• Title/Summary/Keyword: Air Heater

Search Result 485, Processing Time 0.025 seconds

Building Energy Management System Coupling with Renewable Energy System

  • Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.34 no.9
    • /
    • pp.705-709
    • /
    • 2010
  • Buildings nowadays are increasingly expected to need higher and more economic performance requirements. Energy consumption in buildings accounts for over 30% of total energy use. The Building Energy Management System (BEMS) and renewable energy (RE) technologies are considered as a potential measure to improve energy efficiency and reduce use of grid-power. It is, however, a challenge to utilise the intermittent energy supply of RE in building energy systems. This paper presents an experimental study on a RE-embedded BEMS. A control algorithm for the RE-embedded BEMS was designed to maximise the utilisation of RE and eventually to reduce electrical utility bill. The proposed system is tested at a laboratorial chamber with an air conditioner, fan and heater. The contribution of RE in building energy system is discussed to this end.

Effects of Cokes Air Heater on Energy Saving in Horticultural Greenhouse (코크스 난방기를 활용한 시설원예 난방비 절감 효과)

  • Kim, Hyun-Hwan;Jeon, Hee;Lee, Si-Young;Kim, Jin-Young
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.04a
    • /
    • pp.115-119
    • /
    • 2002
  • 석유를 이용한 시설원예 난방이 90%를 넘고 있으며, 최근 유가의 불안정으로 시설원예 난방비 비중이 30%를 이상을 차지하고 있어 대체에너지를 이용한 난방비 절감기술이 절실하다. 현재 시설원예 면적은 약 52,189ha(채소, 화훼포함)이며, 이중 난방면적은 13,621ha로 전체 면적의 26%가 난발비의 부담을 안고 시설재배를 하고 있다. 이에 단위 열량당 연료비가 비교적 저렴한 코크스를 이용하는 난방기 중 온풍기를 개발하여 시설원예 난방비를 절감코자 본 연구를 수행하였다. (중략)

  • PDF

An Internet-based Survey on the Characteristics of Energy Consumption of Apartment (인터넷을 이용한 공동주택의 에너지소비특성 실태조사)

  • 황광일
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.41-48
    • /
    • 2002
  • The purpose of this study is, by the method of the internet-based survey, to understand the relations between the residential condition and the characteristics of energy consumption. The followings are the results of this study. $\circled1$ Among 601 responses, evaluable 329s means that the user fully understanding what this survey is for. $\circled2$ Gas-or oil-burners occupy 80% of heater. $\circled3$ Contrary to expectations, we can not find out the relations between the cooling area and the cooling capacity of Air-conditioners. $\circled4$ There is no relation between the direction of apartment and the cooling capacity, neither. $\circled5$ During the summer, average and maximum monthly electric fare for cooling is ₩198/$\textrm{m}^2$ and ₩461/$\textrm{m}^2$, respectively. $\circled6$ And during the winter, average and maximum monthly electric fare for heating is ₩335/$\textrm{m}^2$ and ₩484/$\textrm{m}^2$, respectively.

An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

A CMOS Compatible Micromachined Microwave Power Sensor (CMOS 공정과 호환되는 마이크로머시닝 기술을 이용한 마이크로파 전력센서)

  • 이대성;이경일;황학인;이원호;전형우;김왕섭
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.439-442
    • /
    • 2002
  • We present in this Paper a microwave Power sensor fabricated by a standard CMOS process and a bulk micromachining process. The sensor consists of a CPW transmission line, a resistor as a healer, and thermocouple arrays. An input microwave heater, the resistor so that the temperature rises proportionally to the microwave power and tile thermocouple arrays convert it to an electrical signal. The sensor uses air bridged 8round of CPW realized by wire bonding to reduce tile device size and cost and to improve the thermal impedance. Al/poly-Si junctions are used for the thermocouples. Poly-Si is used for tile resister and Aluminium is for transmission line. The resistor and hot junctions of the thermocouples are placed on a low stress silicon nitride diaphragm to minimize a thermal loss. The fabricated device operates properly from 1㎼ to 100㎽\ulcorner of input power. The sensitivity was measured to be ,3.2~4.7 V/W.

  • PDF

An Investigation on the Heat Efficiency of Hot Air Heater (온풍난방기 열효율조사 연구)

  • Kim, Yeong-Jung;Yu, Yeong-Seon;Gang, Geum-Chun;Baek, Lee;Yun, Jin-Ha
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.133-138
    • /
    • 2002
  • 온풍난방기 20대를 대상으로 온풍난방기의 베기가스중 탄산가스농도, 온풍온도차, 배기가스온도 및 열효율을 조사하여 사용연수별로 분석하였으며 주요 결과는 다음과 같다. 가. 사용연수별 온풍난방기 배기가스중 탄산가스농도와 온풍온도차는 사용연수에 따른 조사표본의 부족으로 큰 차이가 있었다고 하기는 어렵고 정확한 조사를 위해서는 보다 많은 대수가 필요할 것으로 판단된다. 나. 사용연수별 배기가스온도는 사용연한이 오래될수록 높아졌다고 판단된다. 이는 열교환기에서 흡입공기와 연소열이 열교환이 충분히 이루어지지 않았거나, 버너노즐의 노후화, 버너송풍기, 온풍난방기 송풍기의 노후화에 따른 결과라 여겨진다. 사용연수에 따른 배기가스온도는 회귀방정식 Y= 79.032Ln(X) + 116.66 ($R^2$= 0.6784)로 나타낼 수 있었다. 다. 사용연수별 온풍난방기의 열효율은 사용연한이 오래될수록 감소하는 경향을 보였으며 회귀방정식 Y = 95.167 X $^{-0.054}$ ($R^2$= 0.5696)로 나타낼 수 있었다.

  • PDF

Economic analysis of Electric heating appliances (전기난방기구의 경제성 분석 비교)

  • Kim, Yong-Ha;Lee, Kwang-Sung;Nam, Kim-Hyun;Park, Nam-Chul;Woo, Sung-Min;Kim, Mi-Ye;Lim, Hyun-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.448-452
    • /
    • 2006
  • Many kinds of electric heating appliance is used by user interface and desire. Far infrared ray heating system can use a kind of main heating appliance. This paper gives un saving amounts, energy curtailment money and payback period between far infrared ray heating system and existing electric heating appliance - EHP, electric air heater, electric radiator, electric floor heating system - from economy analysis.

  • PDF

Development of Control Software for KOREA Standard EMU (도시철도차량용 국내 표준모델의 주제어 S/W개발(2))

  • 안태기;한성호;백종현;이수길;박현준
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.302-309
    • /
    • 1999
  • This paper is intended to provide a method to design control software fur the TCMS, train control and monitoring system. The TCMS with this control software will be applied KOREA Standard EMU. The control software is designed by SCADE Case tool to concern safety and reliability. The function for the EMU is implemented in software easily programmed, using a functional block, graphic programming language. the control software has modular design and each module is tested with SCADE simulator. This time we focus a HVAC(heater, ventilation and air conditioner controller) control module, present a design method and a simulation method for that module.

  • PDF

Design of type 316L stainless steel 700 ℃ high-temperature piping

  • Hyeong-Yeon Lee;Hyeonil Kim;Jaehyuk Eoh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3581-3590
    • /
    • 2023
  • High-temperature design evaluations were conducted on Type 316L stainless steel piping for a 700 ℃ large-capacity thermal energy storage verification test loop (TESET) under construction at KAERI. The hot leg piping with sodium coolant at 700 ℃ connects the main components of the loop heater, hot storage tank, and air-to-sodium heat exchanger. Currently, the design rules of ASME B31.1 and RCC-MRx provide design procedures for high-temperature piping in the creep range for Type 316L stainless steel. However, the design material properties around 700 ℃ are not available in those rules. Therefore, a number of material tests, including creep tests at various temperatures, were conducted to determine the insufficient material properties and relevant design coefficients so that high-temperature design on the 700 ℃ piping may be possible. It was shown that Type 316L stainless steel can be used in a 700 ℃ high-temperature piping system of Generation IV reactor systems or a renewable energy systems, such as thermal energy storage systems, for a limited operation time.