• Title/Summary/Keyword: Air Supply System

Search Result 881, Processing Time 0.035 seconds

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

Air Supplying System for DMFC using Piezo Actuators (압전 액추에이터를 이용한 DMFC의 공기 공급 시스템)

  • Hong, Chol-Ho;Kim, Dong-Jin;Yun, Hyo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1585-1591
    • /
    • 2010
  • DMFC uses oxygen by reactants. Therefore, cathode electrode must contact with outside air. However, when used in mobile devices, the user's body by blocking the air intake on the oxygen supply DMFC con not. DMFC to supply air to the cooling fan is used. However, by using cooling fan, air inlet to the pressure loss and changes will occurs, the output will be worse. In this paper, we designed air supplying system using piezo actuators. We DMFC evaluation system was implemented, verified the performance of air supplying system. And the operation was connected to an MP3 player.

System Response of Automotive PEMFC with Dynamic Modeling under Load Change (차량용 PEMFC 동적 모델을 이용한 시스템 부하 응답 특성)

  • Han, Jaeyoung;Kim, Sungsoo;Yu, Sangseok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.43-50
    • /
    • 2013
  • The stringent emission regulation and future shortage of fossil fuel motivate the research of alternative powertrain. In this study, a system of proton exchange membrane fuel cell has been modeled to analyze the performance of the fuel cell system for automotive application. The model is composed of the fuel cell stack, air compressor, humidifier, and intercooler, and hydrogen supply which are implemented by using the Matlab/Simulink(R). Fuel cell stack model is empirical model but the water transport model is included so that the system performance can be predicted over various humidity conditions. On the other hand, the model of air compressor is composed of motor, static air compressor, and some manifolds so that the motor dynamics and manifold dynamics can be investigated. Since the model is concentrated on the strategic operation of compressor to reduce the power consumption, other balance of components (BOP) are modeled to be static components. Since the air compressor model is empirical model which is based on curve fitting of experiments, the stack model is validated with the commercial software and the experiments. The dynamics of air compressor is investigated over unit change of system load. The results shows that the power consumption of air compressor is about 12% to 25% of stack gross power and dynamic response should be reduced to optimize the system operation.

Performance analysis of oil free air compressor for automotive electronic air suspension system (차량용 공기현가장치의 무급유 공기압축기 성능해석)

  • Shim, Jae-Hwi;Kim, Ho-Young;Lee, Yong-Ho;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.572-577
    • /
    • 2006
  • Numerical simulation has been made on the performance of an oil free air compressor for automotive electronic air suspension system. Calculation results on the flow rate at various air supply pressures were reasonably well compared to the experimental data. With the aid of the computer simulation program, parametric study on the compressor design parameters has also been carried out for the compressor performance improvement: Increase in the discharge port diameter or discharge valve stiffness was found to be effective to increase the flow rate per unit compressor input for the present compressor model.

  • PDF

Study on the Air Foil Bearings of the Turbo-Expander for Fuel Cell System (연료 전지용 터보 익스펜더의 공기 포일 베어링에 대한 연구)

  • Lee Yong-Bok;Park Dong-Jin;Kim Chang-Ho
    • Tribology and Lubricants
    • /
    • v.21 no.3
    • /
    • pp.114-121
    • /
    • 2005
  • As fuel cell system is environmental friendly generator, its performance depends on its air supply system. Because, fuel cell stack generates electrical energy by electron and the electron is generated by reacting between air and hydrogen. So, more and more compressed air is supplied, more and more the energy can be obtained. In this study, turbo-expander supported by air foil bearing is introduced as the air supply system used by fuel cell systems. The turbo-expander is a turbo machine which operates at high speed, so air foil bearings suit its purpose for the bearing elements. Analysis for confirming the stability and endurance is conducted. Based on FDM and Newton-Raphson method, characteristics of air foil bearing, dynamic coefficients, pressure field and load capacity, are obtained. Using the characteristics of air foil bearing, the rotordynamic analysis is performed by finite element method. The analysis (stability analysis and critical speed map) shows that turbo-expander is stability at running speed. After the analysis, the test process and results are presented. The goals of test are running up to 90,000 RPM, flow rate of 150 $m^3/h$ and pressure ratio of 1.15. The test results show that the aerodynamic performance and stability of turbo-expander are satisfied to the primary goals.

Selection of Diffuser for Lower Temperature Air Distribution System (저온공조용 취출구의 선정)

  • Park, Sung-Kyu;Yoo, Ho-Joon;Choi, Myeong-Shin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.484-492
    • /
    • 2008
  • Air Discharge pattern and even temperature distribution is critical for a successful lower temperature air distribution system, which would supply lower temperature air than normal HAVC system. Selection of appropriate diffuser is the most critical element in completing lower temperature system.

  • PDF

Cooling Cycle for Energy Saving (에너지 절약용 냉방사이클)

  • Lee, Hung Joo;Kim, Yong Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System (기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.31-37
    • /
    • 2012
  • This paper describes to analyze the ventilation performance of a room air conditioner for indoor comfort control. An experimental apparatus consists of a test room, the room air conditioner, a tracer gas measurement system, a supply fan and a controller. Ventilation performance as a function of human occupancy is evaluated with supply ventilation air using a tracer gas technique of CO2 gas in the test room. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 and is found to increase with increasing supply ventilation rate. The CO2 gas concentration is decayed rapidly without human occupancy. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570 lpm comparing with a natural reduction after one hour. A modeling for ventilation performance of a room air conditioner in a test room is presented using experimental datum.

A PID Control of Electric Heater for PEM (개별공조시스템을 위한 전기히터의 PID 제어)

  • 장영준;박영칠;정광섭;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.59-65
    • /
    • 2001
  • The work presented here is an implementation of PID control to achieve a required supply air temperature in PEM(Personal environment module). In PEM, the air is heated to the required temperature while it flows through the supply duct, without any mixing chamber. This makes the control of air temperature in PEM difficult. Linear dynamic model of heat transfer in PEM is first obtained. Then P, PD and PID type control systems, to provide the rapid response without overshoot and saturation, are designed and implemented experimentally. Data obtained shows that the control system satisfied the design criteria and works properly in controlling the supply air temperature.

  • PDF