의 환경성담배연기(ETS) 농도에 관한 연구 (A Study on the Concentrations of Environmental Tobacco Smoke in PC Game Rooms in Seoul)

  • 황규석;백남원;하권철
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.43-49
    • /
    • 2003
  • ETS concentrations in the PC game rooms and factors affecting ETS concentrations were measured. Nicotine, 3-EP, respirable dust and UVPM were used as tracers for ETS. ETS concentrations are 2-3 times higher than those of other results. The concentration of ETS at the commercial district was higher than that of the residential district. The correlations between these tracers and SD/ ACH, a factor affecting to ETS concentration, were calculated. The correlation between 3-ethenylpyridine among tracers and SD/ACH was highest. The correlation between respirable dust and SD/ ACH was lowest. It was difficult to recommend respirable dust as a tracer of ETS.

공동주택에서 각 실 문의 개폐에 따른 환기 특성 연구 (A Study on the Effect of Open and Closed Room Doors on Apartment Ventilation Characteristics)

  • 최임규;김영일;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.469-474
    • /
    • 2008
  • The objective of this study is to propose basic design guidelines for more effective air ventilation system in apartments. It is well known that ventilation depends on whether the room doors are open or closed as well as people's living patterns. This study considers 84 ㎡-sized apartment which has extended living room without balcony. Ventilation of bathroom and kitchen is not considered. The height of the building, external air pressure and air infiltration through the windows are also neglected. The regulation on indoor air quality made it mandatory that the air change per hour be more than 0.7. Four models are suggested to study the effect of open and closed doors. Models 1 and 3 are open door types and models 2 and 4 are closed door types. The open types have 50 mm hole near the top of the door to substitute exhaust outlet. The ventilation effectiveness was evaluated by 3-dimensional numerical simulation using finite volume method by a commercial software. This work compares air flow, temperature of air, age of air and the efficiency of ventilation of apartments with wooden doors of bedroom 1 and 2, which are open or closed.

  • PDF

이산화티탄 광촉매 환기장치의 오염물질 저감 실험 (Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System)

  • 송용우
    • 토지주택연구
    • /
    • 제13권2호
    • /
    • pp.117-123
    • /
    • 2022
  • 본 연구는 대표적인 미세먼지와 실내유해물질인 질소산화물의 저감을 위해 이산화티탄 광촉매를 환기장치에 적용한 것으로 그 내용은 다음과 같다. 기존 연구는 실내에 자외선 적용의 한계로 인해 주로 건축자재에 광촉매 혼입을 통해 실외 자재를 대상으로 진행되었다. 자외선 실내 적용 한계를 극복하고자 기존 선행연구를 통해 확인된 이산화티탄 광촉매의 오염물질 분해 효과를 실내에 적용이 가능하도록 자외선램프의 설치가 가능한 반응장치를 설계 및 제작하였다. 해당 반응장치를 실내 환기장치에 적용하여 Mock-Up에 적용하였다. Mock-Up 실험은 그 체적을 시간당 1회, 5회 환기하는 풍량을 변화시켜 NOx 저감 성능을 확인하였다. 그 결과, 환기 풍량이 증가함에 따라 NOx 저감시간이 비례하여 감소되어 그 성능이 증가하는 것을 확인하였다. 해당 연구를 통해 오염물질 저감 효과를 가진 이산화티탄 광촉매의 실내 활용 방안과 그 성능을 확인할 수 있는 기초적인 연구 결과를 도출하였다.