• 제목/요약/키워드: Air Integration

검색결과 266건 처리시간 0.025초

300MW 태안 IGCC 플랜트 종합성능 특성 (Overall Performance characteristic for 300MW Taean IGCC Plant)

  • 김학용;김재환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.129.2-129.2
    • /
    • 2010
  • As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.

  • PDF

IGCC 발전 플랜트에서 복합발전공정-공기분리장치의 연계에 관한 열역학적 성능 평가 (Thermodynamic Performance Evaluation of an Integration Design between the Combined-cycle and Air Separation Unit in an IGCC Power Plant)

  • 원온누리;김현정;박성구;나종문;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.49-51
    • /
    • 2012
  • In this paper, the integration issue, such as an air-side integration design between the gas turbine and air separation unit, is described and analyzed by the exergy and energy balance of the combined-cycle power block in an IGCC power plant. The results showed that the net power of the system was almost same, but that of the gas turbine was decreased as the integration degree increased. The highest exergy loss was occurred in the combustor of gas turbine, which was affected by the chemical reaction, heat conduction, mass diffusion, and viscous dissipation.

  • PDF

슬라이딩 섭동 관측기를 이용한 에어셀과 반능동 서스펜션의 통합 제어 (Integration Control of Air-Cell Seat and Semi-active Suspension Using Sliding Perturbation Observer Design)

  • 유기성;윤정주;이민철;유완석
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.159-169
    • /
    • 2004
  • In this study, integration control of air-cell seat and semi-active suspension is proposed to minimize the road-tyre force which can cause uncomfortable feeling to rider. The proposed integration control with sliding perturbation observer is consisted of air-cell seat control which uses the force generated by air-cell and the sky-hook control. The air-cell seat itself has been modeled as a 1 degree of freedom spring-damper system. The actual characteristics of the air-cell have been analyzed through experiments. In this paper, we introduces a new robust motion control algorithm using partial state feedback for a nonlinear system with modelling uncertainties and external disturbances. The major contribution of this work is the development and design of robust observer for the state and the perturbation. The combination skyhook controller and air-cell controller using the observer improves control performance, because of the robust routine called Sliding Observer Design for Integration Control of Air-Cell Seat and Semi-active Suspension. The simulation results show a high accuracy and a good performance.

철도 산업의 공기 질 데이터베이스 연합형 통합을 위한 지능형 데이터 거버넌스 (Intelligent Data Governance for the Federated Integration of Air Quality Databases in the Railway Industry)

  • 김민정;원종운;박상찬;박가영
    • 품질경영학회지
    • /
    • 제50권4호
    • /
    • pp.811-830
    • /
    • 2022
  • Purpose: In this paper, we will discuss 1) prioritizing databases to be integrated; 2) which data elements should be emphasized in federated database integration; and 3) the degree of efficiency in the integration. This paper aims to lay the groundwork for building data governance by presenting guidelines for database integration using metrics to identify and evaluate the capabilities of the UK's air quality databases. Methods: This paper intends to perform relative efficiency analysis using Data Envelope Analysis among the multi-criteria decision-making methods. In federated database integration, it is important to identify databases with high integration efficiency when prioritizing databases to be integrated. Results: The outcome of this paper aims not to present performance indicators for the implementation and evaluation of data governance, but rather to discuss what criteria should be used when performing 'federated integration'. Using Data Envelope Analysis in the process of implementing intelligent data governance, authors will establish and present practical strategies to discover databases with high integration efficiency. Conclusion: Through this study, it was possible to establish internal guidelines from an integrated point of view of data governance. The flexiblity of the federated database integration under the practice of the data governance, makes it possible to integrate databases quickly, easily, and effectively. By utilizing the guidelines presented in this study, authors anticipate that the process of integrating multiple databases, including the air quality databases, will evolve into the intelligent data governance based on the federated database integration when establishing the data governance practice in the railway industry.

무인항공기 이중화 대기자료시스템 설계 및 통합 연구 (Design and Integration of a Dual Redundancy Air Data System for Unmanned Air Vehicles)

  • 원대연;윤성훈;이홍주;홍진성;황선유;임흥식;김태겸
    • 한국군사과학기술학회지
    • /
    • 제23권6호
    • /
    • pp.639-649
    • /
    • 2020
  • Air data systems measure airspeed, pressure altitude, angle of attack and angle of sideslip. These measurements are essential for operating flight control laws to ensure safe flights. Since the loss or corruption of air data measurements is considered as catastrophic, a high level of operational reliability needs to be achieved for air data systems. In the case of unmanned air vehicles, failure of any of air data sensors is more critical due to the absence of onboard pilot decision aid. This paper presents design of a dual redundancy air data system and the integration process for an unmanned air vehicle. The proposed dual-redundant architecture is based on two independent air data probes and redundancy management by central processing in two independent flight control computers. Starting from unit testing of single air data sensor, details are provided of system level tests used to meet overall requirements. Test results from system integration demonstrate the efficiency of the proposed process.

극초음속 공기반응의 수치해석적 특성과 부분 내재적 적분법 적용 (Numerical Characteristics of Hypersonic Air Chemistry and Application of Partially Implicit Time Integration Method)

  • 김성룡;옥호남;라승호;김인선
    • 한국항공우주학회지
    • /
    • 제31권7호
    • /
    • pp.1-8
    • /
    • 2003
  • 본 논문은 극초음속 유동과 공력가열 해석에서 나타나는 공기 반응의 수치해석적 특징을 다루고 공기반응을 효율적으로 해석하는 부분 내재적 적분법을 공기반응에 적용하였다. 안정적 계산을 위해 화학반응 자코비안이 필수적임을 밝혔으며 자코비안의 양의 실수 특성치로 인한 수치기법의 경직성은 일반적인 연소반응에 비하여 미약하였다. 공기반응에서 부분 내재적 적분법은 화학종 순서의 종속성이 없었으며 완전 내재적 적분법과 동일한 수렴율과 계산 결과를 보였다. 극초음속 유동해석에 부분 내재적 적분법을 적용하면 전체 연산 시간이 감소되었다.

적분형 초음파 유량계를 이용한 MPI 엔진의 비정상상태 공연비 제어 (A/F Control of an MPI Engine on Transient Conditions with an Intergration type Ultrasonic Flow Meter)

  • 김중일;장준석;고상근
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.36-47
    • /
    • 1999
  • Three-way catalyst converter, cleaning up the exhaust gas contamination of SI engine, has the best efficiency when A/F ratio is near the stoichiometry . The feedback control using oxygen sensors in the exhaust manifold has limits caused by the system delays. So the accurate measurement of air flow rate to an engine is essential to control the fuel injection rate especially on transient condition like the rapid throttle opening and closing. To measure the rapid change of flow rates. the air flow meter for the engine requires quick response, flow reversal detection, and linearity . Tjhe proposed integration type air flow meter (IFM), composed of an ultrasonic flow meter with an integration circuit, has significantly improved the measurement accuracy of air mass inducted through the throttle body. The proposed control method estimated the air mass at the cylinder port using the measured air mass at the throttle . For the fuel dynamic model, the two constant fuel model is introduced . The control parameters from air and fuel dynamics are tuned to minimize the excursion of the air fuel ratio. As a result A/F ratio excursion can be reduced within 5% when throttle rapidly opens and closes at the various engine conditions.

  • PDF

플러그묘 개체군의 순광합성속도 측정 (Measurement of Net Photosynthetic Rate in the Plug Stand)

  • 김용현;고재풍수
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.311-316
    • /
    • 1997
  • Two methods were used to detrermine the net photosynthetic rate(NPR) in the plug stand using a wind tunnel for plug seedlings Production. One is called as the integration method in which NPR calculated by the use of air current speed and $CO^2$ concentration measured at any heights above the medium surface in a wind tunnel were summed. It was assumed that the air flow at any layer did not mix with the lower or upper air layer. The other is called as the diffusion method in which eddy diffusivities above the plug stand were used to determine the NPR in the plug stand. In this method, $CO^2$ above or inside the plug stand was assumed to be absorbed vertically. NPR determined by the diffusion method was 28~45% of the NPR calculated by the integration method. Considering the magnitude of NPR and the effects of the air current speed on NPR, the integration method would be adequate for the calculation of NPR in the plug stand. Maximum NPR determined using the integration method appeared at the air current speed of 0.7m $s^{-1}$. It was ascribed to the decreased diffusion resistances of $CO^2$ with the increasing air current speed. NPR at the rear region in plug stand was 20~34% lower than that at the front region. NPR sharply decreased with the increase of an elapsed time after the beginning of photoperiod. Therefore $CO^2$ enrichment would be effective to force the growth of plug seedlings in a semi-closed ecological system under artificial lighting.

  • PDF

Numerical Studies of Transient Opposed-Flow Flames using Adaptive Time Integration

  • Im, Hong-Geun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.103-112
    • /
    • 2000
  • Numerical simulations of unsteady opposed-flow flames are performed using an adaptive time integration method designed for differential-algebraic systems. The compressibility effect is considered in deriving the system of equations, such that the numerical difficulties associated with a high-index system are alleviated. The numerical method is implemented for systems with detailed chemical mechanisms and transport properties by utilizing the Chemkin software. Two test simulations are performeds hydrogen/air diffusion flames with an oscillatory strain rate and transient ignition of methane against heated air. Both results show that the rapid transient behavior is successfully captured by the numerical method.

  • PDF