• 제목/요약/키워드: Air Vent Hole

검색결과 19건 처리시간 0.028초

박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사 (A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation)

  • 여경환;유인호;이한철;정재완;최경이
    • 농업과학연구
    • /
    • 제40권4호
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

초음속 유동 내 벤트 혼합기의 형상적 특성에 따른 성능 연구 (A Performance Study of Vent Mixer with Geometric Characteristics in Supersonic Flow)

  • 김채형;정인석
    • 한국항공우주학회지
    • /
    • 제37권1호
    • /
    • pp.69-75
    • /
    • 2009
  • 본 논문은 새로운 개념의 초음속 혼합기인 벤트 혼합기의 형상적 특성에 따른 공력 특성을 연구하였다. 홀의 크기는 2 mm이며 혼합기 벽면에서 2 mm 떨어진 곳에 위치한 모델(case 1)과 혼합기 벽면 뒤쪽에 위치한 모델(case 2)의 경우 같은 전압력 회복율을 보였으며, 홀의 크기를 반으로 줄인 1 mm(case 3) 모델은 cases 1, 2에 비해 낮은 전압력 회복율을 보였다. 재순환 영역의 크기는 cases 1-3은 같지만 전단층 두께는 cases 1, 2가 case 3 보다 두꺼웠다. 재순환 영역 내 압력 손실의 경우 cases 1, 2은 case 3에 비해 낮은 압력 손실과 높은 속도 구배를 보였으며, 이는 재순환 영역 내 공기와 연료의 혼합을 증대시키는 요인이다. 재순환 영역 내로 유입 되는 유동에 의해 형성되는 박리 버블은 연소기의 전압력 회복율과 재순환 영역 내 압력 분포와 순환 유동에 영향을 미친다. 따라서 박리 버블 형성에 영향을 주는 유입 공기 유량이 벤트 혼합기 성능에 주요한 영향을 미치는 것을 알 수 있다.

디스크 브레이크의 마찰열 접촉거동에 관한 트라이볼로지적 연구 - 벤트홀의 방열효과를 중심으로 - (Tribological Analysis on the Contact Behaviors of Disk Brakes Due to Frictional Heatings -Cooling Effects By Vent Holes-)

  • 김청균;황준태
    • Tribology and Lubricants
    • /
    • 제15권2호
    • /
    • pp.199-205
    • /
    • 1999
  • Using a coupled thermal-mechanical analysis, the thermal distortion of the ventilated disk brakes has been investigated based on the air cooling effects during 15 braking operations. The FEM results show that the bendings and distortions of the disk toward the left side are decreased, but the sinusoidal distortion of the disk rubbing surface along the arc length of the vent hole is highly increased by increasing the convective air cooling effects, which is heavily related to the squeal, wear and micro-thermal crackings at the rubbing surfaces due to uneven dissipation rates of friction heatings.

벤틸레이티드 디스크 브레이크에서 공냉효과가 열변형 거동에 미치는 영향에 관한 수치적 연구 (Numerical Study on the Thermal Distortions of Ventilated Disk Brakes Due to Air Cooling Effects)

  • 조승현;이일권;김청균
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.332-338
    • /
    • 1999
  • A coupled thermal-mechanical analysis has been presented for the thermal distortions of the ventilated disk brakes during IS braking operations. The FEM results show that the bendings and distortions of the disk toward the left side are decreased, but the sinusoidal distortion of the disk rubbing surface along the arc length of the vent hole is highly increased by increasing the convective air cooling effects, which is heavily related to the squeal, wear and micro-thermal crackings at the rubbing surfaces due to uneven dissipation rates of friction heatings.

  • PDF

자동차용 밸브 하우징의 2 캐비티 다이캐스팅 성형해석에 관한 연구 (A Study on the Forming Analysis of the 2 Cavity Die Casting for Automobile Valve Housing)

  • 이종형;이창헌;이상영;하홍배
    • 한국기계가공학회지
    • /
    • 제5권2호
    • /
    • pp.27-35
    • /
    • 2006
  • Al used in automobiles is mostly material, and according to the innovation of technique is in rapid development. Al die casting is an important field as today's trend of lightweight on automobiles. Valve housing in steering system improves driver's controling. The valve housing which is widely reliable to the most automobiles are developed this moment in our automobile industry. Therefore, they are produced by casting method which cost three times or even more expensive in production. If valve housing which is a part of steering system is produced by gravity casting, the space for manufacturing equipment will be increased, and more time and workers would be brought into service. For such reason, die casting would replace gravity casting in order to minimize cost of time, manpower, and working space. This study is the forming analysis of the 2 cavity die casting for automobile valve housing.

  • PDF

어린이 상해에 영향을 주는 조수석 에어백 설계 인자에 대한 연구 (A Study on the Passenger Airbag Design Parameters Influencing Child Injury)

  • 최원정;김권희;고훈건;김동석;손창규
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.176-181
    • /
    • 2009
  • The passenger airbag(PAB) designed for standard sized adults may induce unexpected results to children in out-of-position(OOP) postures. In this work, using MADYMO software, simulations of the OOP injury of children have been performed with respect to PAB design parameters and child dummy positions. The attention is focused on some details with respect to the injury of 3 and 6 year old children in two OOP postures. Among the various design parameters of the passenger airbag systems, four parameters are selected for the sensitivity analysis of the injury with the Taguchi method: bag folding pattern, vent hole size, position of the cover tear seam and the type of door tear seam. An optimal combination of the parameters is suggested.

無燃炭 燃燒에 關한 硏究 (第 1 報). 一酸化炭素 燃燒反應 및 燃燒裝置 (Studies on the Combustion of Anthracite (I). Combustion of Carbon Monoxide and the Furface)

  • 신병식;신세건
    • 대한화학회지
    • /
    • 제19권3호
    • /
    • pp.186-192
    • /
    • 1975
  • 燃炭을 燃燒시킬 때 흙통중에서 一定量의 煉炭을 一定時間 燃燒를 持續시키기 위하여 空氣의 供給을 制限하게 되므로 많은 量의 一酸化炭素가 發生한다. 그러므로 一酸化炭素의 發生을 抑制하는 基本實驗으로 窒素, 酸素 및 一酸化炭素의 混合가스 및 炭素의 存在下에서 一酸化炭素의 燃燒率을 測定한 結果 一酸化炭素 燃燒溫度는 $700^{\circ}C$以上이고 空氣의 供給이 增加 할수록 一酸化炭素의 燃燒率이 改善됨을 알았다. 이러한 事實에서 燃燒時間의 延長과 一酸化炭素의 發生 抑制는 서로 相反되므로 두 가지 條件을 滿足시키는, 보다 效果的 燃燒裝置를 考案하였다. 즉 內徑이 다른 二重鐵筒으로 暖爐를 만들어 若干의 二次空氣가 에어자켓 下部에서 들어가 上部의 작은 구멍에서 나오게끔 하면 燃燒中인 煉炭과 熱交換되어 燃燒雰圍氣의 溫度는 低下된다. 따라서 燃燒時間은 길어지면 또 二重鐵筒을 通하여 上昇하는 豫熱空氣는 一酸化炭素의 再演燒를 促進시키게 되므로 一酸化炭素의 發生量은 흙통을 使用하였을때 보다도 1/20 程度로 減少된다.

  • PDF

스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel)

  • 박원희;김창용;조영민
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권9호
    • /
    • pp.721-736
    • /
    • 2019
  • 본 논문에서는 대심도에 위치한 지하역사(지하 6층) 및 터널에서 화재가 발생했을 경우 제연설비 작동에 따른 연기의 거동을 측정하였다. 열풍기를 이용하여 열부력 효과를 구현한 연기발생장치를 이용하여 화재연기를 생성하였다. 화재발생 위치는 승강장 위 및 스크린도어 외부에 위치한 터널부의 승강장 위의 2가지 위치를 선정하였다. 승강장 화재발생시 승강장에 설치된 환기구를 통하여 연기가 배출되도록 하는 제연모드가 일반적인데 본 연구에서는 승강장 양단에 위치한 터널부의 환기구를 통한 배기도 같이 동작되도록 설정하여 실험을 수행하였다. 다양한 위치에서 연기농도 및 풍향풍속을 측정하였고 화면을 취득하여 연기의 이동 및 제연을 분석하였다. 승강장 내부에서 화재가 발생하였을 경우와 선로부에서 화재가 발생하였을 경우 승강장의 송풍기의 제연모드 동작과 터널의 송풍기의 배연 동작으로 인하여 연기배출이 원활하였고 화재 발생 인근 구역으로의 연기전파가 억제되었다. 본 연구에서 제시한 승강장 및 승강장 양단부의 터널에 적용되는 송풍기를 같이 운전하는 제연모드를 통하여 승강장 화재 및 화재열차 정차시 화재 연기로부터 승객들에게 보다 안전한 대피환경을 제공할 수 있을 것이다.