• Title/Summary/Keyword: Air Hygiene

Search Result 411, Processing Time 0.03 seconds

Health Risk Assessment for Workers Exposed to Diazinon Insecticide (디아지논 취급 근로자의 건강 위험성 평가)

  • Jung, Woo Jin;Kim, Chi Nyon;Won, Jong Uk;Kim, Ki Youn;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.100-106
    • /
    • 2012
  • Objectives: Diazinon is an insecticide which acts as a contact stomach and respiratory poison, and used throughout the world to control a wide range of sucking and chewing insects and mites on a range of crops. In this study, the airborne diazinon levels were measured for farmers, pest control operaters, landscapers, and agricultural chemicals sellers, and an assessment of the health risk to the workers was presented. The exposure scenario was based on the route of inhalation and skin absorption. The "OSHA Method No. 62" was used to sample and measure the airborne diazinon levels. The skin wipe method was applied to measure the level of the diazinone exposure through the skin. For the determination of exposure scenario, the exposure factors were surveyed for the daily average inhalation rate and the exposure period and frequency and time of diazinone as well as the body weight and lifetime of the workers. The median values of exposure frequency and exposure time were selected after evaluating the validity of those. Methods: The highest level of the diazinon exposure in the air was $107.21ug/m^3$ in farmers, followed by $93.53ug/m^3$ in landscapers, at $31.40ug/m^3$ in pest control operators, and $1.04ug/m^3$ in agricultural chemical seller. The amount of skin absorption was the highest in farmers at 63.39 ug/day, followed by landscapers at 10.47 ng/day, pest control operaters at 4.26 ng/day, and agricultural chemicals sellers at 0.34 ng/day. The hazardous indices calculated using toxicological reference value were 2.79 for pest control operaters, 0.41 for landscapers, 0.07 for agricultural chemicals sellers, and 0.06 for farmers. Conclusions: While the farmers were exposed to the high levels of diazinon through the air and skin, the pest control operaters, landscapers and agricultural chemicals sellers have more the diazinon hazards than the farmer based on the risk assessment in this study.

Exposure of Outdoor Workers to Particulate Matter in Construction Sites (건설업 옥외작업장 근로자의 미세먼지 노출 실태 조사)

  • Kim, Seung Won;Lee, Ga Hyun;Phee, Young Gyu;Yang, Won-Ho;Ha, Wonchul;Park, Hyunghee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.46-58
    • /
    • 2017
  • Objectives: Particulate matter (PM) at construction sites mostly originates from either construction activities or the atmospheric environment. This study was conducted to evaluate the exposure level to PM and the contribution ratio of atmosphere sources at construction sites. Methods: We reviewed literature and governmental systems related to PM exposure in occupational settings and summarized them. In the field evaluation, five construction sites and one golf course were selected: two from Gyeonggi-do Province and four from North Gyeongsang-do Province. For each site, personal samples from outdoor construction workers and area samples from the outdoor area around the construction site office were collected according to construction work types. PM concentrations reported from nearby National Ambient Air Monitoring Stations were recorded. Respirable dust concentrations, respirable silica concentrations, and several metal concentrations including Cd, Cr, Pb, and As were monitored over four months. In the end we suggested how to manage particulate matter exposure at construction sites. Results: There was little literature reporting on exposure levels of construction workers to PM. Respirable dust concentrations measured in Gyeonggi-do Province were higher than those measured in North Gyeongsang-do Province. The geometric means of respirable dust concentrations in personal samples and area samples were $37.89{\mu}g/m^3$ and $92.86{\mu}g/m^3$, respectively. The respirable dust concentrations were higher than the PM concentrations reported from nearby National Ambient Air Monitoring Station. The geometric means of respirable silica concentrations of personal samples and area samples were $1.3{\mu}g/m^3$ and $1.1{\mu}g/m^3$, respectively. All metal concentrations were lower than 10% of individual Korean occupational exposure limits. Conclusions: Assuming that personal samples consisted of ambient PM and dust originating from work activities and area samples only collected ambient PM, we concluded that the dust exposure of outdoor construction workers originated 40.8% from the atmosphere and 59.2% from construction activities. PM exposure at construction sites should be controlled by employers, as in the case of outdoor heat stress. The Korean government needs to consider setting an occupational exposure limit for respirable dust.

A study on exposure of organic solvents in manufacturing industry (제조업 산업장의 유기용제 노출에 관한 연구)

  • Moon, Deog-Hwan;Kim, Jeong-Ha;Kim, Pil-Ja;Park, Myung-Hee;Hwang, Yong-sik;Lee, Chae-Kwan;Lee, Chang-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.219-228
    • /
    • 2001
  • Objective : For the purpose of preparing the fundamental data and health promotion and control program on organic solvents in air of manufacturing industry. Methods : The author surveyed number of organic solvent components which was used in working site and also determined the organic solvents concentration in air of 927 manufacturing industries and 1,267 working process with gas chromatography(NIOSH manual) for five years from 1995 to 1999. Results : Mean number of solvents components by type of industry, working process was number of 12. There were exceeded to TLV of 1,2-dichloroethane in textile manufacturing industry N,N-dimethyl furan in tanning and dressing of leather ; luggage, handbags, saddlery, harness and footwear manufacturing industry and chemical and chemical product manufacturing industry by type of industry. There were exceeded to TLV of 1,2-dichloroethane in handwriting and drawing process, cellosolve in adhesive spreading process, N,N-dimethly furan in production of solvent process and adhesion process by working process Total exceeded rate to threshold limit values of organic solvents mixture were 12.9% for EI(Exposure index) and 10.0% for Em(Estimation of mixture) by type of industry, 11.3% for EI and 8.2% for Em by type of working process. The highest exceed rate was 36.7% for EI in tanning and dressing of leather ; luggage handbags, saddlery, harness and footwear manufacturing industry and 29.0% for Em in textile manufacturing industry. The highest exceeded rate was 23.1% for EI and 12.5% for Em in adhesive spreading process by working process. Mean values of total subjects by type of industry and type of working process were $0.7{\pm}1.8$ for EI and $0.7{\pm}1.7$ for Em respectively. Conclusions : As above results, the author suggest that it makes the environmental control program on 1.2-dichloroethane, N,N-dimethyl furan, cellosolve by kind of organic solvent and on textile manufacturing industry, tanning and dressing of leather ; luggage, handbags, saddlery harness and footwear manufacturing industry by type of industry, and on handwriting, drawing process and adhesive spreading process and adhesion process by type of working process.

  • PDF

Guidelines for dental clinic infection prevention during COVID-19 pandemic (코로나 바이러스 대유행에 따른 치과 의료 관리 가이드라인)

  • Kim, Jin
    • Journal of Korean Academy of Dental Administration
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Dental settings have unique characteristics that warrant specific infection control considerations, including (1) prioritizing the most critical dental services and provide care in a way that minimizes harm to patients due to delayed care, or harm to personnel from potential exposure to persons infected with the COVID-19 disease, and (2) proactively communicate to both personnel and patients the need for them to stay at home if sick. For health care, an interim infection prevention and control recommendation (COVID-19) is recommended for patients suspected of having coronavirus or those whose status has been confirmed. SARS-CoV-2, which is the virus that causes COVID-19, is thought to be spread primarily between people who are in close contact with one another (within 6 feet) through respiratory droplets that are produced when an infected person coughs, sneezes, or talks. Airborne transmission from person-to-person over long distances is unlikely. However, COVID-19 is a new disease, and there remain uncertainties about its mode of spreads and the severity of illness it causes. The virus has been shown to persist in aerosols for several hours, and on some surfaces for days under laboratory conditions. COVID-19 may also be spread by people who are asymptomatic. The practice of dentistry involves the use of rotary dental and surgical instruments, such as handpieces or ultrasonic scalers, and air-water syringes. These instruments create a visible spray that can contain particle droplets of water, saliva, blood, microorganisms, and other debris. While KF 94 masks protect the mucous membranes of the mouth and nose from droplet spatter, they do not provide complete protection against the inhalation of airborne infectious agents. If the patient is afebrile (temperature <100.4°F)* and otherwise without symptoms consistent with COVID-19, then dental care may be provided using appropriate engineering and administrative controls, work practices, and infection control considerations. It is necessary to provide supplies for respiratory hygiene and cough etiquette, including alcohol-based hand rub (ABHR) with 60%~95% alcohol, tissues, and no-touch receptacles for disposal, at healthcare facility entrances, waiting rooms, and patient check-ins. There is also the need to install physical barriers (e.g., glass or plastic windows) in reception areas to limit close contact between triage personnel and potentially infectious patients. Ideally, dental treatment should be provided in individual rooms whenever possible, with a spacing of at least 6 feet between the patient chairs. Further, the use of easy-to-clean floor-to-ceiling barriers will enhance the effectiveness of portable HEPA air filtration systems. Before and after all patient contact, contact with potentially infectious material, and before putting on and after removing personal protective equipment, including gloves, hand hygiene after removal is particularly important to remove any pathogens that may have been transferred to the bare hands during the removal process. ABHR with 60~95% alcohol is to be used, or hands should be washed with soap and water for at least 20 s.

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

The Variation of Indoor Air Quality in Nursing Home

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.1
    • /
    • pp.117-124
    • /
    • 2020
  • In this paper, we proposed a plan to maintain comfortable indoor air quality in nursing homes by suggesting ways to reduce items temporarily exceeding the reference values through real-time concentration variation analysis of indoor air quality. Five items including PM10, CO2, CO, VOC, and Radon are measured at nursing homes in spring (April) and autumn (September) was carried out and all of the measured items were analyzed to satisfy the criteria set by the Indoor Air Quality Control Act. As a result of the analysis of the real-time concentration change, the concentration of CO2 was close to the reference value based on the number of occupants in the sick room. Due to the disinfectant (alcohol) used to disinfect and the auxiliary tools (adhesive) used in the operation of the program such as making and coloring, it was analyzed to temporarily exceed the standard value in the hall. In conclusion, it is possible to provide pleasant indoor air quality and contribute to securing the nursing home's competitiveness if periodic ventilation, natural disinfectant and eco-friendly product are used in consideration of the thermal environment.

Characteristics of Exposure Distribution to Hazard Factors in Indoor Swimming Pool Activity Areas in Gwangju (수영장 활동공간 내 유해인자 노출특성 연구)

  • Lee, Youn-Goog;Kim, Nan-Hee;Choi, Young-Seop;Kim, Sun-Jung;Park, Ju-Hyun;Kang, Yu-Mi;Bae, Seok-Jin;Seo, Kye-Won;Kim, Jong-Min
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Objective: This study is designed to measure the concentration of DBPs (disinfection by-products) in pool water and in air and to estimate the carcinogenic potential through the evaluation of inhalation exposure. Methods: The subjects were six indoor swimming pools with many users in Gwangju. Samples of pool water and indoor air were taken every one month from August 2018 to August 2019 and analyzed for eight swimming pool standards. Three-liter air samples were collected and the VOCs were analyzed using GC/MS directly connected to thermal desorption. Results: pH was 6.8-7.5 and the concentration of free residual chlorine in pool water was 0.40-0.96 ?/ℓ. Physicochemical test items such as KMnO4 consumption and heavy metal items such as Aluminum met existing pool hygiene standards. No VOC materials were detected except for the DBPs. The concentration of THMs in the pool water was 11.05-41.77 ㎍/L and the THMs mainly consist of Chloroform (63-97%) and BDCM (3-31%). The concentration of indoor air THMs is 13.24-32.48 ㎍/㎥ and consists of Chloroform. The results of carcinogenic assessment of chloroform in the indoor swimming pool via inhalation exposure were 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA. Conclusions: The concentration of THMs in the pool water is 11.05-41.77 ㎍/L, most of which is chloroform. In addition, the concentration of indoor air THMs is 13.24-32.48 ㎍/㎥. The result of carcinogenic assessment of chloroform was 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA.

A Factor Analysis on Job Stress Level in Dental Hygienists (치과위생사의 직무스트레스에 관한 분석요인)

  • Kim, Jee-Hwa;Oh, Na-Rae;Jeong, Mi-Ae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1220-1228
    • /
    • 2012
  • This study was carried out in order to offer medical service in good quality by enhancing dental hygienists' job satisfaction and to arrange basic data necessary for individual development and health promotion in dental hygienists through grasping the job stress level and job satisfaction of being experienced by dental hygienists, and the correlation. The self-administered questionnaire was surveyed and collected from August 1-12 of 2011 targeting 210 dental hygienists of general hospitals, dental hospitals, and dental clinics nationwide(Seoul, Gyeonggi, Daegu, Pohang).The analysis was made on 205 people. The collected data was analyzed by using SPSS WIN 15.0 program. As a result, out of job stress, the average was indicated to be the highest with 2.71 in 'job demand.' As a result of examining about sphere-based relationship between health perception level and job stress related to building in dental hygienists, the central nervous system manifestation showed statistically significant positive correlation with physical environment(r=.281, p<.001), job demand(r=.281, p<.001), relational conflict(r=.163, p<.05), organizational system(r=.166, p<.05), compensation inappropriateness(r=.267, p<.001), and job stress(r=.311, p<.001). Overall, the building-related health perception level showed statistically significant correlation with physical environment(r=.259, p<.001), job demand(r=.311, p<.001), relational conflict(r=.172, p<.05), organizational system(r=.158, p<.05), compensation inappropriateness(r=.197, p<.01), and job stress(r=.275, p<.001). They need to improve their quality of life and life and mental health by developing proper air conditioning system and using one in their work place. if so, they could contribute to better quality of oral cavity service for everyone.

A Study of Summer Socks on Their Properties of Hygiene and Comfortableness (여름양말의 위생성과 쾌적성에 관한 연구)

  • 정희근;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.1
    • /
    • pp.98-112
    • /
    • 1996
  • Tho purpose of this study was to investigate hygienic and comfortable properties of socks. Materials are nine summer socks either frequently being worn or new products recently introduced to market. Three female and three male adults participated in this study. Through wearing experiment, the numbers of microbes on foot and sock were counted and subjective sensation was measured. The microbes were isolated and identified based on growth physiological characteristics. Nine different socks had smaller number of bacteria of sock than that of foot. The number of bacteria of sock was significantly related with that of foot in cotton socks, in piled cotton socks, in mesh cotton socks, in cotton+ nylon+ linen blended socks, in nylon socks. Total number of bacteria of tv cut finished socks was most small and total number of bacteria was increased in the order of ultra fresh finished socks, untreated cotton socks, nylon socks, cotton + nylon+ linen blended socks, mesh cotton socks, polyester+ nylcn+ linen blended socks, piled cotton socks, cotton socks. Total number of bacteria of cotton socks and piled cotton socks were significantly different from that of uv cut finished socks. Finished socks and .jocks has high air permeability had significantly small number of bacteria. Comfortable sensation in nylon socks and polyester+nylon+linen socks was significantly uncomfortable. The way socks finished and air permeability of .jocks affected theirs hygienic property, while fiber type of them affected comfortablene, is. Bacteria identified were Staphylo coccus aureus, S. au rice larir, S. cahn ii, S. ep ids midis, S. haemo Iyticus, S. h am in 2's. S.fapraphyticus, S. warnery, 1 cinetobater calcoaceticus bio. anitratus, p.reudomonas mendocina, p. paucimobilis, Flavimonas Q ryzihabitans (CDC Group VE-2), and Xanthomanas maltophina. Fungi isolated were Spicaria sp., Thrichoderma sp., Fusarium sp., Aspergillus sp., Epicoccum sp., Cladosporium sp., and Penicillium sp..

  • PDF

Causal Analysis of Education Function Space Parameters of University Dormitory (대학기숙사 교육기능공간의 매개변수를 통한 인과분석)

  • Park, Hang-Ja;Park, Sung-Jin;No, Young-Ran
    • Journal of the Korean housing association
    • /
    • v.21 no.4
    • /
    • pp.23-31
    • /
    • 2010
  • This study aims to examine the educational function space of university dormitories at local universities with corridor centered structure in Honam area regions based on direct and indirect parameters on the whole satisfaction of users in residential environment factors and personal characteristics. First, according to relations among parameters, educational and cultural activities of four major activities within the dormitory had indirect influences on social activities, eating and sleeping activities had no direct influence on other activities. And social activity had direct influence on the general satisfaction as an important parameter and educational and cultural activities had indirect influence on the whole satisfaction through social activities. Detailed results show that, in the first educational activities directly affecting the lighting and air conditioning facilities (0.22), safety (0.326), Territoriality (0.327), the space density (-0.167), directions (-0.166) and yeohyang having personal characteristics and the safety of the second cultural activities (0.183), Territoriality (0.361), Aesthetics (-0.13) and the personal characteristics Sex (-0.179), the direct effect, third, and erosion has a direct impact on activity The flexibility of the space factor (-0.128) and Territoriality (0.38) and the personal characteristics grade (0.172), respectively. Fourth in social activities directly affecting the pathfinding (-0.104), and parameter, education (0.388) and cultural activities (0.445), and some of the factors affecting the indirect lighting and air conditioning facilities, safety, and Territoriality, the space density, directions, grade, they could influence through educational activities to be analyzed. That is, territoriality in educational function space is the important factor that users react very sensitively in educational, eating and sleeping activities and educational function space must secure area and division considering personal and public use as the space accommodating activity which is lacking in unit residential space. Accordingly, the safety of educational function space in university dormitory is considered as the fundamental safety matter on the fire prevention, hygiene and cleanness for users in the satisfaction of educational and cultural activities.