• Title/Summary/Keyword: Air Supplying System

Search Result 101, Processing Time 0.03 seconds

A Study on Forced Aspirating Air Supplying Module for Micro Fuel Cell (마이크로 연료전지용 강제 호흡형 공기 공급 모듈에 관한 연구)

  • Hwang, Jun-Young;Yun, Hyo-Jin;Lee, Sang-Ho;Kang, Heui-Seok;Kang, Kyun-Tae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.49-52
    • /
    • 2008
  • The present study conducts a series of experiments to develop a novel air supplying module for a micro fuel cell using piezoelectric linear actuator. An intermittently and operating air breathing module with reciprocating motion of the linear actuator has been suggested in the present study. A test bench for a micro fuel cell system has been constructed to estimate performance of the active fuel cell system using the air supplying module. With the stroke and operating duty as main control parameters, the optimal operating method of the air supplying module has been discussed.

  • PDF

Air Supplying System for DMFC using Piezo Actuators (압전 액추에이터를 이용한 DMFC의 공기 공급 시스템)

  • Hong, Chol-Ho;Kim, Dong-Jin;Yun, Hyo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1585-1591
    • /
    • 2010
  • DMFC uses oxygen by reactants. Therefore, cathode electrode must contact with outside air. However, when used in mobile devices, the user's body by blocking the air intake on the oxygen supply DMFC con not. DMFC to supply air to the cooling fan is used. However, by using cooling fan, air inlet to the pressure loss and changes will occurs, the output will be worse. In this paper, we designed air supplying system using piezo actuators. We DMFC evaluation system was implemented, verified the performance of air supplying system. And the operation was connected to an MP3 player.

Effect of Swirl Angle on the Atomization Characteristics in Twin-Fluid Nozzle with Dual Air Supplying (이중공기공급 2-유체 노즐의 선회각 변화에 따른 미립화 특성)

  • Woo, J.M.;Kim, E.S.;Kim, D.J.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.126-133
    • /
    • 2008
  • The atomization characteristics of the dual air supplying two-fluid nozzle were investigated experimentally using PIV and PDA systems. The twin-fluid nozzle is composed of three main parts: the feeding injector to supply fluid that is controlled by a PWM (pulse-width modulation) mode, the adaptor as a device with the ports for supplying the carrier and assist air, and the main nozzle to produce sprays. The main nozzle has the swirler with four equally spaced tangential slots, which gives the injecting fluid an angular momentum. The swirl angle in the swirler varied with $0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$. The ratios of carrier air to assist air and ALR (total air to liquid) were 0.55 and 1.23, respectively. The macroscopic behavior of the spray was investigated using PIV system, and the AMD and SMD distributions of the sprays were measured using PDA system. As a result, the SMD distribution increases along the radial distance, and it decreases with the increase of swirl angle in swirler.

  • PDF

MODELING AND OPTIMIZATION OF THE AIR- AND GAS-SUPPLYING NETWORK OF A CHEMICAL PLANT

  • Han, In-Su;Han, Chong-Hun;Chung, Chang-Bock
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.377-382
    • /
    • 2004
  • This paper presents a novel optimization method for the air- and gas-supplying network comprised of several air compression systems and air and gas streams in an industrial chemical plant. The optimization is based on the hybrid model developed by Han and $Han^1$ for predicting the power consumption of a compression system. A constrained optimization problem was formulated to minimize the total electric power consumption of all the compression systems in the air- and gas-supplying network under various operating constraints and was solved using a successive quadratic optimization algorithm. The optimization approach was applied to an industrial terephthalic acid manufacturing plant to achieve about 10% reduction in the total electric power consumption under varying ambient conditions.

  • PDF

A Study on the system Applied Air-Vent to Complex Lay Poly-Urethane Waterproofing Material and Air-Permeability Buffer Sheet of Disconnection Type (Web기반을 활용한 자재 조달 시스템 개선방안)

  • Lee, Im-Bae;Kim, Hong-Hyun;Yoon, Su-Won;Min, Kyung-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.141-145
    • /
    • 2008
  • Because of world financial crisis, The Korea domestic construction industry has been damaged hugely on material supplying work. A current domestic material supply system can't react properly on a great rise of foreign exchange rate and raw material price, so the system has a problem which is not properly supplying material. To solve this problem, a more innovative material supply work system is seriously needed than ever. So this study wants to improve material supply system for supplying material right time, right place through applying a web-based system. Applying this, overall process of material-supply-work can be done on a web-based system for immediately understanding change of ordering and warehousing by material-supply-schedule to a domestic construction field.

  • PDF

Effect of Swirl Angle on the Atomization Characteristics in Two-Fluid Nozzle with Dual Air Supplying System (이중공기공급 이유체노즐의 선회각 변화에 따른 분무특성)

  • Kim, E.S.;Kang, S.M.;Choi, Y.J.;Kim, D.J.;Lee, J.K.;Rho, B.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.54-60
    • /
    • 2008
  • The atomization characteristics of the dual air supplying twin-fluid nozzle were investigated experimentally using PIV and PDA systems. The two-fluid nozzle is composed of three main parts: the feeding injector to supply fluid that is controlled by a PWM (pulse-width modulation) mode, the adaptor as a device with the ports for supplying the carrier and assist air and the main nozzle to produce the spray. The main nozzle has the swirl tip with four equally spaced tangential slots, which give the injecting fluid an angular momentum. The angle of the swirl tip varied with 0$^{\circ}$ 30$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$, and the ratios of carrier air to assist air and ALR(total air to liquid) were 0.55 and 1.23, respectively. The macroscopic behavior of the spray was investigated using PIV system, and the mean velocity, turbulent intensity and SMD distributions of the sprays were measured using PDA system. As the results, the mean axial velocity at the spray centerline decrease with the increase of the swirl angle. The turbulent intensities of the axial and radial velocity were increased with the increase of the swirl angle. The mean SMD (Sauter mean diameter) of the radial direction along the axial distance shows the lowest value at the swirl angle of 60$^{\circ}$.

  • PDF

The Analysis Study on Supplying Heat by Various Control Methods in District Heating System (지역난방 시스템에서 제어방법에 따른 공급열량의 해석적 연구)

  • Kim, Seong-Su;Jung, Sang-Hum;Moon, Youn-Jin;Cho, Sung-Hwan;Ryu, Jae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1008-1013
    • /
    • 2009
  • The theoretical simulation to predict the variation of supplying heat according to control methods of DHS(District Heating System) have been done by TRNSYS(A Transient System Simulation Program) 16. The physical system for DHS consists of primary and secondary supplying heating loop which is divided by based on heat exchanger for heating demand of building. The simulation results showed that control of secondary supplying heat had influenced more than primary supplying heat control to total energy consumption of DHS. And the outside temperature reset control of primary supplying heating loop could be reduced until about 4% overheating of each zone.

  • PDF

A Study on Numerical Simulation for the Work Environment Improvement of Highway Tollgate Booth (고속도로 요금소 부스 근무환경 개선을 위한 기류해석 연구)

  • 김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.129-140
    • /
    • 2000
  • Simulation study has been carried out to analyze the air flow supplying from the heat pump system inside the tollgate booth by using the Phoenix computer simulation program. Through this simulation analysis we can find the problem of present tollgate booth in terms of air flow and recommend an improved model also simulate this model. Final results as follows; It was turned out that the fresh air conditioning is not provided to the worker effectively due to the improper location of inlet and outlet in the present tollgate booth in addition to that the air curtain system applied in the booth lowered air circulation from outside. The improved model was suggested first to increase the air curtain effect by downsizing the window and by installation of the air curtain suction line to reduce the induced outdoor air second to supply the fresh air to the worker directly by relocation of the inlet and outlet of supplying air. With these improved modifications better results have been reached in terms of air flow inside the booth. Next through the air flow simulation of outside booth the contaminated outdoor air has been easuily infiltrating into the booth through the window because of its rectangle shape. Stream like shape of booth has been proposed through the computer simulation as an alternative shape of tollgate booth for a new design.

  • PDF

Estimation of the thermal performance on the double slab floor with supplying air (급기가 되는 이중바닥 구조체의 열 성능 평가)

  • Cha, Kwang-Seok;Park, Myung-Sig;Lee, Dae-Woo;Nam, Woo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.