• 제목/요약/키워드: Air Conditioning Unit

검색결과 378건 처리시간 0.02초

슬래브축열 공조시스템의 축열성능에 관한 실험적 연구 (An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

룰 베이스를 이용한 공조기의 고장검출 및 진단 (Fault Detection and Diagnosis of an Air Handling Unit Based on Rule Bases)

  • 한도영;주명재
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.552-559
    • /
    • 2002
  • The fault detection and diagnosis (FDD) technology may be applied in order to decrease the energy consumption and the maintenance cost of the air conditioning system. In this study, rule bases and curve fitting models were used to detect faults in an air handling unit. Gradually progressed faults, such as the fan speed degradation, the coil water leakage, the humidifier nozzle clogging, the sensor degradation and the damper stoppage, were applied to the developed FBD system. Simulation results show good detections and diagnoses of these faults. Therefore, this method may be effectively used for the fault detection and diagnosis of the air handling unit.

차륜형 대공포 냉방장치 성능개선 연구 (Study on Improvement of Air Conditioning Units for Anti Aircraft Gun Wheeled Vehicle)

  • 전기현;이동희;이부환
    • 대한기계학회논문집B
    • /
    • 제37권12호
    • /
    • pp.1099-1103
    • /
    • 2013
  • 과거의 무기체계는 체계의 목적과 비용 등의 문제로 운용환경에 대한 관심이 부족하였으며, 특히 냉방장치가 미탑제된 체계가 많이 개발되었다. 근래 개발되는 무기체계는 고도의 정밀조준 및 고감도 시스템으로 진화함에 따라 무기체계를 효과적으로 제어하기 위하여 운용자의 운용환경도 중요한 요소로 대두되고 있다. 현재의 무기개발자들은 대부분 통합형 환경제어장치를 장착하도록 설계하고 있다. 본 연구에서는 장갑차량의 운용환경 및 설계조건을 바탕으로 한국군의 운용환경에 적합한 냉방기 및 냉방 부하를 검토하고 시제품의 냉방성능 시험결과가 목표성능에 미달되어 이에 대해 개선내용 및 검토결과를 기술하였다.

혼합 공조 시스템의 EER(A) 평가 (Evaluation of energy efficiency ratio in the mixed air conditioner system)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.542-548
    • /
    • 1999
  • Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.

  • PDF

차량용 CO2 에어컨 사이클 성능 향상을 위한 일체형 팽창기-압축기 성능 해석 (An Analysis of the Performance of a Combined Expander-Compressor Unit for a CO2 Automotive Air Conditioning Cycle)

  • 최재웅;임정택;김현진
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.107-115
    • /
    • 2018
  • A design combining the use of a compressor and expander was introduced in order to improve the cycle performance of a $CO_2$ automotive air conditioning system. Both the compressor and expander used were of rotary vane type and were designed to share a common shaft in a housing. Numerical simulation was carried out to evaluate the merit of the combined unit. In a typical automotive air conditioning operating conditions, the COP of the system was improved by 8.7% by the application of the combined unit. The compressor input was reduced by 5.2% through use of the expander output. In addition, about 3.06% increase in the cooling capacity was obtained through isentropic expansion in the expander. Our study noted that, as the pressure difference between the gas cooler and the evaporator becomes larger, the COP of the system improved increases unless the mass flow rate in the expander exceeds that in the compressor.

인간의 열적 적응성을 고려한 퍼스널 공조시스템의 개발 (Study on the Personal Air-Conditioning System Considering Human Thermal Adaptation)

  • 송두삼
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.524-532
    • /
    • 2003
  • In this paper, a personal air-conditioning system considering the human thermal adaptability is analyzed. Although the conventional personal air-conditioner was proofed to be satisfactory in providing for the thermal comfort, it is being questioned on the term of its energy efficiency. Therefore, it is important and urgent to develop new types of personal air-conditioning system with sustainable control strategy that can ensure energy saving and thermal comfort simultaneously. In this study, we first examined the problems of the conventional personal air-conditioning system with field interview and laboratory experiment in terms of usage, management and thermal comfort, and proposed the energy-saving personal air-conditioning system considering the human thermal adaptation. Then a laboratory experiment was performed to analyze the characteristics of the human thermal comfort under severe indoor thermal conditions, which were controlled using a new personal air-conditioning unit designed according to the proposal. The results help to illustrate the alleviation effect of the new personal air-conditioning system, and indicate that the thermal alleviation time is useful to maintain the thermal comfort with efficient usage of energy.

비개방형 포탑드럼바스켓을 가진 대공포체계의 냉방장치개선 연구 (Study on Improvement in Cooled Air Defense Gun System Including Closed Drum Basket)

  • 황부일;이동희;김치환
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.109-113
    • /
    • 2015
  • 과거의 무기체계는 체계의 목적과 비용 등의 문제로 운용환경에 대한 관심이 부족하여 특히 냉방장치가 탑재되지 않은 체계가 많이 개발되었다. 근래 개발되는 무기체계는 고도의 정밀조준 및 고감도 시스템으로 진화함에 따라 무기체계를 효과적으로 제어하기 위하여 운용자의 운용환경도 중요한 요소로 대두되고 있다. 현재의 무기개발자들은 대부분 통합형 환경제어장치를 장착하도록 설계하고 있다. 본 연구에서는 기 개발된 내부 탄통을 가진 대공포 장갑차에서, 포탑이 회전을 하더라도 효율적으로 차가운 냉기를 전달할 수 있게 하기 위해 드럼바스켓 해석 및 시험을 통해 냉방개선 방안을 도출하고 결과를 실제 장비에 적용하였다.

퍼지 알고리즘을 이용한 정풍량 공조기의 고장 감지 및 진단 (Fault Detection and Diagnosis of a Constant Volume Air Handling Unit by a Fuzzy Algorithm)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.444-451
    • /
    • 2005
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this study, partial faults for fans, coils, dampers, and sensors of a constant volume air handling unit were considered. A fuzzy algorithm was developed to detect and diagnose these faults. Diagnostic results by the fuzzy algorithm were compared with those by the model reference algorithm. The fuzzy algorithm showed better results in diagnostic accuracies.

사계절 외기 전용 공조기에 대한 실험적 연구 (An Experimental Study on Four-season Dedicated Outdoor Air Handling Unit)

  • 박승태;김종천;홍영주;김영일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.577-582
    • /
    • 2008
  • The present study has been conducted to study the performance of Dedicated outdoor air handling unit. Dedicated outdoor air handling unit consists of pre-cooler, dehumidification and after cooler. By combining dedicated outdoor air-conditioning and heat pump, a new four-season dedicated outdoor air handling unit has been developed. Amount of energy saved and condition when this new system is superior to conventional vapor-compression cooling system has been presented.

  • PDF