• Title/Summary/Keyword: Air Purifier

Search Result 68, Processing Time 0.024 seconds

Development of air-sterilization purification system of fusion and composite structure using broadband-to-active photocatalyst (광대역대 활성광촉매를 활용한 융·복합 구조 공기살균정화장치 개발)

  • Yoon, Sueng-Bae;Hwang, Yun-Jung;Kim, Seung-Cheon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.147-151
    • /
    • 2019
  • Modern people spend most of their daily lives in their homes, schools, or workplaces, hospitals, shopping malls, subway stations, rooms, and parking lots. According to the survey, air quality management at the multi-use facility is less than 50% satisfied. In this study, a photocatalytic filtration system is developed by utilizing a broadband-to-active photocatalyst that utilizes a media photocatalyst filter that removes airborne germs from indoor air as well as indoor air quality and operates on visible light as well as ultraviolet light.

Characteristics of Indoor PM2.5 and the effect of air purifier and ventilation system on Indoor PM2.5 in the Knowledge Industrial Center office during the atmospheric PM2.5 warning (초미세먼지 주의보 시 지식산업센터 사무실의 실내 초미세먼지 농도 특성과 공기청정기와 환기장치의 영향)

  • Ji, Jun-Ho;Joo, Sang-Woo
    • Particle and aerosol research
    • /
    • v.16 no.3
    • /
    • pp.65-72
    • /
    • 2020
  • In this study, the indoor fine dust concentration in an office of the Korea Knowledge Industry Center was measured for about 80 hours when the concentration of atmospheric PM2.5 was very high. The effect of the operation of the air cleaner and the forced ventilation system on the indoor PM2.5 was investigated, and the particle size distribution of the indoor and outdoor particles was analyzed. When forced ventilator and air purifiers were partially used, the indoor PM2.5 concentrations were maintained between 27.7 ㎍/㎥ and 32.9 ㎍/㎥ when the atmospheric PM2.5 was 127.7 ㎍/㎥ to 141.6 ㎍/㎥ during working hours. It is more effective to operate the air purifier without operating the forced ventilation system when the concentration of the PM2.5 is high since the PM2.5 penetrating the installed filter is continuously introduced indoor from the outside.

Development of an air purification system using moss and evaluation of air purification capability for each moss (이끼를 활용한 공기정화 시스템 개발 및 이끼별 공기정화 능력 평가)

  • Ahn, DoHyun;Choi, Hyeunwoo;Lee, JongMin;Heo, SungPhil
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.3
    • /
    • pp.21-28
    • /
    • 2022
  • Fine dust enters the lungs or blood vessels through the respiratory tract through the air. Recently, due to the fine dust problem, the demand for air purifiers in Korea is also increasing rapidly. Moss is the oldest terrestrial plant, and it is known that it has the property of adsorbing and decomposing heavy metals and fine dust. To compare the effect of reducing fine dust between moss and the existing chemical filter (Hepa), a cube of 1 m3 was manufactured and the amount of fine dust reduction under a controlled environment was compared. Under the fine dust conditions, an umbrella moss filter, rat tail moss filter, feather moss filter, and silk moss filter were inserted for a total of 40 experiments, 10 times each in 4 different situations. The difference between the amount after 30 minutes was statistically significant for all filters. However, as a result of the test, it was confirmed that there was no statistically significant difference between filters for fine dust, mixed gas, CO2, and O2. In particular, it was confirmed that the previously claimed effect of oxygen generation was almost nonexistent. Through this result, it was confirmed that the reduction of fine dust is effective regardless of the species view of moss, and it is expected to replace or supplement the chemical filter of the existing air purifier through future improvement.

A Study on the Factors Affecting the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 영향을 미치는 인자에 관한 연구)

  • Chung Min-Ho;Yoo Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.956-964
    • /
    • 2005
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery The purpose of this research is to find the factors affecting the performance of paper heat exchanger for exhaust heat recovery, which can be applied directly to the conventional ventilation unit, air-purifier, and air-conditioning system. In this study, thermal performance and pressure loss of the paper heat exchanger are measured and compared at various operating conditions. The effectiveness of sensible, latent and total heat at the face velocity of 0.75 m/s are $77\%,\;47\%\;and\;57\%$ in the cooling condition and $77\%,\;59\%,\;and\;\%$ in the heating condition, respectively. The effectiveness for sensible heat is only affected by velocity. On the other hand, the effectiveness for latent heat is affected. by temperature and relative humidity.

Performance Characteristics of Propane/isobutane Mixtures in a Small Refrigeration System (프로판-이소부탄 혼합냉매를 적용한 소형 냉동시스템의 성능 특성에 관한 연구)

  • 윤원재;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.73-82
    • /
    • 2002
  • A small refrigeration system used in a water purifier was tested by employing propane/isobutane (R-290/R-6OOa) mixtures as an alternative refrigerant of R-12. The drop-in tests were performed by varying mass fraction of propane at 0.25, 0.5 and 0.75 with a change of both refrigerant charge amount and capillary tube length in order to find an optimum composition in aspect of performance and reliability of the system. As a result, the mixture of 50% propane-50% isobutane showed the best performance and reliability among them in a small refrigeration system. During steady state operations, both the COP and refrigeration capacity increased by 4% and 9%, respectively, as compared to the baseline R-12 system. In addition, the propane/isobutane (50/50) mixture system yielded advantages in the minimization of modification and redesigning of system components due to very similar saturation tempera- ture and pressure characteristics with R-12.

A Study on the Effect of Fine Dust on Household Power Consumption Using Climate Data - Focus on the Spring Season (April) and Fall Season (October) in Seoul - (기후 데이터를 활용한 미세먼지가 가정용 전력소비량에 미치는 영향 연구 - 서울지역 봄철(4월), 가을철(10월)을 중심으로 -)

  • Hwang, Hae-seog;Lee, Jeong-Yoon;Seo, Hye-Soo;Jeong, Sang
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.532-541
    • /
    • 2022
  • Purpose: The purpose of this study is to suggest that the existing power demand prediction method including power demand according to fine dust is included in the existing power consumption by using an air purifier to improve the air quality due to fine dust. Method: The method of the study was compared and analyzed using data on the concentration of fine dust in Seoul for three years, household power consumption, and climate observation, and the effect of fine dust on power consumption in Seoul was identified in April and October. Result: The power consumption of home air purifiers in Seoul due to fine dust differences between April and October was calculated to be 2,141 MWh, accounting for 3.4% of the total difference in the use of home appliances in April and October. Conclusion: The effect of fine dust on household power consumption was verified, and power demand prediction is essential for economic system operation and stable power supply, so power consumption due to fine dust should be considered as well as focusing on power consumption of existing air conditioners and heaters.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

A study of Recognition of Indoor Air Quality of Indoor Environment at School (학교 실내 환경의 실내공기질 인식에 관한 연구)

  • Hong, Eun-Ju;Kim, Jung-Duck;Jeon, Young-Taek;Lee, Che-Won;Moon, Jeong-Suk;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.51-64
    • /
    • 2007
  • This research, selected for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003, in order to study of Recognition of Indoor Air Quality of Indoor Environment at School. we used Questionnaire for 193 health teachers, 41 teachers, and 1,359 students. The results of study are as follows. 1. To the question 'Currently Were you damage caused by classroom air?', showed that worry class teachers more than students with 43.9% of class teachers, 35.9% of health teachers and 23.5% of students. 2. To the question 'What would be an efficient way to manage classroom sanitation?', 50% of class teachers, 40.5% of health teachers and 47.4% of students wanted 'installation of air purifier.' 3. To the question 'How are you getting information about indoor air pollution?', showed that all of 3 groups get information through on TV. 4. According to survey, Health teachers who act as health supervisors appeared to have more prior knowledge air quality than class teachers and students. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. Therefore, these results suggested that a logical and systematic education program for students about the importance of indoor air quality should be carried out.

Monitoring of Microbial Contamination in Air Purifier for Preventing Cross-contamination (교차오염방지를 위한 공기정화제품에서 미생물 오염도 분석)

  • Yeom, Seung-Mok;Kim, Young-Mog;Lee, Myung-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • Many atmospheric pollutants including chemical agents, house dust, and microorganisms cause building-related illnesses through respiration in humans. This study was conducted to analyze the profiles of microbial pollutants in air purifiers used in home, office and playschool. Dominant eleven species of microorganisms were isolated and identified in environmental air and air purifiers. Among them, Staphylococcus sp., Micrococcus sp. and Bacillus sp. are the most dominant species. By phylogenetic analysis of the 16S rRNA gene, the dominant bacteria were identified as Staphylococcus epidermidis, Micrococcus luteus and Bacillus epidermidis, respectively. It has been known that these bacterial species are closely related with food spoilage and human infectious disease. Thus, these results indicate that microbial pathogens related with human illnesses through respiration will be contaminated in air purifiers and also need to develop a method to control those of pathogens for human health.

A Study on the Health Management of Dental Technicians and Their Awareness of the Same (치과기공사들의 건강관리 실태 및 인식수준에 관한 조사 연구)

  • Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.113-128
    • /
    • 2000
  • The purpose of this study was to serve as a basis for the development of dental technology and for creating a condition that dental technicians could work with pride and right values, by examining what problems there were in their health care, what they thought about them, and how the problems could be solved, The findings of this study were as below: 1. The most serious and harmful element in dental technology workshop was a dust(57.5%) and a noise(33.3%). 2. Approximately 99.0% of the dental technicians investigated made a complain of air pollution caused by noise. Their opinion on a possible measure to remove noise air pollution was that the noise-generating machine should be replaced(64.1%) or that it should be isolated(28.8%). 3. 76.0% complained air pollution cause by dust deteriorates their working efficiency. As a way to eliminate it, they suggested a dust chamber(35.3%) or an air cleaner(27.5%) should be installde. 4. About 80% made a complain of gas air pollution. The most common related symptom was a headache(56.9%). They thought that gas-generating machine should be isolated(39.9%) or that an air purifier should be prepared(33.3%). 5. The largest impact of heat and light on their body was weakening their eyesight(56.9%). 47.1% got burn once though four times, and 34.3% did five times or more. The way to prevent them was to install an automatic casting machine(66.0%) or use protective glasses(28.1%). 6. Approximately 47.7% were considering a change of occupation, and the most common reason was heavy work(23.5%), followed by poor prospect(21.6%) and working environment(19.0%) in the order named. 7. 88.9% responded they were likely to have an occupational disease. Their idea about the proper frequency of regular health examination was once a year(53.6%), or once per every six months(41.8%). 8. The field they were most interested in was health care(39.2%), followed by academic research activities(31.4%). This fact indicated it's most urgently required to improve their working environment.

  • PDF