• 제목/요약/키워드: Air Conditioning Unit

검색결과 377건 처리시간 0.031초

클린룸 내 롤러 컨베이어 운송장치 주위의 유동해석 (Flow Analysis around the Roller Conveyor in a Clean Room)

  • 전현주;박찬우;임익태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1507-1512
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

  • PDF

가스터빈 열병합발전에서 생산된 열과 전기의 원가산정 (Cost Estimating of Heat and Electricity on a Gas-Turbine Cogeneration)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.351-356
    • /
    • 2008
  • When various kinds of outputs are produced from a single energy system, the methodology which allocates the common cost to each output cost is very important because it is directly related with the profit and loss of producers and purchasers. In the cost allocation methodology of the heat and the electricity on a cogeneration, there are energy method, work method, proportional method, benefit distribution method, various exergetic methods, and so on. On the other hand, we have proposed a worth evaluation method which can be applied to any system. The definition of this methodology is that the unit cost of a product is proportion to the worth. Where, worth is a certain evaluating basis that can equalize the worth of products. In this study, we applied this methodology to a gas-turbine cogeneration which produces 119.2 GJ/h of electricity and 134.7 GJ/h of heat, and then we allocated 3,150 $/h of fuel cost to electricity cost and heat cost. Also, we compared with various cost allocation methods. As the result, we conclude that exergy of various kinds of worth basis evaluates the worth of heat and electricity most reasonably on this system.

  • PDF

시스템 히트펌프의 용량조절 및 다변수 제어 특성에 관한 연구 (The Performance of Capacity Modulation and MIMO Control for System Heat Pump)

  • 송인식;주영주;정현준;강훈;김용찬;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2007
  • A system heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the system heat pump has been employed in small and medium-sized buildings. However, the performance data and control algorithm for system heat pump are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of a system heat pump with two indoor unit is measured by varying indoor loads, EEV opening, and compressor speed. In addition, the integral optimum regulator which includes MIMO control algorithm is proposed. The capacity modulation and optimum capacity for each indoor unit can be adjusted by utilizing the EEVs opening and compressor speed. The proposed scheme shows appropriate control performance at test conditions.

  • PDF

대구시 공공건축물의 에너지 소비 원단위에 관한 연구 (An Analysis on the Energy Consumption Unit of the Public buildings in Daegu)

  • 최정희;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF

지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구 (A Study on the Certified Ground Source Heat Pump and Performance Analysis)

  • 양찬우;강희정;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.

사무소 건축의 공공화장실 실내설계 기법에 관한 연구 (A Study on the Interior Design Method of Public-Toilet in Office Building)

  • 김정범;김은중
    • 한국실내디자인학회논문집
    • /
    • 제16호
    • /
    • pp.16-21
    • /
    • 1998
  • This study aims at developing the interior design method of Public Toilet in office building. There needs new concepts in Public Toilet where we felt dirty smelling and dismal in the past. And the behavior in the Public Toilet become various such as combing the hair making-up changing the clothes rinsing out mouth and so on. Nowadays The Public Toilet of office building shows indirectly the hierarchy and the management philosophy of its enterprise, This study treats with the design items such as unit space zoning plan lighting plan and air-conditioning plan and construction method of Public-Toilet in office building. As a result of this study the interior design methods of Public Toilet must reflect use of fitting material lighting plan user's needs and functional divide.(Powder Zone and Physiology Zone) These result will become basic data of future interior design in Public Toilet.

  • PDF

위상 최적 설계를 이용한 로터리 콤프레셔의 소음 저감 (SOUND REDUCTION OF ROTARY COMPRESSOR USING TOPOLOGY OPTIMIZATION)

  • 왕세명;박종찬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1168-1173
    • /
    • 2001
  • Compressors are the main source of noise of refrigerators and air-conditioning unit. Recent studies on the sound propagation of rotary compressors showed that the accumulator is a significant source of noise generation. This paper describes a design change of a rotary compressor for noise reduction using topology optimization. Topology optimization has been developed and used to find the most effective structural configuration in the early stage of design procedures. FE model of the rotary compressor composed of all the components is built for the topology optimization. Topology optimization results show that the empirical design for the present structure fail to constrain some resonance modes and a new component is required.

  • PDF

정압을 이용한 직교류팬 주변의 소음 예측 (Estimation of Noise Level near Cross Bow Fan by Measurements of Static Pressure.)

  • 김재원;조용;정윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1156-1161
    • /
    • 2001
  • A significant trial has been performed for estimation of noise level of a cross flow fan for air conditioning system. In general, measurements of noise level of machinery require rigorous equipment involving an anechoic chamber with precision gauges. The apparatus is expensive to utilize and is not easy to construct. In this work, we adopt static pressure sensing from an ordinary pressure transducer for prediction of noise level of a rotating fan. The present procedure is finding sound pressure from the static pressure by manipulating Light-Curle equation depicts noisy energy in terms of pressure on surfaces of noise generators. Sound power level near core unit of the fan is evaluated with the present methodology in a normal laboratory room without any sound absorbers. The method is easy and shows good prediction results compared with precise measurements by using microphones.

  • PDF