• Title/Summary/Keyword: Air Tank

Search Result 609, Processing Time 0.023 seconds

A Study on the Separation of Activated Sludge by Dissolved Air Flotation (가압부상법(加壓浮上法)에 의한 활성(活性)슬러지 혼합액(混合液)의 고액분리(固液分離)에 관한 연구(研究))

  • Yang, Sang Hyun;Ra, Deog Gwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.21-29
    • /
    • 1985
  • An effective technique of sludge separation is required for concentrated activated sludge process. The dissolved-air flotation (DAF) has been shown to be efficient process for sludge separation. The factors affecting DAF process for activated sludge separation are type and concentration of sludge, air/solid ratio, ratio of pressurized water flow, pressure, sludge detention time, temperature, sludge and hydraulic loading rate, recycle flow rate of sludge and type and quantity of chemical aid. In order to study the optimal operation condition for sludge separation, the influence factors such as type and concentration of sludge, ratio of pressurized water flow and pressure are investigated by the batch and continuous reactor experiments of DAF and sedimentation test. By the experimental investigation, the results are as follows; 1. For the bulking and concentrated sludge, DAF is more effective than sedimentation for the sludge separation. 2. In DAF, the critical ratio of pressurized water flow exist. The critical value varies with the pressure in the tank. That is, according to the pressure changes from 3 to $5kg/cm^2$, the critical value varies from 0.25 to 0.67 accordingly. 3. Pressure affects the ratio of pressurized water flow, but it does not show any influence upon the DAF efficiency directly. 4. Continuous experimental results was not better than those of batch.

  • PDF

Design of Portable Welded-Nitrogen Vessel (11 kg, 10 L and 50 bar) for Shipbuilding (선박용 휴대형 질소용기(11 kg, 10 L 및 50 bar)의 두께 및 외형 설계)

  • Seong, Hansaem;Kim, Jaeyeol;Eom, Taejin;Kawk, Hyo Seo;Lee, Kwang O;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.263-270
    • /
    • 2017
  • The shipbuilding industry uses large stationary tanks to store low-pressure air, which is used to open and close large shut-off valves. However, when supplying air from the tank to a distant valve, there are problems related to the need for supplementary pipes and the pressure drop during transportation. In this study, a portable welded vessel for storing high-pressure nitrogen (11 kg, 10 L, and 50 bar) was designed to prevent air leakage and improve the convenience of workers. This pressure vessel was elliptical to reduce the number of welded parts, which are structurally weak. The thickness and ratio of the major and minor axes of the pressure vessel were calculated to verify its structure stability at the working pressure (50 bar), and that the proposed weight and capacity were satisfactory. The residual stress caused by the welding process was calculated by performing a transient thermal-structural coupled field analysis using the ANSYS parametric design language (APDL), and the fatigue life of the vessel was verified based on the Goodman criterion.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Design and Operation Guideline (바이오가스 이용 기술지침 마련을 위한 연구(III) - 기술지침(안) 중심으로)

  • Moon, HeeSung;Bae, Jisu;Pack, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.95-103
    • /
    • 2018
  • As a guideline for desulfurization and dehumidification pretreatment facility for optimizing utilization of biogas, the $H_2S$ concentration is set at 150 % which can be treated with iron salts, dehumidification is the optimum value for generator operation, and the relative humidity applied at the utilization of biogas in EU is set at 60 %. We have set up the generator facility guidelines to optimize utilization of biogas. The appropriate amount of biogas should be at least 90 % of the total gas generation, and the capacity of generator facility should be set at 20~30 %. In order to equalize the pressure of the incoming gas the generator, a gas equalization tank should be installed and the generator room average temperature should be kept at $45^{\circ}C$ or less. Since the gas is not produced at a certain methane concentration in the digester, the efficiency is lowered. Therefore, it is required to install an air fuel ratio control system according to the change in methane concentration. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure), investigate the facilities problem and propose design, operation guidelines such as pre-treatment facilities and generators.

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

The proposal for pesticide exposure estimation of Korean orchard farmer (과수 농작업자 농약노출량 산정법 제안)

  • Hong, Soon-Sung;Lee, Je-Bong;Park, Yeon-Ki;Shin, Jin-Sup;Im, Geon-Jae;Ryu, Gab-Hee
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.4
    • /
    • pp.281-288
    • /
    • 2007
  • This research was carried out to propose the Korean method for estimating the agricultural occupational pesticide exposure level in orchard. The UK-POEM (UK-Predictive Operator Exposure Model) was proposed as a bench-marking model and analysed its performance properties. To extrapolate the Korean agricultural conditions, application equipment, application method, work rate per day, application volume and spraying time of pesticide was surveyed for Korean 204 orchard farmhouse. This survey indicate that the major application equipments are speed sprayer(64.9%) and motor sprayer(33.9%). When they spayed the pesticide with a speed sprayer, they worked for more than 4 hours on area of 4 ha per day. In case of using motor sprayer, they worked for more than 4 hours on area of 1 ha. Based on the above survey result, Korean method for estimating the pesticide exposure level of agricultural worker was proposed finally.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Development of Robot Platform for Autonomous Underwater Intervention (수중 자율작업용 로봇 플랫폼 개발)

  • Yeu, Taekyeong;Choi, Hyun Taek;Lee, Yoongeon;Chae, Junbo;Lee, Yeongjun;Kim, Seong Soon;Park, Sanghyun;Lee, Tae Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.168-177
    • /
    • 2019
  • KRISO (Korea Research Institute of Ship & Ocean Engineering) started a project to develop the core algorithms for autonomous intervention using an underwater robot in 2017. This paper introduces the development of the robot platform for the core algorithms, which is an ROV (Remotely Operated Vehicle) type with one 7-function manipulator. Before the detailed design of the robot platform, the 7E-MINI arm of the ECA Group was selected as the manipulator. It is an electrical type, with a weight of 51 kg in air (30 kg in water) and a full reach of 1.4 m. To design a platform with a small size and light weight to fit in a water tank, the medium-size manipulator was placed on the center of platform, and the structural analysis of the body frame was conducted by ABAQUS. The robot had an IMU (Inertial Measurement Unit), a DVL (Doppler Velocity Log), and a depth sensor for measuring the underwater position and attitude. To control the robot motion, eight thrusters were installed, four for vertical and the rest for horizontal motion. The operation system was composed of an on-board control station and operation S/W. The former included devices such as a 300 VDC power supplier, Fiber-Optic (F/O) to Ethernet communication converter, and main control PC. The latter was developed using an ROS (Robot Operation System) based on Linux. The basic performance of the manufactured robot platform was verified through a water tank test, where the robot was manually operated using a joystick, and the robot motion and attitude variation that resulted from the manipulator movement were closely observed.

Evaluation of Formaldehyde Exposure for Formalin Spraying Work of Fish Farm Workers (양식업 종사자 포르말린 살포 작업에 대한 포름알데히드 노출평가)

  • Eun Young Kim;Sungwon Choi;Sungsook Lee;Hyerim Son;Jin Ee Baek;Jae Hoon Shin;Deaho Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.403-411
    • /
    • 2023
  • Objectives: Formalin is used as an anthelmintic in farms where flounder are raised. In this study, we aim to identify formaldehyde exposure levels for aquaculture industry workers and provide basic data for managing formaldehyde exposure. Methods: Exposure levels of formaldehyde in the air, including formalin spraying operations, were assessed separately for personal and area samples. In addition, considering the formalin administration method, dermal exposure to the hands was estimated when administering the chemical, and dermal exposure to the legs during water tank work was estimated by collecting water in the water tank and evaluating the amount of formaldehyde remaining. Finally, the respiratory exposure level and the estimated dermal exposure level were added to derive the total exposure level and compared with the maximum allowable human dose. Results: As a result of the airborne evaluation, the formaldehyde concentration of the worker (1 person) who performed the formalin spraying and flounder sorting was 33.61 ppb, and the arithmetic mean of formaldehyde concentrations of the workers (3 people) who only performed the flounder sorting was 3.28 ppb (range: 2.25-4.89 ppb). In the case of dermal exposure, when spraying formalin once, the amount was estimated to be 0.33-2.62 mg when wearing protective gear and 3.27-26.12 mg when not wearing it. Conclusions: There was a difference in the formaldehyde exposure level of workers depending on their operation of handling formalin and whether or not protective gear was worn. In particular, because the level of formaldehyde exposure due to dermal exposure can be significant, there is a need to improve formalin administration methods in a way that avoids skin contact as much as possible.

A Study on the Production of Artificial Seed and Intermediate culture for Attached Spats of the Chinese Stock of a Scallop, Patinopecten yessoensis (중국산 참가리비, Patinopecten yessoensis의 인공종묘 생산 및 부착치패 중간양성에 관한 연구)

  • Oh, Bong-Se;Lee, Jeong-Yong;Park, Se-Ku;Lee, Chu;Jo, Q-Tae
    • The Korean Journal of Malacology
    • /
    • v.24 no.2
    • /
    • pp.153-159
    • /
    • 2008
  • We investigated artificial mass seed production of a Chinese scallop, Patinopecten yessoensis, in 2004. The GSI(gonad somatic index) of the Chinese scallop, P yessoensis was 17.2 on mid-February, 20.2 on mid-March, while that of Korean scallop, P yessoensis was 6.9 on mid-February, 10.8 on mid-March. Matured 120 females and 350 males were selected for artificial mass production. They were exposed in air for 1 hr at over $20^{\circ}C$, and placed into a spawning tank(20 ton) containing sea water treated with UV radiation at $12^{\circ}C$. We gained a total of 228,000 thousand scallop embryos between March 10th and 15th, and reared larvae at the indoor tank during 25 days. When the mean shell length of larvae reached 250 ${\mu}m$ and they have eye-spots, the number of pre-settling larvae was 47,500 thousand. We gained 1,850 thousand attached scallop spats from two kinds of collectors. Attached spats were reared in indoor tank for different periods from 5 days to 60 days. They were divided into 5 groups according to the length of reared days. Each group of attached spats was moved to intermediate rearing sites at Yangyang fishing port in Gangreung-city for acclimation to ocean environments. The highest survival rate of attached spats was 13.0% shown at the group reared for 12 days, but the significant difference in their growth was not found between the groups. The shell length of artificial attached spats increased from 0.9 ${\mu}m$ on July 10th to 24.7 ${\mu}m$ on December 16th with the survival rate of 85.0% while that of natural attached spats increased from 0.6 ${\mu}m$ on July 10th to 23.9 ${\mu}m$ on December 16th with the survival rate of 85.7%.

  • PDF

The Stydy on Application to Cosmetics of Phellinus Iimteus

  • Young-Ho Cho;Chu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.101-107
    • /
    • 1997
  • Phellinus linteus was artificially cultivated in kangwon province in Korea. The air-dried phellinus linteus was frozen in liquid nitrogen tank and powdered in jar. 10g of the powder was extracted with each 200g of ethanol, methanol, distilled water and 1,3-butylene glycol/distilled water 4 hours under refluxing and then the liquidextract was concentrated under reduced pressure. As a result of analysis by high performance liquid chromatography and thin layer chromarography, many kinds of sugar and flavonoids were detected. Also we knew that phellinus linteus' extract had a strong UV-ray absorption. In the efficacy test for applying to cosmetics, free radical scavenging effect was confirmed. As a result, 2% of sample was the most potent inhibitory effect and the free radical savenging activity, was 0.31%. This is more effective than any other meterial. In the test of antioxidative activity against lipid autoxidation, phellinus linteus' extract had a good effect by 46% while vitamine E was 42.3%. The immunological activity of phellinus linteus was showed through the activation of macrophage cell. Actually, phellinus linteus activated macrophage function of 1.1-1.8 times including nitrite production compared to control. The whitening effect of phellinus linteus was showed through the inhibition of tyrosinase activity, melanin biosynthesis of S. bikiniensis and B-16 melanoma cells. Phellinus linteus' extract was showed strong mushroom tyrosinase inhibitory activity with IC50 value of 0.5% and inhibited melanin biosynthesis with 28mm inhibition zone at 0.005%/paper disc in S. bikinniensis, a bacterium used as an indicator organism in this work. Also it inhibited melanin biosynthesis in B-16 melanoma cells with a minimum inhibitory concentration of 0.134%.

  • PDF