Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF

Design Of Air-Distribution System in a Duct (취출구를 가진 덕트의 공기분배장치 설계)

  • Kang, Hyung-Seon;Cho, Byung-Ki;Koh, Young-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.954-960
    • /
    • 2007
  • The purpose of this paper is to obtain design method of air-distribution system. Air-distribution system is composed of blower, duct, diffusers and measuring equipment. The air-flow rate from each diffuser is not equal. The air-flow rate is calculated with the combined equations which are Bernoulli's equation, continuity equation and minor loss equations. Inlet condition and outlet condition are adapted in each duct system. Then square difference between function of maximum air-flow rate and minimum air-flow rate is used as an object function. Area of diffuser and velocity are established as constraints. To minimize the object function, the optimization method is used. After optimization the design variables are selected under satisfaction of constraints. The air-distribution system is calculated again with the result of optimized design variable. It is shown that the air-distribution system has the equal air-flow rate from diffusers.

Air Flow Analysis due to the Configuration of Car Body Radiator Grill (차체 라디에이터그릴의 형상에 따른 공기 유동해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.3
    • /
    • pp.21-27
    • /
    • 2013
  • This study is investigated on flow analysis according to grill configuration of radiator. The stream of flow which pass through radiator grill in car body and the contour of pressure distribution are estimated by the basis. As the magnitude of resistance force which flow affects the car body is investigated so that the power reduction can be reduced. As the pressure inside radiator grill is assessed, more efficiency can be investigated in order that the flow rate inside car body can be increased. Model 2 has the most air resistance and model 1 has the least among model 1, 2 and 3. Model 1 has the most air flow rate at inside. There are model 3 and 2 simulated according to flow rate. As the curved surface at radiator grill configuration increases in number, air flow rate becomes distributed uniformly. By considering the effect on air resistance and air flow rate at radiator grill, model 3 becomes the most effective configuration.

A Convergence Study through Flow Analysis due to the Configuration of Automotive Air Breather (자동차 에어 브리더의 형상에 따른 유동해석을 통한 융합연구)

  • Oh, Bum Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.10
    • /
    • pp.265-270
    • /
    • 2018
  • In this study, the flow analysis due to the car body configuration of air breather was carried out. As the resistance force whose flow affects car body has been studied, it is published that the electricity can be decreased. When the inner pressure of air breather is evaluated, there is the study of efficiency in order to raise the flow rate of inner body. At a total of five models, it is shown that the air resistance and pressure happen differently and the air pressure of side flow is changed. This study result was analyzed by using the analysis program of ANSYS, a study model was modelled using the CATIA V5 modelling program. It was investigated that the air flow rate was distributed uniformly as the curved surface of air breather configuration increases. It is thought as the most effective design method to design the air breather by considering the effect on the air resistance and flow. Also, through the design of the vehicle's airbrid configuration, the design of the product can incorporate a aesthetic sense into the design.

A/F Control of an MPI Engine on Transient Conditions with an Intergration type Ultrasonic Flow Meter (적분형 초음파 유량계를 이용한 MPI 엔진의 비정상상태 공연비 제어)

  • 김중일;장준석;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.36-47
    • /
    • 1999
  • Three-way catalyst converter, cleaning up the exhaust gas contamination of SI engine, has the best efficiency when A/F ratio is near the stoichiometry . The feedback control using oxygen sensors in the exhaust manifold has limits caused by the system delays. So the accurate measurement of air flow rate to an engine is essential to control the fuel injection rate especially on transient condition like the rapid throttle opening and closing. To measure the rapid change of flow rates. the air flow meter for the engine requires quick response, flow reversal detection, and linearity . Tjhe proposed integration type air flow meter (IFM), composed of an ultrasonic flow meter with an integration circuit, has significantly improved the measurement accuracy of air mass inducted through the throttle body. The proposed control method estimated the air mass at the cylinder port using the measured air mass at the throttle . For the fuel dynamic model, the two constant fuel model is introduced . The control parameters from air and fuel dynamics are tuned to minimize the excursion of the air fuel ratio. As a result A/F ratio excursion can be reduced within 5% when throttle rapidly opens and closes at the various engine conditions.

  • PDF

A Study on the Turbulent Flow Characteristics of Swirl Jets for Improvement of Combustion Efficiency (연소효율 개선을 위한 스월제트의 난류유동 특성에 관한 연구)

  • Ko, Dong Guk;Yoon, Suck Ju
    • Journal of ILASS-Korea
    • /
    • v.19 no.2
    • /
    • pp.75-81
    • /
    • 2014
  • Swirl flow in the gun type burner has a decisive effect on the stabilization of the flame, improvement of the combustion efficiency, and also a reduction of NOx. This swirl flow is created by the spinner which is inside the airtube that guide the combustion air. Gun type burner has generally the inner devices composed nozzle adapter, spark gap ignitor, and spinner. These inner components change the air flow behavior passing through air tube. Meanwhile, turbulent characteristics of this air flow are important to understand the combustion phenomena in the gun type burner, because the mixture of fuel and air are depended on. However, nearly all of the studies have been analyzed the turbulent flow of simplified combustion formation without the inner devices. So, this study conducted the measurement using by hot-wire anemometer and analyzed turbulent flow characteristics of the swirl flow discharged from the air tube with inner devices. Turbulence characteristics come up in this study were turbulence intensity, kinetic energy and shear stress of the air flow with the change of the distance of axial direction from the exit of the air tube.

Heat Transfer Performance Variation of Condenser due to Non-uniform Air Flow (불균일한 풍속분포에 따른 응축기의 열전달 성능 변화)

  • Lee, Won-Jong;Jeong, Ji Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • Heat transfer performance variation of a condenser caused by non-uniform distribution of air flow was investigated using a numerical simulation method. A heat exchanger used for a outdoor unit of a commercial heat pump system and represented by a numerical model was selected. Non-uniform profile of air-velocity was constructed by measuring the air velocity at various locations of the outdoor unit. Simulation was conducted for various refrigerant circuits and air flow conditions. Simulation results show that the heat transfer capacity was reduced depending on the air-flow rate and the refrigerant circuit configuration. It is also shown that the capacity reduction rate is increased as the average air velocity decreases.

Numerical study on the flow characteristics in Air-conditioner duct of EMU (전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구)

  • Kim Seung-Tech;Kim Sung-Jong;Park Geun-Soo;Park Hyung-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

Plotting of 13 Kinds of Properties on Temperature-Entropy Chart of Air (공기의 온도-엔트로피 선도 상에서 13 종류의 물성치 작도)

  • Kim, Deok-Jin;Kim, Duck-Bong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1191-1196
    • /
    • 2009
  • The T-s chart of air displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. In previous study, the software analyzing 31 kinds of values in water system and 32 kinds of values in air-conditioning system were developed. In this study, the software drawing 13 kinds of quantity of state on air properties as ideal gas and analyzing 25 kinds of values in any air system was developed. The 13 kinds of quantity of state on air properties are temperature, pressure, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, and velocity of sound, and the 25 kinds of values including 13 kinds are mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, reversible work, lost work, and relative humidity. The developed software can draw any range of chart and analysis any state or process on air system. Also, this supports various document-editing functions such as power point. We wish to this chart is a help to design, analysis, and education in air system field.

  • PDF

Development of an external twin-fluid nozzle for Selective Catalytic Reduction (선택적 촉매 환원법을 위한 외부 혼합형 이유체 노즐 개발에 대한 실험적 연구)

  • Park, J.K.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.24-33
    • /
    • 2004
  • The effect of the working fluid flow conditions and nozzle geometry on the spray performance of a twin-fluid nozzle used in Selective Catalytic Reduction is investigated experimentally. The liquid pressure is varied in the range of 0.3atm to 1.5atm and the air pressure is varied from the 0.5atm to 3.0atm. relative position between liquid nozzle(internal nozzle) and air nozzle(external nozzle) tip changes front 1mm inside the air nozzle to 1mm outside the air nozzle. The orifice diameter of the air nozzle is varied with 5mm. 6mm and 7mm. Spray visualization is realized with CCD-Camera. SMD(Sauter Mean Diameter) and mean particle velocities are measured by PDPA(Phase Doppler Particle Analyzer) under various experimental conditions. The measuring point is 300mm away from the nozzle tip in the downstream spray. The experimental results are that spray angle is depended air flow rate because nozzle diameter, air pressure and nozzle tip relative positions are related air flow rate. SMD is depended air flow rate and water flow rate. Also, SMD is increased when water flow rate is bigger. SMD is decreased when Air flow rate is bigger.

  • PDF