• 제목/요약/키워드: Air Quality Control

검색결과 932건 처리시간 0.255초

배출계수법과 연속자동측정법에 의한 배출량 비교 연구 (A Study on the Comparison of Emission Factor Method and CEMS (Continuous Emission Monitoring System))

  • 장기원;이주형;정성운;강경희;홍지형
    • 한국대기환경학회지
    • /
    • 제25권5호
    • /
    • pp.410-419
    • /
    • 2009
  • Generally, air pollutant emission at workplace is estimated by two methods: indirect methods using emission factors and direct methods based on CEMS (Continuous Emission Monitoring System). CAPSS (Clean Air Policy Support System) is a representative indirect method and the national air pollutant database of Korea. However, characteristics of some workplaces may create a gap between CAPSS and CEMS data. For improving of emission data accuracy, emission data of CEMS (named CleanSYS) equipped at 138 target workplaces were compared with those of CAPSS. As a result, $SO_x$ and $PM_{10}$ emission levels obtained by CAPSS were lower than those of CleanSYS. $SO_x$ and $PM_{10}$emission ratios were 61.5% and 71.2% lower respectively, showing the biggest gaps. On the other hand, $NO_x$ emission of CAPSS was higher by 10.4%. $SO_x$ showed the biggest difference in 'Energy industry combustion' and $NO_x$ did in 'Production Process' within the SCC category. $PM_{10}$ presented a large gap in 'Manufacturing industry combustion.' The differences in $SO_x$ between the two systems occurred because some large-size facilities lack pollution controllers or efficient pollution controllers. Based on this study, CAPSS emission database of Korea will improve accuracy through adopting CEMS emission system, which enables more efficient national atmospheric policies and workplace management.

지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구 (A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer)

  • 권영철;박진철
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

A Numerical Investigation of Indoor Air Quality with CFD

  • Sin V. K;Sun H. I
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.207-208
    • /
    • 2003
  • Increasing interest in indoor air quality (IAQ) control has been found because of its serious effect on human health. To evaluate IAQ, thermal comfort in terms of temperature and velocity distributions of indoor air has to be analyzed in detail. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In this paper, we present a discussion on the proper location of the air-conditioner in order to obtain good thermal comfort for occupant of a typical bedroom in Macao. A set of carefully designed numerical experiments is run with the Computational Fluid Dynamics (CFD) software FLOVENT 3.2 [1]. Reynolds averaged Navier-Stokes equations are solved with finite volume technique and turbulence effects upon the mean flow characteristics is modeled with the k - & model. Assumption of steady state environment is made and only convective and conductive heat transfer from the occupant and air-conditioner are being concerned.

  • PDF

에어컨 소음의 Sound Quality 평가 (Evaluation of Sound Quality of Air-conditioning Noise)

  • 전진용;유진;김수연
    • 한국소음진동공학회논문집
    • /
    • 제16권5호
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.

하절기 고등학교 교실에서 재실자의 적극적 환경조절행동이 실내환경에 미치는 영향 (Effect of Occupants' Active Behaviour of Environmental Control on Indoor Environment in Summer's High School Classroom)

  • 곽노열
    • 대한건축학회논문집:구조계
    • /
    • 제35권5호
    • /
    • pp.181-190
    • /
    • 2019
  • In high school classrooms, it is reported that ventilation is often insufficient, increasing health risks among students. Therefore, indoor air quality in school classrooms is very important in terms of students' health and learning abilities. In this study, the effect of window opening, which is a control mechanism for air control in summer high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. It was found that change rate of $CO_2$ concentration in classroom was effectively reduced by carrying out activity of opening the window by active environment control activity of occupants at break time, intermission time and cleaning time. And optimal window opening by students was presented to prevent unpleasantness and degradation of indoor air quality and the effects were analyzed.

Korean National Emissions Inventory System and 2007 Air Pollutant Emissions

  • Lee, Dae-Gyun;Lee, Yong-Mi;Jang, Kee-Won;Yoo, Chul;Kang, Kyoung-Hee;Lee, Ju-Hyoung;Jung, Sung-Woon;Park, Jung-Min;Lee, Sang-Bo;Han, Jong-Soo;Hong, Ji-Hyung;Lee, Suk-Jo
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권4호
    • /
    • pp.278-291
    • /
    • 2011
  • Korea has experienced dramatic development and has become highly industrialized and urbanized during the past 40 years, which has resulted in rapid economic growth. Due to the industrialization and urbanization, however, air pollutant emission sources have increased substantially. Rapid increases in emission sources have caused Korea to suffer from serious air pollution. An air pollutant emissions inventory is one set of essential data to help policymakers understand the current status of air pollution levels, to establish air pollution control policies and to analyze the impacts of implementation of policies, as well as for air quality studies. To accurately and realistically estimate administrative district level air pollutant emissions of Korea, we developed a Korean Emissions Inventory System named the Clean Air Policy Support System (CAPSS). In CAPSS, emissions sources are classified into four levels. Emission factors for each classification category are collected from various domestic and international research reports, and the CAPSS utilizes various national, regional and local level statistical data, compiled by approximately 150 Korean organizations. In this paper, we introduced for the first time, a Korean national emissions inventory system and release Korea's official 2007 air pollutant emissions for five regulated air pollutants.