• 제목/요약/키워드: Air Flow Computer Simulation

검색결과 106건 처리시간 0.032초

수중발사를 위한 ATP 방식 압축수 방출시스템의 동특성 해석 (Analysis of the Dynamic Characteristics of Pressurized Water Discharging System for Underwater Launch using ATP)

  • 한명철;김정관;김광수
    • 제어로봇시스템학회논문지
    • /
    • 제15권6호
    • /
    • pp.567-572
    • /
    • 2009
  • The underwater launch system using an ATP consists of five parts: compressor tank, proportional flow control servo valve, expulsion spool valve, air turbine pump, and discharge tube. The purpose of this study is to develop an underwater launch system using an ATP and to verify the validity of the system. The proportional flow control servo valve is modeled as a 2nd order transfer function. The projectile is ejected by pressurized water through the air turbine pump, which is controlled by expulsion valve. The mathematical model is derived to estimate the dynamic characteristics of the system, and the important design parameters are derived by using simulations. The computer simulation results show the dynamic characteristics and the possibility of control for underwater launch system.

압축기출구에 공기분사가 터보과급 디젤기관의 성능에 미치는 영향에 관한 연구 (A Study on the Effects of Injected Air into the Compressor Exit for the Performances of a Turbocharged Diesel Engine)

  • 최낙정;이창식
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.796-805
    • /
    • 1995
  • For the purpose of improving performances of a turbocharged diesel engine at low speed, this study investigates the effects of the injected air for the performances and flow characteristics in the intake and exhaust pipes by using the computer simulation with test bed. In the theoretical analysis, the whole flow system, including engine cylinders and intake and exhaust pipes, is calculated numerically by the method of filling and emptying. From the results of this study, the following conclusions may be summarized. Increasing injected air pressure into the pipe of compressor exit brings about the improvement in a performance and flow characteristics of intake and exhaust pipes under full load operating conditions at 1000 rpm of the engine speed, but shows trends of the inferior performances under no load operating conditions at 2000 rpm of the engine speed.

수치해석에 의한 고압다이캐스팅용 금형설계 및 주조공정해석 (Analysis of the High Pressure Die Casting Process by Computer Simulation)

  • 이창호;최재권;남태운
    • 한국주조공학회지
    • /
    • 제20권6호
    • /
    • pp.400-406
    • /
    • 2000
  • Computer simulation for the predictions of casting defects is very important to produce high quality castings with less cost. Complicate shaped Al solenoid housing part was selected to be cold chamber die cast and a numerical simulation technique was applied for the optimization of the chill vent position and gating. A first design led to insufficient central flow. This flow left the last filled areas falling into the inner portion of the part. And last filled area did not fit the chill vent position. So these resulted in a high possibility of air entrapment in the casting and the design was not proper for the part. The design was improved by using a proper gating system, a more chill vent and proper overflow positions. New design provided a homogenous mold filling pattern and the last filled areas that being located at the overflow and chill vent. Casting plan which produce good quality solenoid housing part was established by using the computer simulation.

  • PDF

종류식 터널내 소요 환기량에 의한 터널환기 및 화재 시뮬레이션 연구 ( 임고 4 터널 ) (Fire Simulation Study and Tunnel Ventilation of Requirement in the Longitudinal Tunnel. (In Yimgo-4th Tunnel))

  • 채경희
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1378-1385
    • /
    • 2008
  • This study is aimed to analyze the flow patterns and thermal characteristics by computer simulation under the variations of fire strength for Daegu-Pahang Yimgo-4th tunnel, from which flow and heat distributions are predicted in the longitudinal tunnel. Though the results of numerical computations, followings are found; one is that the volume flow rate is discontinuously increasing as closer to fire location, and the other is that a critical design to get faster flow rate is required because of existence of backlayer flow for the high fire strength in view of safety for the people in fire of the tunnel.

  • PDF

종류식 터널내에서 화재에 의한 열 및 기류분포 예측에 관한 연구 (A Study of Thermal and Air Distribution Forcast by Firing in the Longitudinal Tunnel (In Yimgo - 4th Tunnel))

  • 채경희
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1209-1212
    • /
    • 2006
  • This study is aimed to analyze the floe patterns and thermal characteristics by computer simulation under the variations of fire strength for Daegu-Pahang Yimgo-4th tunnel, from which flow and heat distributions are predicted In the longitudinal tunnel. Though the results of numerical computations, followings are found; one is that the volume flow rate is discontinuously increasing as closer to fire location, and the other is that a critical design to get faster flow rate is required because of existence of backlayer flow for the high fire strength in view of safety for the people in fire of the tunnel.

  • PDF

차량용 열제어 관리 시스템의 성능 시뮬레이션 프로그램 개발 (Development of Simulation Program of Vehicle Thermal Managements System)

  • 배석정;허형석;김현철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.345-348
    • /
    • 2008
  • The computer-aided performance simulation can reduce periods for development of products and cut down on the cost comparing with former trial-and-error procedures. This study has developed a simulation program for a vehicle thermal management system integrating an engine cooling system and an air conditioning system considering interactions and arrangement of air side heat exchangers such as power steering oil cooler, air-cooled transmission oil cooler, condenser, and radiator. The program may be also used for the system performance analysis according to the configuration of the engine coolant side heat exchangers such as water-cooled transmission oil cooler, EGR cooler, and heater core. Experiments utilizing an environmental wind tunnel has been conducted to assess the performance of the system according to the arrangement of air side heat exchangers. Some modification of the coolant loop layout can enhance the heat core performance up to 7% according to the results of the simulations.

  • PDF

용융탄산염 연료 전지 스택의 성능 및 열전달 해석 (An Analysis on the Performance and the Heat Transfer of Molten Carbonate Fuel Cell Stack)

  • 구자용;서종철;김유
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.120-129
    • /
    • 1994
  • A numerical investigation has been carried out for the electrochemical reaction, mass and heat transfer characteristics of the Molten Carbonate Fuel Cell(MCFC) stack. The effects of cooling air channel and water gas shift reaction were taken into account. The current density distribution of electrodes, the molecular fractions of reactant gasses and three dimensional temperature distribution can be calculated and shown by several lines of equivalent values. The results have been compared with the existing ones, and reasonable agreement has been obtained. To examine the influence of changing parameters, such as the composition of reactant gases, the target average current density, the utilization of reactant gases, the cooling air inlet temperature and flow rates, the computer simulation has been done. The analysis method and computer program developed in this study will be greatly helpful to design and verify the optimum operating condition of MCFC stack.

  • PDF

대형 강의실의 실내 열환경 실측 및 컴퓨터시뮬레이션 비교 연구 (Field Measurements and CFD Simulations of Indoor Thermal Environments in the Assembly Hall)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.179-186
    • /
    • 2004
  • The evaluation of the indoor environment of the Assembly Hall in the University, which is designed to be a large space, requires efficient design of its heating system that takes into consideration natural convection and the characteristics of the occupant's spaces. Indoor thermal environment was measured in the field and simulated with CFD code. The estimations of temperature distribution and indoor airflow distribution must be carried out simultaneously, as the thermal stratification is induced by natural convection flows. In order to simulate the even distribution of factors affecting the indoor environment, including temperature and airflow, Phoenics is used. The turbulent flow model adopted is the RNG k- model. The inlets and outlets of the air-conditioning systems, material and thermal properties, and the size of the test room ($35m{\times}18m{\times}10m$) are used for the simulation. Since the Assembly Hall is symmetric, half of the space is simulated. A Cartesian grid is used for calculation and the number of grids are respectively $60{\times}45{\times}35$. The results of the computer simulation during winter conditions are compared with the measurements at the typical points in the assembly hall with the heating system. After evaluating the results of the computer simulations, the methods of the heating system and layout are suggested.

바닥복사 난방시스템의 에너지 유동특성에 관한 시뮬레이션 및 실험적 연구 (Simulation and Experimental Study for Energy Flow Dynamics of Floor Radiant Heating System)

  • 안병천;송재엽;이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.927-932
    • /
    • 2006
  • A simulation and experimental study for energy flow dynamics of floor radiant heating system were performed. The study was done under both environmental chamber and a house with several rooms. The unsteady energy analysis method using equivalent R-C circuit and radiation heat transfer analysis of enclosure analysis method with simple structured rooms were used for computer simulation. Also, first order dynamics with time delay in analyzing the return water was considered. The results of temperature changes of the simulation study are good fit with the ones of experimental one.

  • PDF

MAGMAsoft를 이용한 자동차 변속기용 Gear Housing의 다이캐스팅 주조공정 설계 (Die Casting Process Design for Gear Housing of Automobile Transmission by Using MAGMAsoft)

  • 김억수
    • 소성∙가공
    • /
    • 제14권2호
    • /
    • pp.112-120
    • /
    • 2005
  • In the die casting process, the flow of liquid metal has significant influence on the quality of casting products and die life. For the optimal process design of gear housing of automobile transmission, various analyses were performed in this study by using computer simulation code, MAGMAsoft. The simulation has been focused on the molten metal behaviors during the mold filling and solidification stages for the sound casting products. Also internal defects were predicted by application of air pressure and feeding criteria.