• Title/Summary/Keyword: Air Resistance

Search Result 1,593, Processing Time 0.03 seconds

A numerical study on the aerodynamic characteristics of a variable geometry throttle valve(VGTV) system controlling air-flow rate (유량 제어장치인 가변스로틀밸브의 기하학적 형상변화에 따른 공기역학 특성분석 연구)

  • Cho, Hyun-Sung;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.378-383
    • /
    • 2013
  • A butterfly throttle valve has been used to control the brake power of an SI engine by controlling the mass flow-rate of intake air in the induction system. However, the valve has a serious effect on the volumetric efficiency of the engine due to the pressure resistance in the induction system. In this study, a new intake air controlling valve named "Variable Geometry Throttle Valve(VGTV)" is proposed to minimize the pressure resistance in the intake system of an SI engine. The design concept of VGTV is on the application of a venturi nozzle in the air flow path. Instead of change of the butterfly valve angle in the airflow field, the throat width of the VGTV valve is varied with the operating condition of an SI engine. In this numerical study, CFD(computational fluid dynamics) simulation technique was incorporated to have an aerodynamics performance analysis of the two air flow controlling systems; butterfly valve and VGTV and compared the results to know which system has lower pressure resistance in the air intake system. From the result, it was found that VGTV has lower pressure resistance than the butterfly valve. Especially VGTV is effective on the low and medium load operating condition of an SI engine. The averaged pressure resistance of VGTV is about 49.0% lower than the value of the conventional butterfly throttle valve.

The Analysis of Heat Transfer through the Multi-layered Wall of the Insulating Package

  • Choi, Seung-Jin
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.12 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • Thermal insulation is used in a variety of applications to protect temperature sensitive products from thermal damage. Several factors affect the performance of insulation packages. Among these factors, the thermal resistance of the insulating wall is the most important factor to determine the performance of the insulating package. In many cases, insulating wall consists of multi-layered structure and the heat transfer through this structure is a very complex process. In this study, an one-dimensional mathematical model, which includes all of the heat transfer principles covering conduction, convection and radiation in multi-layered structure, were developed. Based on this model, several heat transfer phenomena occurred in the air space between the layer of the insulating wall were investigated. From the simulation results, it was observed that the heat transfer through the air space between the layer were dominated by conduction and radiation and the low emissivity of the surface of each solid layer of the wall can dramatically increase the thermal resistance of the wall. For practical use, an equation was derived for the calculation of the thermal resistance of a multi-layered wall.

  • PDF

Freezing and Thawing Resistance of Latex Modified Concrete with Latex Content (라텍스 혼입에 따른 LMC의 동결융해 저항특성평가)

  • 이주형;정원경;김동호;이봉학;원치문;이정호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.497-502
    • /
    • 2000
  • This study was performed to change the latex content for properties of freezing-thawing resistance. When styrene-butadiene latex is added to portland cement, aggregate and water, a concrete with the color, consistency and workability of ordinary conventional concrete results, but with 20% to 35% less water. When cured, the concrete consists of hydrated cement and aggregate interconnected by a film of latex particles. In general, increasing the amount of latex will produce concrete with increased tensile and flexural strength and lower modulus of elasticity. Air entrainment has been used in conventional concrete for the past 50 years to impart freeze-thaw resistance. Latex modified concrete does not need additional air entrainment for freeze-thaw resistance provided adequate cure occurs.

  • PDF

A Study of Dynamic Characteristic far Resistance Spot Welding Process Using Servo-gun System (서보건 이용 시 저항 점 용접의 동특성 분석에 관한 연구)

  • Baek Jung-Yeub;Lee Jong-Gu;Rhee Se-Hun
    • Journal of Welding and Joining
    • /
    • v.23 no.3
    • /
    • pp.40-46
    • /
    • 2005
  • Air gun has been one of the good tools to press two sheet metals. However, it is not easy to control the acting force precisely. A Servo-gun is a good tool to control the acting force on the workpiece comparing with the air gun. Servo-gun has a higher tensile shear strength and lower indentation depth as well as smaller spatter. Dynamic resistance was obtained according to the acting force and welding current. As the acting force was changed during welding, the welding quality was increased.

Optimization of Resistance Spot Welding Process Using Servo-gun System (서보건을 이용한 저항 점 용접 공정의 최적 용접 조건 설정에 관한 연구)

  • 백정엽;김태형;이종구;이세헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.679-682
    • /
    • 2002
  • Resistance spot welding using air gun has been used for joining the sheet metal in automotive manufacturing process. Although air gun has many advantages, it also has the limitation to control the pressure as a factor to improve weld quality. In this study, we apply servo gun using servo motor to resistance spot welding and find the relationship between welding pressure and welding quality. Trough the experiment to change welding pressure during the welding cycle, we can make it clear that the change of welding pressure is greatly influence on the welding quality. To get in a. using response surface methodology, drew out the optimal welding pressure profile for welding quality progresses. We made an optimal profile of welding pressure which improves welding quality using response surface methodology.

  • PDF

The Study about Cooling Effect of a Heated module in a Horizontal Channel with a Variation of Channel Height (수평채널 밑면에 부착된 단일 발열모듈에서 채널높이의 변화에 따른 냉각특성 연구)

  • 이진호;유갑종;장준영;김병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.348-355
    • /
    • 2001
  • The coupled conduction and convection heat transfer from a protruding heated module in a horizontal channel with a variation of channel height is experimentally investigated. The input power to the module is 3, 7W and thermal resistance of module support is 0.06 , 1.03 and 158K/W. the Reynolds number ranged from 350 to 4500 corresponding to the inlet velocity(0.4~1.3 m/s) and channel height(11~35 mm). The results were obtained that the decrease of thermal resistance of module support reduces the module temperature by redistributing the heat flux and the overall thermal resistance of the module. In the study the effect of channel height is very significant in the adiabatic condition, but negligible in the conjugate condition. Finally, correlations for Nusselt number and $Q_B$/Q with a variation of Reynolds number were developed respectively.

  • PDF

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

Analysis of energy consumption of office building by thermal resistance-capacitance method (열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석)

  • Lee, C.S.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

The Effect of MnO2 Content on the Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.4
    • /
    • pp.331-339
    • /
    • 2017
  • Porous alumina-based ceramics are of special interest due to their outstanding mechanical properties and their thermal and chemical stability. Nevertheless, the high electrical resistance of alumina-based ceramics, due to the generation of static electricity, leads to difficulty in applying a vacuum chuck in the semi-conductor process. Therefore, development of alumina-based ceramics for applications with vacuum chucks aims to have primary properties of low electrical resistance and high air permeability. In this study, we tailored the electrical resistance of porous alumina-based ceramics by adjusting the amount of $MnO_2$ (with $TiO_2$ fixed at an amount of 2 wt%) and by using coarse alumina powder for high air permeability. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimeter, capillary flow porosimetry, universal testing machine, X-ray diffraction and high-resistance meter.

A Study on Flow Characteristics of Branch Type Sparger in Drain Tank for Depressurization (감압용 배수탱크내의 분기형 증기분사기의 유동특성에 관한 연구)

  • 김광추;박만흥;박경석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.356-367
    • /
    • 2001
  • A numerical analysis on branch type sparger in drain tank for depressurization is performed to investigate the flow characteristics due to the change of design factor. As the result of this study, sparger\\`s flow resistance coefficient(K) is 3.53 at the present design condition when engineering margin for surface roughness is considered as 20%, and flow ratio into branch pipe ($Q_s/Q_i$) is 0.41. The correlation for calculating flow resistance coefficients as design factor is presented. Flow resistance coefficient is increased as section area ratio of branch pipe for main pipe and outlet nozzle diameter of main pipe decreasing, but the effects of branch angle and inlet flow rate of main pipe are small. As the change rate of ($Q_s/Q_i$)becomes larger, the change rate of flow resistance coefficient increases. The rate of pressure loss has the largest change as section area ratio changing. The condition of maximum flow resistance in sparger is when the outlet nozzle diameter ratio of main pipe ($D_e/D_i$) is 0.167, the section area ratio ($A_s/A_i$) is 0.1 and the branch angle ($\alpha$) is 55^{\circ}$.

  • PDF