Study of Combustion Characteristics with Variations of Combustion Parameter in Ultra-Lean LPG Direct Injection Engine (연소제어인자의 변화에 따른 직접분사식 초희박 LPG엔진의 연소특성 연구)

  • Park, Yun Seo;Park, Cheol Woong;Oh, Seung Mook;Kim, Tae Young;Choi, Young;Lee, Yong Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.607-614
    • /
    • 2013
  • Nowadays, automotive manufacturers have developed various technologies to improve fuel economy and reduce harmful emissions. The ultra-lean direct injection engine is a promising technology because it has the advantage of improving thermal efficiency through the deliberate control of fuel and ignition. This study aims to investigate the development of a spray-guided-type lean-burn LPG direct injection engine through the redesign of the combustion system. This engine uses a central-injection-type cylinder head in which the injector is installed adjacent to the spark plug. Fuel consumption and combustion stability were estimated depending on the ignition timing and injection timing at various air-fuel ratios. The optimal injection timing and ignition timing were based on the best fuel consumption and combustion stability.

Effect of Embryo Number and Incubation Volume on the Development of Pre- and Post-implantation Mouse Embryos In Vitro (배아밀도와 배양액 용량이 착상전후의 생쥐배아의 체외 성장에 미치는 영향)

  • Kang, Byung-Moon;Cheon, Yong-Pil;Kim, Ji-Young;Kim, Jeong-Hee;Lee, Ji-Yun;Chae, Hee-Dong;Kim, Chung-Hoon;Chang, Yoon-Seok;Mok, Jung-Eun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.377-383
    • /
    • 1997
  • The effects of embryo number and incubation volume on the development of mouse embryos were evaluated. The growth rate of two-cell mouse embryos to attached blastocyst stage and the growth rate of blastocysts to early somite stage were assessed after culture in different incubation volumes and embryo densities. Embryos were collected from ICR female mice superovulated with pregnant mare serum gonadotropin and human chorionic gonadotropin and mated by ICR males. In experiment 1, groups of one, five, ten, twenty 2-cell embryos were cultured in 10-, 50-, 500-, 1000-${\mu}l$ drops of BWW media under mineral oil at $37^{\circ}C$ in a humidified atmosphere of 5% $CO_{2}$ and 95% air. As the incubation volume decreased, significantly (p<0.05) higher rates of embryos reached morular and blastocyst stage on day 3 and 4 culture, respectively. In experiment 2, groups of one, five, ten, twenty blastocysts were cultured in 1- and 2-ml volumes of CMRL 1066 media under same condition as in experiment 1. However the reverse was the result. Decreasing the number of embryos incubated per volume from 1 to 20 significantly (p<0.05) increased the number of blastocysts reaching the late egg cylinder (LEC) and early somite (ES) stage on day 6 and 8 culture, respectively, regardless of incubation volume. Blastocysts cultured in 2ml had higher (p<0.05) development rates to LEC and ES stage on day 6 and 8 culture, respectively, than embryos cultured in 1ml. Our results suggest that the effects of embryo number and incubation volume on the development of mouse embryos are stage specific and the shifting point was between hatching and EEC stage.

  • PDF

Development of Concrete Quality Inspection and Document Management System Using Mobile and Web Technologies (모바일 기술 및 웹을 활용한 콘크리트 품질시험 및 문서관리 시스템 개발)

  • Kim, Young-Suk;Lee, Jae-Kwon;Jung, Un-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.4
    • /
    • pp.193-205
    • /
    • 2008
  • Quality is an important keyword representing the corporate competitiveness and image in today' s construction industry. Especially in concrete construction, any problems or defects in fresh concrete can significantly degrade the entire quality and performance of the facility built. Thus, adequate quality inspection and testing must be exercised over the fresh concrete, if concrete with the required strength, durability and appearance is to be obtained. The testing of concrete delivered to the construction job site involves testing of fresh concrete and performing strength tests on hardened concrete. The principal tests conducted on fresh concrete include the slump test and tests for air and salt content. The temperature of fresh concrete should be checked out hot or cold weather concreting. The 7-day and 28-day strength of hardened concrete are also determined by compression tests on usually cylinder samples. However, it is very complex and time-consuming process requiring a lot of efforts to document those on-site concrete testing results and to accumulate their historical data. The primary objective of this study is to suggest a unique PDA and web-based system which enables an on-site quality manager to effectively conduct the concrete inspection and testing, automatically document and accumulate the collected historical data, and promptly obtain the approval from supervisors. Finally, it is anticipated that the effective use of the proposed PDA and web-based system would be able to improve reliability of the concrete quality inspection and testing data as well as significantly reduce the approval process.

The SEM and SPM Study on the Change of Machined Titanium Implant Surface following Various Laser Treatments (수종의 레이저로 임프란트 표면 처리 시 표면 형태의 변화에 대한 주사전자 및 주사탐침 현미경적 연구)

  • Kim, In-Kyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.451-463
    • /
    • 2001
  • Following the extensive use of implant, the incidence of peri-implantitis increases. Guided bone regeneration has been used for the optimal treatment of this disease. Because implant surface was contaminated with plaque and calculus, cleaning and detoxification were needed for the reosseointegration when guided bone regeneration was performed. Various mechanical and chemical methods have been used for cleaning and detoxification of implant surface, air-powder abrasive and oversaturated citrate were known to be most effective among these methods. However, these methods were incomplete because these could not thoroughly remove bacteria of implant surface, moreover deformed implant surface. Recent studies for detoxification of the implant surface using laser were going on, $CO_2$ laser and Soft Diode laser were known to be effective among these methods. The purpose of this study was to obtain clinical guide by application these laser to implant surface. 15 experimental machined pure titanium cylinder models were fabricated. The $CO_2$ laser treatment under dry, wet and hydrogen peroxide condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of models. Each groups were examined with SPM and SEM to know whether their surface was changed. The results were as follows : 1. Surface roughness and surface form weren't changed when $CO_2$ laser was usedunder dry condition(P>0.05). 2. Surface roughness and surface form weren't changed when $CO_2$ laser was used under wet condition(P>0.05). 3. Surface roughness and surface form weren't changed when $CO_2$ laser was used under hydrogen peroxide condition(P>0.05). 4. Surface roughness and surface form weren't changed when Soft Diode laser was used under toluidine blue O solution condition(P>0.05). From the result of this study, it may be concluded that the $CO_2$ laser having relatively safe pulse mode and the Soft Diode laser used with photosensitizer can be used safely to treat peri-implantitis.

  • PDF

A Study on Public Nuisance in Kwangju City (Survey on Air Pollution and Noise Level) (공해(公害)에 관(關)한 조사연구(調査硏究) -광주시(光州市)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 조사연구(調査硏究)-)

  • Chung, Yo-Han;Kim, Kil-Wng;Moon, Jae-Kyu;Jhoo, Heung-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 1972
  • During the period from June 1st 1971 to November 30 th 1971, studies on air pollution were made in Kwangju city. The city was divided into 6 areas; the downtown area, the semi-downtown area, the heavy traffic area, the commercial area, the residential area, the park area, 13 surveying sites were selected each representing the characteristics of the area. The Measurement methods which were used are described below. Sulfur oxides were measured by $PbO_2$ cylinder method, sulfur dioxides ($SO_2$) and carbon monoxide (CO) by the MSA & Kitakwa detector, dustfall by the Deposit gauge method, and the noise levels by the Kanomax soundlevel meter. The results obtained are as follows: 1. The mean value of sulfur oxides in Kwangju city was $1.16mg\;SO_3/day/100cm^2\;PbO_2$, ranging from $0.45mg\;SO_3/day/100cm^2\;PbO_2$ to $3.10mg\;SO_3/day/100cm^2\;PbO_2$. 2. The mean values of sulfur oxides according to its specific area in the city were $1.45mg\;SO_3/day/100cm^2\;PbO_2$ in heavy traffic area, 1.36 in downtown area, 1.23 in semi-downtown area, 1.11 in commercial area, 0.96 in residential area, and 1.07 in park area, respectively. 3. The average concentration of sulfur dioxide was 0.063 ppm from 2 to 5 P.M in Kwangju city. 4. The average concentrations of sulfur dioxides according to its specific area, from 2 to 5 P.M, in the city were 0.084 ppm in heavy traffic area & downtown area, 0.067 in commercial area, 0.053 in semi-downtown area, 0.052 in residential area, and 0.036 in park area. 5. The average concentration of carbon monoxide was 22.3 ppm from 2 to 5 P.M, in Kwangju city. 6. The average concentrations of carbon monoxide according to its specific area, from 2 to 5 P.M, in the city were 27.0 ppm in downtown area, 26.3 in semi-downtown area, 23.0 in heavy traffic area, 21.7 in commercial area, 20.0 in residential arera, and 17.6 in park area. 7. The mean value of dusifall in Kwangju city was $29.28ton/km^2/month$, ranging from $9.85ton/km^2/month$ to $66.34ton/km^2/month$. 8. The mean values of dustfall according to its specific area in the city were $50.37ton/km^2/month$ in semi-downtown area, 42.76 in heavy traffic area, 34.67 in downtown area, 17.77 in commercial area, 14.40 in park area, and 14.76 in residential area. 9. The mean values of the soluble dust in Kwangju city was $10.23ton/Km^2/month$ and that of the insoluble dust was $19.05ton/Km^2/month$. 10. The mean value of noise level in Kwangju city was 62 phon, ranging from 37 phon to 88 phon. 11. The mean values of noise level according to its specific area in the city were 76 phon in heavy traffic area, 67 in semi-downtown area, 64 in downtown area, 59 in commercial area, 52 in part area, and 50 in residential area.

  • PDF

Effects of Exhaust Gas Recirculation on Power and Thermal Efficiency of Reactivity Controlled Compression Ignition in Different Load Conditions with a 6-L Engine (6 L급 압축착화 기관에서 천연가스-디젤 반응성 조정 연소 시 부하에 따른 배기 재순환율이 출력 및 열효율에 미치는 영향 분석)

  • Lee, Sunyoup;Lee, Seok-Hwan;Kim, Chang-Gi;Lee, Jeong-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.1-10
    • /
    • 2020
  • Reactivity controlled compression ignition (RCCI) combustion is one of dual-fuel combustion systems which can be constructed by early diesel injection during the compression stroke to improve premixing between diesel and air. As a result, RCCI combustion promises low nitrogen oxides (NOx) and smoke emissions comparing to those of general dual-fuel combustion. For this combustion system, to meet the intensified emission regulations without emission after-treatment systems, exhaust gas recirculation (EGR) is necessary to reduce combustion temperature with lean premixed mixture condition. However, since EGR is supplied from the front of turbocharger system, intake pressure and the amount of fresh air supplementation are decreased as increasing EGR rate. For this reason, the effect of various EGR rates on the brake power and thermal efficiency of natural gas/diesel RCCI combustion under two different operating conditions in a 6 L compression ignition engine. Varying EGR rate would influence on the combustion characteristic and boosting condition simultaneously. For the 1,200/29 kW and 1,800 rpm/(lower than) 90 kW conditions, NOx and smoke emissions were controlled lower than the emission regulation of 'Tier-4 final' and the maximum in-cylinder pressure was 160 bar for the indurance of engine system. The results showed that under 1,200 rpm/29 kW condition, there were no changes in brake power and thermal efficiency. On the other hand, under 1,800 rpm condition, brake power and thermal efficieny were decreased from 90 to 65 kW and from 37 to 33 % respectively, because of deceasing intake pressure (from 2.3 to 1.8 bar). Therefore, it is better to supply EGR from the rear of compressor, i.e. low pressure EGR (LP-EGR) system, comparing to high pressure EGR (HP-EGR) for the improvement of RCCI power and thermal efficiency.

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF

Experimental Research on the Power Improvement by Increasing Intake pressure in a 1.4 L Turbocharged CNG Port Injection Spark Ignition Engine (1.4L 급 터보 CNG 엔진에서 흡기압력 상승에 따른 출력 증대 효과에 관한 연구)

  • Lee, Jeong-Woo;Park, Cheol-Woong;Bae, Jong-Won;Kim, Chang-Gi;Lee, Sun-Youp;Kim, Yong-Rae
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.90-96
    • /
    • 2019
  • Natural gas has been regarded as one of major alternative fuels, because of the increment of mining shale gas and supplying PNG(Pipeline Natural Gas) from Russia. Thus, it needs to broaden the usage of natural gas as the increasing its supplement. In this situation, application of natural gas on the transport area is a good suggestion to reduce exhaust emissions such as CO2(carbon dioxides) and soot from vehicles. For this reason, natural gas can be applied to SI(spark ignition) engines due to its anti-knocking and low auto-ignitibility characteristics. Recently, since turbocharged SI engine has been widely used, it needs to apply natural gas on the turbocharged SI engine. However, there is a major challenge for using natural gas on turbocharged SI engine, because it is hard to make natural gas direct injection in the cylinder, while gasoline is possible. As a result, there is a loss of fresh air when natural gas is injected by MPI (multi-point injection) method under the same intake pressure with gasoline-fueled condition. It brings the power reduction. Therefore, in this research, intake pressure was increased by controling the turbocharger system under natural gas-fueled condition to improve power output. The goal of improved power is the same level with that of gasoline-fueled condition under the maximum torque condition of each engine speed. As a result, the maximum power levels, which are the same with those of gasoline-fueled conditions, with improved brake thermal efficiency could be achieved for each engine speed (from 2,000 to 6,000 rpm) by increasing intake pressure 5-27 % compared to those of gasoline-fueled conditions.

Investigation on Diesel Injection Characteristics of Natural Gas-Diesel Dual Fuel Engine for Stable Combustion and Efficiency Improvement Under 50% Load Condition (천연가스-디젤 혼소 엔진의 50% 부하 조건에서 제동효율 및 연소안정성 개선을 위한 디젤 분무 특성 평가)

  • Oh, Sechul;Oh, Junho;Jang, Hyungjun;Lee, Jeongwoo;Lee, Seokhwan;Lee, Sunyoup;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.45-53
    • /
    • 2022
  • In order to improve the emission of diesel engines, natural gas-diesel dual fuel combustion compression ignition engines are in the spotlight. In particular, a reactivity controlled compression ignition (RCCI) combustion strategy is investigated comprehensively due to its possibility to improve both efficiency and emissions. With advanced diesel direct injection timing earlier than TDC, it achieves spontaneous reaction with overall lean mixture from a homogeneous mixture in the entire cylinder area, reducing nitrogen oxides (NOx) and particulate matter (PM) and improving braking heat efficiency at the same time. However, there is a disadvantage in that the amount of incomplete combustion increases in a low load region with a relatively small amount of fuel-air. To solve this, sensitive control according to the diesel injection timing and fuel ratio is required. In this study, experiments were conducted to improve efficiency and exhaust emissions of the natural gas-diesel dual fuel engine at low load, and evaluate combustion stability according to the diesel injection timing at the operation point for power generation. A 6 L-class commercial diesel engine was used for the experiment which was conducted under a 50% load range (~50 kW) at 1,800 rpm. Two injectors with different spray patterns were applied to the experiment, and the fraction of natural gas and diesel injection timing were selected as main parameters. Based on the experimental results, it was confirmed that the brake thermal efficiency increased by up to 1.3%p in the modified injector with the narrow-angle injection added. In addition, the spray pattern of the modified injector was suitable for premixed combustion, increasing operable range in consideration of combustion instability, torque reduction, and emissions level under Tier-V level (0.4 g/kWh for NOx).