• 제목/요약/키워드: Air cap

검색결과 102건 처리시간 0.022초

창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발 (Development of detachable air-cap module for improving the performance of windows)

  • 서범동;이행우;서장후;김용성
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.

수도권 지역별 목표대기질 달성을 위한 오염배출 삭감율 산정 연구 (An Estimation of Emission Reduction Rates to Achieve the Target Air Quality in Seoul Metropolitan Area)

  • 김정수;김지영;홍지형;정동일;반수진;박상남
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.1-13
    • /
    • 2007
  • This study was carried out to estimate the emission reduction rates for the regional allowable emissions by special measures to achieve the target air quality in Seoul Metropolitan Area (SMA). A modeling system was designed to validate the details in enforcement regulations set up by local governments based on the current status and plans for air quality improvement. Modeling system was composed of meteorological model (MM5), emission model (SMOKE), and air quality model (CMAQ). Predicted results by this system show quiet well not only daily air pollutants concentration but also the tendencies of wind direction, wind speed and temperature. To achieve the target air quality in Seoul Metropolitan Area (SMA), emission allowances are estimated by seasons and regions. Referring to the base year 2002, it was estimated that emission reduction rates to achieve the intermediate goal in 2007 were 14.2% and 16.6% for NOx and $PM_{10}$, respectively. It was also estimated that 52% of NOx and 48% of $PM_{10}$ reductions from the base year 2002 would be required to accomplish the air quality improvement goal of 22 ppb for $NO_2$, and $40mg/m^3$ for $PM_{10}$ in year 2014. To improve $NO_2$ and $PM_{10}$ concentration through emissions reduction policies, it was found that emissions reduction for the on-road mobile sources would be the most effective in SMA.

국내 이동오염원에서 발생되는 벤젠 배출량 산정 (Estimation of Benzene Emissions from Mobile Sources in Korea)

  • 이주형;차준석;홍지형;정동일;김지영
    • 한국대기환경학회지
    • /
    • 제24권1호
    • /
    • pp.72-82
    • /
    • 2008
  • Benzene is a very harmful and toxic compound known as human carcinogen by all routes of exposure. Owing to the risky feature of benzene, several countries such as Japan, UK and EU have established the ambient air quality standard and protect from that risk of it. Korea also has designated it as one of the criteria air pollutants and established the concentration limit ($5\;{\mu}g/m^3$) in the air and is going to apply the standard from 2010. Benzene is emitted from various sources such as combustion plants, production processes, waste treatment facilities and also automobiles. Mobile source is known as one of the major emission sources of benzene. In this study, we estimated the domestic emissions of benzene from mobile source and compared the results with those of advanced countries. Mobile source was divided into 2 categories, Le., on-road source and non-road source. The total emissions of benzene from mobile source were estimated as 3,106 tons/yr and 1,612 tons/yr was emitted from on-road source and 1,494 tons/yr was from non-road source. Emission ratio of benzene from on-road source showed that 80.0% was from passenger cars, 10.1% was from taxis, 7.2% was from light-duty vehicles, 2.5% was from heavy-duty vehicles and 0.2% was from buses. In the case of non-road source, the distribution showed that 66.3% was from construction machineries, 14.5% was from locomotives, 11.7% was from ships, 7.1% was from agriculture equipments and 0.5% was from aircrafts. The cold-start emissions were estimated as 942 tons/yr and this value was almost 1.5 times greater than that for hot engine emissions (608 tons/yr). In addition, the fuel-based distribution was 65.9%, 31.1% and 2.8% from gasoline, LPG and diesel vehicles, respectively. The emission ratio from mobile source occupied 65% and 30% of total benzene emissions in USA and UK, respectively. In case of Korea, the emission ratio of benzene from mobile source occupied 29% (15% from on-road source, 14% from non-road source) which showed similar value with UK.

저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과 (Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma)

  • 백남원;허성민;이일영
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

시멘트 산업부문 온실가스(CO2) 배출계수 산정 연구 (A Study on the Estimation of Emission Factors for Greenhouse Gas (CO2) in Cement Industry)

  • 송형도;홍지형;엄윤성;이수빈;김대곤;김정수
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.158-168
    • /
    • 2007
  • The cement industry is one of the energy intensive industries such as petrochemical and steel industry. The energy efficiency of cement industry is high comparing to oversea's cement industries due to the enforcement of energy conservation policies. The purpose of this study is estimate emission factors for greenhouse gas ($CO_{2}$) in cement industry. The results of field study, quicklime contained quantity of five factories were $0.64{\sim}0.65$. Measurement emission (15,382 ton/day) is 40% higher than process emission (8,929 ton/day) on the IPCC Guidelines (1996). Add to combustion emission on the lines of IPCC Guidelines (1996) is similar to the emission of this study. The emission factor of greenhouse gas ($CO_{2}$) were as follows the emission factor between $9.01E-01{\sim}2.15E-01\;ton/ton$ for $CO_{2}$. The result of this study is higher than emission factor of IPCC (0.51) but it is similar to U.S. EPA's (0.952).

수도권 사업장 대기총량제 시행에 따른 신·증설 사업장 허가기준 개발 연구 (A Study on the Permit Method for a New or an Enlarged Facilities According to the Implementation of Air Pollutant Emission-Cap Regulation in Metropolitan Area)

  • 김홍록;윤영봉;고병철;신원근;김동중;이명훈
    • 환경영향평가
    • /
    • 제16권4호
    • /
    • pp.301-310
    • /
    • 2007
  • For the improvement of air quality in the metropolitan area, Korea has enforced the air pollutant emission cap regulation from the 1st of July, 2007, and the companies that intend to install a new or an enlarged facility in the metropolitan area will be restricted. However, the current regulation on permission does not describe a standard of judgement distinctly. In this study, therefore, a method of permission on the installation of a new or an enlarged facility was developed by supplementing the law in force based on the foreign cases. To develop a specific permit regulation and procedure, the developed nations' cases such as US, Canada, EU were reviewed thoroughly. Also, an appropriate method was suggested to apply domestically for a new or an enlarged facility permit within the regulations of the metropolitan special law. The method consists of first, calculating the possible permit quantity from the difference between an estimated annual emission cap and the annual emission provided by the implementation plan in each region. Second, permitting a new or an enlarged facility construction within the difference of the emission between the regional emission cap and the implementation plan in 2014. Third, distributing emissions allowable to each performance year based on the regional emission cap and the implementation plan in 2014. Fourth, making use of the emission difference between the implementation plan and the performance result in each year. Considering the general domestic conditions, the convenience of the permit authority and permitted companies, the most reasonable method was to use the fourth. To enforce the suggested permit method in a more flexible way, parts of the related regulations need to be revised and continuous research and analysis on the results from the implemented system and on foreign cases is necessary to develop this method a suitable system for domestic conditions and to settle the air pollutant emission cap system.

철강 산업의 산업공정부문 CO2 실측 배출계수 산정에 관한 연구 (An Estimation of Plant Specific Emission Factors for CO2 in Iron and Steel Industry)

  • 엄윤성;홍지형;김정수;김대곤;이수빈;송형도;이성호
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.50-63
    • /
    • 2007
  • The development of domestic plant specific emission factors is very important to estimate reliable national emissions management. This study, for the reason, was carried out to obtain advances emission factor for Carbon Dioxide ($CO_2$) by source-specific emission tests from the iron and steel industry sector which is well known as one of the major sources of greenhouse gases ($CO_2$). Emission factors estimated in this study were compared with those of IPCC for evaluation and they were found to be of similar level in the case of $CO_2$. There was no good information available on $CO_2$ plant specific emission factors from the iron and steel industry in Korea so far. The major emission sources of $CO_2$ examined from the iron and steel manufacturing precesses were a hot blast stove, coke oven, sintering furnace, electric arc furnace, heating furnace, and so on. In this study, the concentration of $CO_2$ from the hot blast stove process was the highest among all processes. The $CO_2$ emission factors for a ton of Steel and Iron products (using B-C oil) were estimated to be 0.315 $CO_2$ tonne (by Tier 3 method) and 4.89 $CO_2$ tonne. In addition, emission factor of $CO_2$ for heating furnace process was the highest among all process. Emission factors estimated in this study were compared with those of IPCC for evaluation and they were found to be of similar level in the case of $CO_2$.

SMOKE 모델의 입력 모듈 변경에 따른 영향 분석 (Assessment of Changed Input Modules with SMOKE Model)

  • 김지영;김정수;홍지형;정동일;반수진;이용미
    • 한국대기환경학회지
    • /
    • 제24권3호
    • /
    • pp.284-299
    • /
    • 2008
  • Emission input modules was developed to produce emission input data and change some profiles for Sparse Matrix Operator Kernel Emissions (SMOKE) using Clean Air Policy Support System (CAPSS)'s activities and previous studies. Specially, this study was focused to improve chemical speciation and temporal allocation profiles of SMOKE. At first, SCC cord mapping was done. 579 SCC cords of CAPSS were matched with EPA's one. Temporal allocation profiles were changed using CAPSS monthly activities. And Chemical speciation profiles were substituted using Kang et al. (2000) and Lee et al. (2005) studies and Kim et al. (2005) study. Simulation in Seoul Metropolitan Area (Seoul, Incheon, Gyeonggi) using MM5, SMOKE and CMAQ modeling system was done for effect analysis of changed input modules of SMOKE. Emission model results adjusted with new input modules were slightly changed as compared to using EPA's default modules. SMOKE outputs shows that aldehyde emissions were decreased 4.78% after changing chemical profiles, increased 0.85% after implementing new temporal profiles. Toluene emissions were decreased 18.56% by changing chemical speciation profiles, increased 0.67% by replacing temporal profiles as well. Simulated results of air quality were also slightly elevated by using new input modules. Continuous accumulation of domestic data and studies to develop input system for air quality modeling would produce more improved results of air quality prediction.