• Title/Summary/Keyword: Air Layer

Search Result 1,862, Processing Time 0.028 seconds

Numerical Analysis of Natural Convection inside Spray Coating Room on Temperature Distributions (자연대류를 고려한 스프레이 코팅 룸에서의 온도분포 해석)

  • Kim, Nam Woong;Kim, Bo-Seon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.425-430
    • /
    • 2019
  • Zinc coatings are widely used because of their environmental friendliness and high performance. In general, the coating temperature is a major factor in determining the coating layer thickness and coating quality. In the case of a zinc coating, a uniform and appropriate coating temperature is required. In this study, a thermal flow simulation of the air flow was performed to analyze the temperature distribution of a zinc spray coating room in a natural convection state. Using SolidWorks, modeling was performed for two spray coating rooms, a preheating room, and a drying room, and a thermal flow coupled analysis was performed using ANSYS-FLUENT. As a result of the analysis, the temperature distribution characteristics in the spray coating rooms were determined. It was found that the present temperature was below the target temperature of $25^{\circ}C$. Simulations were conducted for two different boundary conditions (one with a heater added and another with the open part closed). The simulation results show that the method of closing the open part is better than adding the heater.

Diversity of phytoplankton species in Cheonjin Lake, northeastern South Korea

  • Kim, Han Soon
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.240-258
    • /
    • 2018
  • Background: Several investigations carried out from large brackish lagoons in South Korea. However, no studies have yet examined phytoplankton in lagoons that changed to freshwater, such as Cheonjin Lake. The present study examined the algae from Cheonjin Lake. Methods: Samples were collected at monthly inetrvals from May 2017 to April 2018, from the surface layer using a plankton net (mesh size $20{\mu}m$), and sequeezing submerged macrophytes. Microscopic examinations were conducted at a magnification of 200 to 1000x using a Zeiss microscope (Axio Imager. A2), and photographs were taken with an AxioCam HRC camera. Silica-scaled samples of Chrysophyta for SEM were placed on coverglass, air dried, coated with gold, and then examined with a Hitachi SV8220 SEM. Results: A total of 376 taxa from six major algal groups (Chlorophyta, Chrysophyta, Euglenophyta, Cyanophyta, Dinophyta, and Cryptophyta) were identified. Among these algae, 28 taxa of desmids, 9 taxa of Euglenophyceae, 4 taxa of Chlorophyceae, 2 taxa of Chrysophyceae, and 1 taxon of Xanthophyceae are reported for the first time in Korea. A new species, Cosmarium hexagonum sp. nov was described. The phytoplankton communities were characterized by an abundance of Desmids (within Charophyceae) accounted for 148 taxa from 22 genera. Species richness were particularly high in the Autumn. Conclusion: In this study, a total 376 taxa of 148 desmids (Charophyceae), Chlorophyceae (103 taxa), Chrysophyceae (53 taxa), Euglenophyta (49 taxa), Dinophyta (8 taxa), and Cryptophyta (2 taxa) were identified from Cheonjin Lake. Twenty-eight taxa of desmids including a new species (Cosmarium hexagonum sp. nov.), 9 taxa of Euglenophyceae, 4 taxa of Chlorophyceae, 2 taxa of Chrysophyceae, and 1 taxon of Xanthophyceae were newly recorded in Korea.

Effects of different wind deflectors on wind loads for extra-large cooling towers

  • Ke, S.T.;Zhu, P.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.28 no.5
    • /
    • pp.299-313
    • /
    • 2019
  • In order to examine the effects of different wind deflectors on the wind load distribution characteristics of extra-large cooling towers, a comparative study of the distribution characteristics of wind pressures on the surface of three large cooling towers with typical wind deflectors and one tower without wind deflector was conducted using wind tunnel tests. These characteristics include aerodynamic parameters such as mean wind pressures, fluctuating wind pressures, peak factors, correlation coefficients, extreme wind pressures, drag coefficients and vorticity distribution. Then distribution regularities of different wind deflectors on global and local wind pressure of extra-large cooling towers was extracted, and finally the fitting formula of extreme wind pressure of the cooling towers with different wind deflectors was provided. The results showed that the large eddy simulation (LES) method used in this article could be used to accurately simulate wind loads of such extra-large cooling towers. The three typical wind deflectors could effectively reduce the average wind pressure of the negative pressure extreme regions in the central part of the tower, and were also effective in reducing the root of the variance of the fluctuating wind pressure in the upper-middle part of the windward side of the tower, with the curved air deflector showing particularly. All the different wind deflectors effectively reduced the wind pressure extremes of the middle and lower regions of the windward side of the tower and of the negative pressure extremes region, with the best effect occurring in the curved wind deflector. After the wind deflectors were installed the drag coefficient values of each layer of the middle and lower parts of the tower were significantly higher than that without wind deflector, but the effect on the drag coefficients of layers above the throat was weak. The peak factors for the windward side, the side and leeward side of the extra-large cooling towers with different wind deflectors were set as 3.29, 3.41 and 3.50, respectively.

Interpretation and Comparison of High PM2.5 Characteristics in Seoul and Busan based on the PCA/MLR Statistics from Two Level Meteorological Observations (두 층 관측 기상인자의 주성분-다중회귀분석으로 도출되는 고농도 미세먼지의 부산-서울 지역차이 해석)

  • Choi, Daniel;Chang, Lim-Seok;Kim, Cheol-Hee
    • Atmosphere
    • /
    • v.31 no.1
    • /
    • pp.29-43
    • /
    • 2021
  • In this study, two-step statistical approach including Principal Component Analysis (PCA) and Multiple Linear Regression (MLR) was employed, and main meteorological factors explaining the high-PM2.5 episodes were identified in two regions: Seoul and Busan. We first performed PCA to isolate the Principal Component (PC) that is linear combination of the meteorological variables observed at two levels: surface and 850 hPa level. The employed variables at surface are: temperature (T2m), wind speed, sea level pressure, south-north and west-east wind component and those at 850 hPa upper level variables are: south-north (v850) and west-east (u850) wind component and vertical stability. Secondly we carried out MLR analysis and verified the relationships between PM2.5 daily mean concentration and meteorological PCs. Our two-step statistical approach revealed that in Seoul, dominant factors for influencing the high PM2.5 days are mainly composed of upper wind characteristics in winter including positive u850 and negative v850, indicating that continental (or Siberian) anticyclone had a strong influence. In Busan, however, the dominant factors in explanaining in high PM2.5 concentrations were associated with high T2m and negative u850 in summer. This is suggesting that marine anticyclone had a considerable effect on Busan's high PM2.5 with high temperature which is relevant to the vigorous photochemical secondary generation. Our results of both differences and similarities between two regions derived from only statistical approaches imply the high-PM2.5 episodes in Korea show their own unique characteristics and seasonality which are mostly explainable by two layer (surface and upper) mesoscale meteorological variables.

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

A Study on Intermittent Demand Forecasting of Patriot Spare Parts Using Data Mining (데이터 마이닝을 이용한 패트리어트 수리부속의 간헐적 수요 예측에 관한 연구)

  • Park, Cheonkyu;Ma, Jungmok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.234-241
    • /
    • 2021
  • By recognizing the importance of demand forecasting, the military is conducting many studies to improve the prediction accuracy for repair parts. Demand forecasting for repair parts is becoming a very important factor in budgeting and equipment availability. On the other hand, the demand for intermittent repair parts that have not constant sizes and intervals with the time series model currently used in the military is difficult to predict. This paper proposes a method to improve the prediction accuracy for intermittent repair parts of the Patriot. The authors collected intermittent repair parts data by classifying the demand types of 701 repair parts from 2013 to 2019. The temperature and operating time identified as external factors that can affect the failure were selected as input variables. The prediction accuracy was measured using both time series models and data mining models. As a result, the prediction accuracy of the data mining models was higher than that of the time series models, and the multilayer perceptron model showed the best performance.

The Mechanical Properties and Biocompatibility of Functionally Graded Coatings(FGC) of Hydroxyapatite(HA) and Metallic Powders - Functionally Gradient Coatings of Thermal Spray in Air- (Hydroxyapatite (HA)와 금속 분말 경사 코팅의 기계적 특성 및 생체 적합성 - 대기 열용사 경사코팅 -)

  • Kim, Eun-Hye;Kim, Yu-Chan;Han, Seung-hee;Yang, Seok-Jo;Park, Jin-Woo;Seok, Hyun-Kwang
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.1
    • /
    • pp.13-20
    • /
    • 2009
  • This work presents functionally graded coatings (FGC) of hydroxyapatite (HA) and metallic powders on Ti-6Al-4V implants using plasma spray coating method. HA has been the most frequently used coating material due to its excellent compatibility with human bones. However, because of the abrupt changes in thermomechanical properties between HA and the metallic implant across an interface, and residual stress induced on cooling from coating temperture to room temperature, debonding at the interface occurs in use sometimes. In this work, FGC of HA and Ti or Ti-alloy powders is made to mitigate the abrupt property changes at the interface and the effect of FGC on residual stress release is investigated by evaluating the mechanical bond strength between the implant and the HA coating layers. Thermal annealing is done after coating in order to crystallize the HA coating layer which tends to have amorphous structure during thermal spray coating. The effects of types and compositional ratio of metallic powders in FGC and annealing conditions on the bond strength are also evaluated by strength tests and the microstructure analysis of coating layers and interfaces. Finally, biocompatibility of the coating layers are tested under ISO 10993-5.

Applying Fire Risk Analysis to Develop Fire-safe Modular Walls: Guidance to Material Selection, Design Approach and Construction Method

  • Lim, Seokho;Chung, Joonsoo;Kim, Mihyun Esther
    • Architectural research
    • /
    • v.24 no.2
    • /
    • pp.21-27
    • /
    • 2022
  • For the past decade, South Korea had experienced catastrophic building fires, which resulted in consider-ably high number of casualties. This motivated research to develop fire-safe wall assemblies. In this study Fire Risk Analysis (FRA) is conducted as part of the project designing phase to ensure fire safety of the final product. Traditional approach was to consider fire performance at the end of the designing stage, when PASS/FAIL fire test results are required to be submitted to the Authority Having Jurisdiction (AHJ). By applying a fire risk analysis to guide the designing phase, overall fire safety of a wall assembly can be achieved more systematically as conducting FRA allows designers to clearly identify elements that are more vulnerable to fire and simply replace them with other practical options. Severity of fire risk is determined by considering the fire hazards of a wall assembly such as the exterior layer, insulation, vertical connectivity, and external ignition sources (e.g., photovoltaic panels). Frequency of fire risk is assessed based on the factors affecting fire likelihood, which are air cavity and fire-stopping applied in the design, and random design changes occurring during on-site construction. Fire risk matrix is proposed based on these fire risk factors and efforts to reduce the fire risk level associated with the wall assembly are given by systematically assessing the fire risk factors identified from fire risk analysis. Current study demonstrates how fire risk analysis can be applied to develop fire-safe walls by reducing the relevant fire risks- both severity and frequency.

The effects of activated cooler power on the transient pressure decay and helium mixing in the PANDA facility

  • Kapulla, R.;Paranjape, S.;Fehlmann, M.;Suter, S.;Doll, U.;Paladino, D.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2311-2320
    • /
    • 2022
  • The main outcomes of the experiments H2P6 performed in the thermal-hydraulics large-scale PANDA facility at PSI in the frame of the OECD/NEA HYMERES-2 project are presented in this article. The experiments of the H2P6 series consists of two PANDA tests characterized by the activation of three (H2P6_1) or one (H2P6_2) cooler(s) in an initially stratified and pressurized containment atmosphere. The initial stratification is defined by a helium-rich region located in the upper part of the vessel and a steam/air atmosphere in the lower part. The activation of the cooler(s) results i) in the condensation of the steam in the vicinity of the cooler(s), ii) the corresponding activation of large scale natural circulation currents in the vessel atmosphere, with the result of iii) the re-distribution and mixing of the Helium stratification initially located in the upper half of the vessel and iv) the continuous pressure decay. The initial helium layer represents hydrogen generated in a postulated severe accident. The main question to be answered by the experiments is whether or not the interaction of the different, localized cooler units would be important for the application of numerical methods. The paper describes the initial and boundary conditions and the experimental results of the H2P6 series with the suggestion of simple scaling laws for both experiments in terms of i) the temperature difference(s) across the cooler(s), ii) the transient steam and helium content and iii) the pressure decay in the vessel. The outcomes of this scaling indicate that the interaction between separate, closely localized units does not play a prominent role for the present experiments. It is therefore reasonable to model several units as one large component with equivalent heat transfer area and total water flow rate.

A Comparative Anatomical Study of Saururus chinensis (Lour.) Baill. and Houttuynia cordata Thunb. (Saururaceae) (삼백초와 약모밀의 내부형태 비교 연구)

  • Yang, Sungyu;Choi, Goya
    • The Korea Journal of Herbology
    • /
    • v.33 no.3
    • /
    • pp.11-18
    • /
    • 2018
  • Objectives : Saururus chinensis and Houttuynia cordata (Saururaceae) are perennial herbs using for medicinal purposes in Korea. The objectives of this study are to compare anatomical key characters between two medicinal plants and to provide fundamental information for the identification of two herbal medicines by using anatomical features. Methods : Cross-sections of root, rhizome, stem, petiole, and leaf for each species were observed in this study. Materials were analyzed through dehydration, paraffin embedding and micro-sectioning, and double staining with Safranin O and Fast-Green FCF. Observations of permanent preparation were conducted using light microscope. Results : S. chinensis and H. cordata were distinguished with anatomical differentiations; Idioblasts with essential oil were scattered in the parenchyma cell of cortex, pith, and phloem of S. chinensis, on the other hand, in H. cordata, idioblasts were distributed ring-shaped in the cortex of the root. S. chinensis had two cycles of vascular bundles in the stem while H. cordata had one cycle. Hypodermis layer was conspicuous in a stem of H. cordata, crystals were observed the only parenchyma in a stem of S. chinensis, and epidermal oil cells were developed in the epidermis of H. cordata. S. chinensis had air cavity at the cortex and pith of the stem. The shape of cross-section was polygonal in the stem of S. chinensis and was circular in the stem of H. cordata. Conclusions : We investigated anatomical study of Korean S. chinensis and H. cordata. To identify two herbal medicines, we considered main anatomical features and provided identification key here.