• 제목/요약/키워드: Air Pollutants Dispersion

검색결과 80건 처리시간 0.02초

고-기상 유해물질 대기확산에 관한 수치해석 (A Numerical Study on the Toxic Gaseous and Solid Pollutant Dispersion in an Open Atmosphere)

  • 이선경;송은영;장동순
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.146-154
    • /
    • 1994
  • A series of numerical calculations are performed in order to investigate the dispersion mechanism of toxic gaseous and solid pollutants in extremely short-term and short range. The calculations are carried out in an open space characterized by turbulent boundary layer. The simulation is made by the use of numerical model, in which a control-volume based finite difference method is used together with the SIMPLEC algorithm for the resolution of the pressure-velocity coupling problem. The Reynolds stresses are solved by two-equation, k-$\varepsilon$ model modified for buoyancy. The major parameters consider-ed in this study are temperature, velocity and Injection height of toxic gases, environmental conditions such as temperature and velocity of free stream air, and topographic factor. The results are presented and discussed in detail. The flow field is commonly characterized by the formation of a strong recirculation zone due to the upward motion of the hot toxic gas and ground shear stress. The driving force of the upward motion is explained by the effect of thermal buoyancy of hot gas and the difference of inlet velocity between toxic gas and free stream.

  • PDF

Modeling of SO$_2$ Emissions from Yatagan Power Plant

  • Im, Ulas;Yenigun, Orhan
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.69-72
    • /
    • 2003
  • The meteorological model, CALMET, and its plume dispersion model, CALPUFF, were used in order to simulate the dispersion of $SO_2$ emitted from Yatagan Power Plant and its effect on Yatagan district in the episodic event on December 2 and 3, 2000. It is found that south westerly and light winds and the nighttime surface inversion layers lead to accumulation of pollutants over Yatagan district. The results are compared with the measurements done by Local Environmental Authorities of Mu la. The simulation results indicate that the maximum ground level concentrations were found northeast from the source, which agrees with experimental measurement. On the other hand, the magnitude of results obtained with the model shows some differences compared with experimental measurements.

  • PDF

A WSR-88D Radar Observation of Chaff Transport and Diffusion in Clear Sky

  • Lee, Dong-In
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권4호
    • /
    • pp.263-271
    • /
    • 2000
  • To investigate the distribution of air pollutants dispersion in the horizontal wind fields, a chaff release experiment was carried out by an airplane. The temporal and spatial variations of a chaff plume from an elevated point source using the WSR-88D(NEXRAD) radar. The observed profiles of radar reflectivity were compared with the Gaussian diffusion model at slightly unstable atmospheric condition. The present study shows that the distributions of radar reflectivity from chaffs and their concentration by the model are in general agreement with time variation. The dispersion coefficients in downwind($\sigma$(sub)x) and crosswind($\sigma$(sub)y) spread data exceeded what has generally been found at Pasquill and Brigg\`s estimates. As a result, it was clearly shown that horizontal and vertical diffusion coefficients are more accurately determined as compared with theoretical coefficients. At longer diffusion distances(than 10km), a radar observation provided the determination of maximum range and diffusion height more qualitatively, too.

  • PDF

광화학 확산모델 적용을 위한 수도권지역의 대기오염물질 배출량 산출 (Estimation of Air Pollutant Emissions for the Application of Photochemical Dispersion Model in the Seoul Metropolitan Area)

  • 이종범;김용국;김태우;방소영;정유정
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.123-135
    • /
    • 1997
  • An air pollutant emission inventory system for the input preparations of photochemical dispersion model was developed. Using the system, anthropogenic emissions as well as biogenic emissions in the Seoul metropolitan area were calculated. Anthropogenic emission by fuel combustion using regional cosumption data, and the laundries and so forth was estimated. The biogenic emission was estimated based upon meteorological data and the distribution of land use type in the study area. The anthropogenic emission of pollutants was highest in Seoul, and the second highest in Inchon. TSP and $SO_2$ were found large quantities during the winter due to increased consumption of heating oil. NOx and THC were emitted without seasonal variation. Among biogenic emissions, PAR was very common while NO was the least common. PAR, OLE, and ALD2 were emitted in large volumes in coniferous forest areas, while ISOP was emitted in deciduous forest areas. Generally, most biogenic emissions increased during daytime, and peaked between oen and two o'clock. Because of strong solar radiation, emission during the summer was high. Biogenic NO emissions were found to be lower compared to anthropogenic emissons, and other VOC was indicated relatively high. In the study area, among biogenic emissions PAR was found to be 3 times, OLE 8 times,and ALD2 12 times more common than among anthropogenic emissions.

  • PDF

고-기상 독성오염물질 단기 대기확산에 관한 수치해석적 연구 : 화학종, 온도, 상대속도 (A Numerical Study on the Short-term Dispersion of Toxic Gaseous and Solid Pollutant in an Open Atmosphere : Chemical Species, Temperature, Relative Velocity)

  • 나혜령;이은주;장동순;서영태
    • 한국안전학회지
    • /
    • 제10권3호
    • /
    • pp.68-80
    • /
    • 1995
  • A series of parametric calculations have been performed in order to investigate the short-term and short-range plume and puff behavior of toxic gaseous and solid pollutant dispersion in an open atmosphere. The simulation is made by the use of the computer program developed by this laboratory, in which a control-volume based finite-difference method is used together with the SIMPLEC algorithm for the resolution of the pressure-velocity coupling appeared In Wavier-Stokes equation. The Reynolds stresses are solved by the standard two-equation k-$\varepsilon$ model modified for buoyancy together with the RNG(Renormalization Group) k-$\varepsilon$ model. The major parameters considered in this calculation are pollutant gas density and temperature, the relative velocity of pollutants to that of the surrounding atmospheric air, and particulate size and density together with the height released. The flow field is typically characterized by the formation of a strong recirculation region for the case of the low density gases such as $CH_4$ and air due to the strong buoyancy, while the flow is simply declining pattern toward the downstream ground for the case of heavy molecule like the $CH_2C1_2$and $CCl_4$, even for the high temperature, $200^{\circ}C$. The effect of gas temperature and velocity on the flow field together with the particle trajectory are presented and discussed in detail. In general, the results are physically acceptable and consistent.

  • PDF

장기간 대기오염 및 기상측정 자료 (2000~2009)를 이용한 PM10과 NO2의 강수세정 기여율과 바람분산 기여율의 정량적 추정연구 (Quantitative Estimation of Precipitation Scavenging and Wind Dispersion Contributions for PM10 and NO2 Using Long-term Air and Weather Monitoring Database during 2000~2009 in Korea)

  • 임득용;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.325-347
    • /
    • 2012
  • Long-term air and weather data monitored during the period of 2000 to 2009 were analyzed to quantitatively estimate the precipitation scavenging and wind dispersion contributions of ambient $PM_{10}$ and $NO_2$ in Korea. Both air pollutants and meteorological data had been respectively collected from 120 stations by the Ministry of Environment and from 20 weather stations by the Korea Meteorological Administrations in all parts of Korea. To stochastically identify the relation between a meteorological factor and an air pollutant, we initially defined the SR (scavenging ratio) and the DR (dispersion ratio) to separately calculate the precipitation and wind speed effects on the removal of a specific air pollutant. We could then estimate the OSC (overall scavenging contribution) and the ODC (overall dispersion contribution) with considering sectoral precipitation and wind speed probability density distributions independently. In this study, the SRs for both $PM_{10}$ and $NO_2$ were generally increased with increasing the amounts of precipitation and then the OSCs for $PM_{10}$ and $NO_2$ were estimated by 22.3% and 15.7% on an average in Korea, respectively. However, the trend of the DR was quite different from that of SR. The DR for $PM_{10}$ was increased with increasing wind speed up to 2.5 m/s and further the DR for $NO_2$ showed a minimum in the range of $1<WS{\leq}1.5$. The ODCs for $PM_{10}$ and $NO_2$ were estimated by 14.9% and 1.0% in Korea, respectively. Finally, we have also provided an interesting case study observed in Seoul.

추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 추적기체의 확산특징과 CALPUFF 모델에 의한 모사 (Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - Simulation by CALPUFF Dispersion Model and Diffusion Feature of Tracer Gases)

  • 이종범;김재철;이강웅;노철언;김혜경
    • 한국대기환경학회지
    • /
    • 제23권4호
    • /
    • pp.405-419
    • /
    • 2007
  • A series of tracer experiments for the evaluation of atmospheric dispersion was performed over the urban area of Seoul using two inert, non-deposition perfluorocarbon (PMCH and m-PDCH) gases during three years campaign on 2002, 2003 and 2005. 30 sampling sites for collecting these tracers were located along two arcs of 2.5 and 5 kilometers downwind from the release point. About ten measurements which each lasted for 2 hours or 4 hours were made over the two consecutive days during each campaign. CALPUFF and MM5 meteorological model were applied to evaluate the urban dispersion in detail. Size of Modeling domain was $27\;km{\times}23\;km$ and the fine nest in the modeling domain had a grid size of 0.5 km. The results showed that CALPUFF dispersion model had a tendency to estimate tracer concentrations about $2{\sim}5$ times less than those of ambient samples under many conditions. These consistent inaccuracy in urban dispersion was attributed to inherent inaccuracy and lack of details in terrain data at urban area.

포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로- (Health and Environmental Risk Assessment of Pollutants in Pohang)

  • 정종현;최원준;임헌호;손병현
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2719-2726
    • /
    • 2010
  • 본 연구는 포항지역 환경오염물질의 보건 환경 위해성 평가를 위한 기초연구의 일환이며, 이를 위하여 포항시에 소재한 지역대기자동측정 자료를 이용하여 연별, 계절별 $PM_10$ 농도분포에 대한 현황, 기상특성 및 오염물질 농도분포 분석을 수행하였고, 대기확산 모델(CALPUFF)을 이용하여 농도분포 특성에 대해 정성적, 정량적으로 확인하였다. 포항지역의 $PM_10$ 농도분포를 확인한 결과, 포항지역의 계절별 $PM_10$ 평균농도는 봄($75.7{\mu}g/m^3$)>여름($56.8{\mu}g/m^3$)>겨울($53.6{\mu}g/m^3$) >가을($52.7{\mu}g/m^3$) 순으로 봄에는 빈번히 발생하는 황사의 영향으로 높은 농도를 나타내었다. 포항지역 오염원별 $PM_10$ 배출량은 점오염원 62%>이동오염원 33%>면오염원 5% 순이며, 점오염원 중 전체 97%가 철강산업인 제철제강업에서 발생되었다. 포항지역은 $PM_10$의 영향을 많이 받고 있는 지역으로 포항철강공단지역에 대한 환경오염물질 원인배출원에 대한 감시체계의 보완 및 집중관리와 함께 포항지역 주민의 건강 보호를 위하여 보건 및 환경에 악영향을 미치는 위해인자 및 오염물질을 원천적으로 차단하는 작업이 지속적으로 수행되어야 할 시점이다.

서울 일부지점의 대기오염 농도와 기상인자의 관련성 연구 (A Study on the Relationship of Air Pollution and Meteorologic Factors in a Specific Site)

  • 신찬기;김윤신
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.141-152
    • /
    • 1992
  • Simple correlation analysis, factor analysis, and multi-verite analysis have been performed to analyze the relationship between air pollution and meteorological factors for air pollution and meteorological data measured at Kwanghwamun in Seoul during the period of one year (January 1990" December 1990). As a result of simple correlation and factor analysis, $SO_2$, TSP and CO concentrations have shown high negative correlation with temperature and among these indicating that these are related with pollutants emission trend based upon heating fuel usage. Ozone has a good correlation with solar radiation and relative humidity to have a closed relation with $0_3$ generation reaction mechanism. The result of multi-variate correlation analysis shows that the concentration of $SO_2$ and CO are adequate for correlation model with ambient temperature and wind speed and 0$_{3}$ concentrations are adequate for that with solar radiation and wind speed. $SO_2$ and CO levels are considered to be affected first of all by heating fuel usage as a emission source and wind speed as a dispersion effect. The $SO_2$ concentration in the condition that the temperature fall below zero is explained by multiplicative model with wind speed, only one variable.

  • PDF

건축공간에서 공기 감염균 확산을 해석하기 위한 추적가스 고찰과 농도에 따른 감염 위험성 예측 연구 (A Inquiry of Tracer Gas for Analysis of Dispersion and Prediction of Infection Possibility according to Airborne Viral Contaminants)

  • 임태섭;강승모;김병선
    • 한국실내디자인학회논문집
    • /
    • 제18권3호
    • /
    • pp.102-113
    • /
    • 2009
  • The SARS virus began to appear and spread in North America and Southeast Asia in the early 2000' s, infecting and harming many people. In the process of examining the causes for the virus, studies on the airborne SARS virus and the way it spread were carried out mainly in the medical field. In the field of architecture, studies were done on the diffusion of air pollutants in buildings using gases such as $CO_2$, $N_2O$, or $SF_6$, but research on virus diffusion was limited. There were also explanations of only the diffusion process without accurate information and discussion on virus characteristics. The aim of this study is to analyze the physical characteristics of airborne virus, consider the possibility of using coupled analysis model and tracer gas for analyzing virus diffusion in building space and, based on reports of how the infection spread in a hospital where SARS patients were discovered, analyze infection risk using tracer gas density and also diffusion patterns according to the location, shape, and volume of supply diffusers and exhaust grilles. This paper can provide standards and logical principles for evaluating various alternatives for making decisions on vertical or horizontal ward placement, air supply and exhaust installation and air volumes in medium or high story medical facilities.