• Title/Summary/Keyword: Air Data Calibration

Search Result 72, Processing Time 0.029 seconds

A Study on subtitle synchronization calibration to enhance hearing-impaired persons' viewing convenience of e-sports contents or game streamer contents (청각장애인의 이스포츠 중계방송 및 게임 스트리머 콘텐츠 시청 편의성 증대를 위한 자막 동기화 보정 연구)

  • Shin, Dong-Hwan;Kim, Jeong-Soo;Kim, Chang-Won
    • Journal of Korea Game Society
    • /
    • v.19 no.1
    • /
    • pp.73-84
    • /
    • 2019
  • This study is intended to suggest ways to improve the quality of the service of subtitles provided for the convenience of viewing for deaf people on e-sports broadcast content and game streamer content. Generally, subtitling files of broadcast content are manually written on air by stenographers, so a delay of 3 to 5 seconds is inevitable compared to the original content. Therefore, the present study proposed the formation of an automatic synchronization calibration system using speech recognition technology. In addition, a content application experiment using this system was conducted, and the final result confirmed that the time of synchronization error of subtitling data could be reduced to less than 1 second.

The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings (외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포)

  • Park, Ju-Hyun;Yoon, sung-min;Song, Du-Sam;Kim, Yong-Sik
    • Journal of Urban Science
    • /
    • v.8 no.1
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.

Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry) (선택적다중이온질량분석기를 이용한 대기 중 휘발성유기화합물 실시간 동시분석법 개발 및 적용)

  • Son, Hyun Dong;An, Joon Geon;Ha, Sung Yong;Kim, Gi Beum;Yim, Un Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.393-405
    • /
    • 2018
  • Volatile organic compounds (VOCs) are representative air pollutants due to their detrimental effects on human health and their role in formation of secondary organic aerosols. Assessments and monitoring programs of VOCs using periodic grab sampling like Tedlar bags, canisters, and sorbent traps provide limited information, often with delay times of days or weeks. Selected ion flow tube mass spectrometry (SIFT-MS) is an emerging analytical technique for the real-time quantification of VOCs in air. It relies on chemical ionization of the VOCs molecules in air introduced into helium carrier gas using $H_3O^+$, $NO^+$, and $O_2{^+}$ precursor ions. Real-time monitoring method of 60 VOCs in the ambient air was developed using TO-15 standard gas mixture. Calibration curves, method detection limit, and quantitation reproducibility of the target compounds were tested. Dynamic dilution system was used to dilute standard gas from 0.174 ppbv to 100 ppbv, where calibration curves showed good linearity with $r^2$> 0.95 in all target analytes. Limit of detection (LOD) all compounds were sub ppbv, and some halogenated compounds showed pptv levels. Seven consecutive analyses of target compounds showed good repeatability with relative standard deviation of less than 10%. One day monitoring of VOCs in ambient air was conducted in Geoje. Average concentration of target VOCs in Geoje were relatively lower than other regions, among which formaldehyde showed the highest concentration ($15.4{\pm}5.78ppbv$). SIFT-MS provided good temporal resolution data (1 data per 3.2 minute), which can be used for identifying ephemeral short-term event. It is expected that SIFT-MS will be a versatile monitoring platform for VOCs in ambient air.

A Study on the Calibration of Simulation Characteristics of Live-Virtual Simulator System : To Impose Restrictions on a Maneuverability of a Simulated Aircraft Due to Pilot's G-force (Live-Virtual 시뮬레이터 모의특성 보정에 관한 연구 : 중력가속도에 따른 조종사의 기동제한 특성 기반)

  • Park, Myunghwan;Yoo, Seunghoon;Seol, Hyeonju;Kim, Cheonyoung;Hong, Youngseok
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, Korea Air Force has been facing a lot of problems in its pilot training system such as training time shortage due to the expensive gas price, noise pollution and difficulties in finding airspace for training. To tackle these problems, a new training system (called L-V training system) using both aircraft and its simulator has been suggested. In the system, a data link is established between aircraft and simulator to exchange their flight information. Using the flight information of simulator, aircraft can perform various air missions with or against imaginary aircraft (i.e., simulator). For this system, it is crucially important that fair fighting condition has to be guaranteed between aircraft and simulator. In this paper, we suggested an approach to impose a maneuvering restriction to simulator in order to provide fair fighting condition between aircraft and simulator.

Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard (물 흡수선량 표준에 기반한 선량교정 프로그램 개발)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.175-183
    • /
    • 2003
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma (or exposure) calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to the uncertainty of the physical parameters used. Recently, the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocols(IAEA TRS-398 and AAPM TG-51). The dose calibration programs for these two protocols were developed. This program for high energy photon and electron beams was also developed for users to use in a window environment using the Visual C++ language. The formalism and physical parameters of these two protocols were strictly applied to the program. The tables and graphs of the physical data, and the information of ion chambers were numericalized for their incorporation into a database. This program can be useful in developing new dosimetry protocols in Korea.

  • PDF

Existing Building Energy Simulation Method Using Calibrated Model by Energy Audit Data (성능진단 데이터로 보정된 모델을 이용한 기존건축물의 에너지시뮬레이션 기법)

  • Kong, Dong-Seok;Kim, Du-Hwan;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.231-239
    • /
    • 2014
  • This paper represents a method of existing building energy simulation using energy audit data. Energy audit must be carried out for reasonable analysis, because characteristics of existing buildings such as efficiency of fan, pump, flow rate, pressure, COP and operating schedule could be changed during the building operation. These building characteristics should be measured to estimate actual energy consumption of the existing building. In this study, we conducted energy audit and calculated energy savings for a 7-stories building as a case-study. The energy audit data were used to calibrate the building model of EnergyPlus simulation. Baseline model validated according to M&V guideline index. As a result, building characteristics are significant parameters making a big impact on energy savings in existing buildings.

Acetone PLIF for Fuel Distribution Measurements in Liquid Phase LPG Injection Engine (LPG 액상분사 엔진에서 아세톤 PLIF를 이용한 연료분포 측정기법 연구)

  • 오승묵;박승재;허환일;강건용;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.74-82
    • /
    • 2004
  • Planar laser-induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Acetone PLIF is chosen because fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone PLIF is applied to measure quantitative air excess ratio distribution in an engine fueled with LPG. Acetone is excited by KrF excimer laser (248nm) and its fluorescence image is acquired by ICCD camera with a cut-off filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile is suggested. Raw images are divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which is taken by a calibration process, are converted to air excess ratio distribution. This investigation shows instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

Study on Improvement in Reliability of Analysis for VOCs and Aldehydes (대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰)

  • Lee M.D.;Lee S.U.;Lim Y.J.;Kim Y.M.;Kim S.Y.;Moon K.J.;Han J.S.;Chung I.R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.

Evaluation on the Effect of Ultrasonic Testing due to Internal Medium of Pipe in Nuclear Power Plant (원자력발전소 배관 내부 매질이 초음파검사에 미치는 영향 평가)

  • Yoon, Byung Sik;Kim, Yong Sik;Yang, Seung Han
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.25-30
    • /
    • 2013
  • The periodic inspection of piping and pressure vessels welds in nuclear power plant has to provide reliable result related to weld flaws, such as location, maximum amplitude response, ultrasonic length, height and finally the nature or flaw pattern. The founded flaw in ultrasonic inspection is accepted or rejected based on these data. Specially, the amplitude of flaw response is used as basic parameter for flaw sizing and it may cause some deviation in length sizing result. Currently the ultrasonic inspections in nuclear power plant components are performed by specific inspection procedure which describing inspection technique include inspection system, calibration methodology and flaw characterizing. To perform ultrasonic inspection during in-service inspection, reference gain should be established before starting ultrasonic inspection by the requirement of ASME code. This reference gain used as basic criteria to evaluate flaw sizing. Sometimes, a little difference in establishing reference gain between calibration and field condition can lead to deviation in flaw sizing. Due to this difference, the inspection result may cause flaw sizing error. Therefore, the objective of this study is to compare and evaluate the ultrasonic amplitude difference between air filled and water filled pipe in nuclear power plant. Additionally, the accuracy of flaw sizing is estimated by comparing both conditions.

Validation and Calibration of TUNVEN Model (TUNVEN 모형의 검증 및 보정)

  • Cheong, Jang-Pyo;Yoon, Sam-Seok;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.785-796
    • /
    • 2000
  • In this study, the possibility of application of TUNVEN model was investigated through the validation and calibration processes. In order to validate and calibrate the TUNVEN model developed in USA to obtain prediction of the quasi-steady state longitudinal air velocities and the pollutants concentrations by solving the coupled one-dimensional steady state tunnel aerodynamic and advection equations. The major input parameters such as the concentration data for CO and $NO_x$, meteorological data and traffic volume in Hawngryung tunnel were measured. Prior to preparing the input parameters, the sensitivity analysis was conducted to identify the input parameters which need to be most accurately estimated in TUNVEN program. In order to establish the relationships between the model values and the measured values, the linear regression analysis was applied. In linear regression analysis, the model values were taken as independent parameter(X) and the measured values were taken as dependent parameter(Y) for four cases of data sef. From the results of linear regression analysis, the correlation coefficient(r) for four cases were calculated more than 0.91 and the values of slope and interception were analyzed as 0.5~2.2 and 0.01~2.3 respectively. From the above results, we concluded that the suitability of TUNVEN model was identified in prediction the longitudinal pollutant concentrations in tunnel.

  • PDF