• Title/Summary/Keyword: Air Conditioner Noise

Search Result 142, Processing Time 0.024 seconds

Survey on the Uses of Heating-Cooling Facilitis.Accessory Devices and Residents' Evaluation in Cheju Province (제주도 지역 냉난방 설비.보조기구 사용실태와 거주자의 평가)

  • 김봉애
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.239-248
    • /
    • 1997
  • to design nature-affinitive, reasonable and effcient thermal environment plannings and facilities, the holding patterns of heating-cooling facilities·accessory devices and residents' evaluation in Cheju Province were surveyed as well as residents' understanding for them. Major findings of this study are summarized as follows: 1) In the cooling system, the percentage of air-conditioner possessor was 19.4%, which was lower possessive rate than mainland's. The location of air-conditioner was mainly public area. That is, 55.3% of the location is livingroom, and the rest was Anbang. the general cooling accessory device was a fan. It was frequently used at the children's room and the dining room. The possessive patterns of air-conditioner depend on the characteristics of residents, such as the academic carrier and the average monthly income. Characteristics of house for air-conditioner possess depend on the location, house type, the size of floor space. 2) In the heating system, individual heating system reached to 57.3%. Heating accessory devices were oil stove and electric heating blanket. Only 32.2% of survey population were holders. 3) Residents preferred better ventilated room arrangement, which was characteristic of subtropical areas. 4) The preferred condition for heating-cooling facilities and accessory devices were strong solidity, less air pollution, and less noise.

  • PDF

Vibration Analysis of Rotary Compressor based on Vibration Intensity (진동인텐시티를 이용한 로타리압축기 진동 해석)

  • 안병하;이장우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.166-172
    • /
    • 2003
  • Vibration and Noise of air conditioner are entirely determined by compressor vibration. Compressor vibration transmitted to the enclosure of air conditioner or pipes connected compressor with heat exchanger. Enclosure generate(noise and vibration. Therefore, the analysis of compressor vibration analysis is considered significant technical issue. For the reduction of vibration of compressor, it is necessary to grasp correctly vibration transmission paths and excitation sources in the compressor shell. Because, shell ( Surface of compressor ) shows whole vibration characteristic of compressor mechanism. In this paper, vibration intensity was applied to measure vibration energy flow on the shell .From this technique, it is possible to catch the path of vibration propagation along the one cycle and the location of vibration energy sources may change with time on the shell.

A Study of Stabilizer for the Noise Reduction in Room Air Conditioner (룸에어컨 소음저감을 위한 Stabilizer에 관한 연구)

  • 서상호;이내영;이진하;진심원;임금식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.136-141
    • /
    • 1995
  • Room Air Conditioner(이하 RAC) 실내기는 열교환기, Cross Flow Fan(이하 CFF), 곡률, Stabilizer(이하 STB) 등 여러 설계인자가 소음, 풍량 및 압력 등에 상호 복합적으로 연성(Coupled)되어 있어 각 인자가 성능에 미치는 영향을 정량적으로 밝혀 내기가 쉽지 않다. 따라서 RAC 실내기의 고성능 및 저소음화를 실현하기 위해서는 실내기를 구성하는 각 인자간의 상호 관련성 및 각 인자가 소음.성능 등에 미치는 영향을 체계적으로 분석하는 것이 필수적이다. 본 연구에서는 설계인자중 소음 및 풍량에 민감한 영향을 주는 STB 위치 및 형상 등에 관하여 자세히 다루고자 한다. STB위치의 적절한 범위를 설정하기 위해 Laser Doppler Velicitimeter(이하 LDV)를 이용하여 곡률별 실내기 내부의 유속분포 및 속도 벡터를 측정하였고, CFF내부 Vortex의 정확한 위치를 찾아냈다. 또한 실내기 저소음화를 위한 소음원 규명 측면에서 실내기 내부의 난류도와 관련하여 속도 Fluctuation을 정의하고, 실험을 통해 구하였다.

  • PDF

A Study on the Sound Paths of Air-conditioner in House (주거 공간내 공조기 소음의 전달 경로에 관한 연구)

  • 최진권;손진희;장서일;이진교;김진섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.522-528
    • /
    • 2001
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were reflected on the simulated results.

  • PDF

The prediction of sound transmission from air-conditioner outdoor-units in multi-unit housings (공동주택 에어컨 실외기의 투과소음 예측 및 저감방안에 관한 연구)

  • Choi, Jin-Kwen;Chang, Seo-Il;Lee, Jin-Kyo;Kang, Jeong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.996-1001
    • /
    • 2000
  • The sound transmission from the machine room where air-conditioner outdoor unit is located into the adjacent room is predicted and evaluated. The software package for statistical energy analysis(SEA) is utilized to determine the transmission losses of multi-layerd panels. To determine the noise level in the machine room, ray tracing method is adopted. The various sound transmission paths have been effectively identified and evaluated by the SEA tool.

  • PDF

Fan Noise Prediction Method of Air Cooling System (공기 냉각 시스템의 홴 소음 예측 기법)

  • Lee, Chan;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.952-960
    • /
    • 2008
  • Fan noise prediction method is presented for air conditioning, automobile and electronic cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(flow network modeling). Fan noise prediction method comprises two models for the discrete frequency noise due to rotating steady aerodynamic lift and blade interaction and for the broadband noise due to turbulent boundary layer and wake vortex shedding. Based on the fan operation point predicted from the FNM analysis results and fan design parameters, the present far noise model predicts overall sound pressure level and spectrum. The predictions for the flow distribution, the fan operation and the noise level in air cooling system by the present method are well agreed with 3-D CFD and actual noise test results.

Vibration Analysis of Compressor and Pipe Using RecurDyn (RecurDyn 을 이용한 압축기 및 배관 진동 해석)

  • Kwon, Seungmin;Son, Youngboo;Ha, Jonghun;Yoo, Hong Hee
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.2
    • /
    • pp.117-124
    • /
    • 2015
  • Recently, noise reduction in room air conditioner has been one of the most important issues as well as cooling efficiency. A rotary compressor is widely used in room air conditioners. But, the rotary compressor is the dominant vibration/noise source in an air conditioner. A number of studies have been conducted on reducing rotary compressor vibration/noise through improving muffler and resonator design. However, a noise delivering path between compressor and pipe is not fully taken into consideration. In this paper, the vibration analysis model of rotary compressor is modeled using RecurDyn and experimental validation is presented.

Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit (분리형 에어컨의 실내기 냉매 소음 저감 분석)

  • Aoyama Shigeo;Mo, Jin-Yong;Lee, Jae-Kwon;Song, Yong-Jae;Han, Hyung-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.240-246
    • /
    • 2006
  • In the air-conditioner, refrigerant induced noise and vibration can be increased when the airflow rate is reduced in order to decrease the noise at the low mode. Through the test and analysis of this kind of noise, it can be verified that the main reasons of refrigerant induced noise are the velocity and flow Induced force of the refrigerant at the inlet of the evaporator, So, in order to reduce this velocity, quality at the evaporator inlet should be minimized. And, in order to reduce flow induced force of the refrigerant, sudden change of fluid flow must not be occurred. So, in this paper, we will review the characteristics of refrigerant cycle and find how the quality and flow induced force can be minimized.

Optimum Design of an Indoor Package Air-Conditioner's Flow Path by Taguchi Method (다구찌 방법에 의한 PAC 실내기 유로의 최적설계)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 2014
  • In this study, the optimum design process of an indoor package air-conditioner (PAC) was implemented by Taguchi method. The goal of this study is to obtain the best set condition of each control factor composing of an indoor PAC. The number of revolution of a double inlet sirocco fan installed in an indoor PAC was measured by the orthogonal array of $L_{18}(2^3{\times}3^4)$ and analysed by using the-smaller- the-better characteristic among the static characteristic analyses. As a result, the optimum condition of an indoor PAC was found as a set of when the cost of production, assembling and working conditions were considered. Moreover, the number of revolution of a double-inlet sirocco fan used for an optimum condition was reduced about 8.5% more than that of a standard condition for the target flowrate of $18.5m^3/min$.

PERFORMANCE ASSESSMENT OF THE RANS TURBULENCE MODELS IN PREDICTION OF AERODYNAMIC NOISE FOR AIR-CONDITIONER INDOOR UNIT (에어컨 실내기의 공력소음 예측을 위한 RANS 난류모델의 성능 평가)

  • Min, Y.H.;Kang, S.;Hur, N.;Lee, C.;Park, J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.81-86
    • /
    • 2012
  • The objective of the present study is to investigate the effects of various turbulence models on the aerodynamic noise of an air-conditioner (AC) indoor unit. The results from URANS (unsteady Reynolds-averaged Navier-Stokes) simulations with the standard k-$\varepsilon$, k-$\omega$ shear stress transport (SST) and Spalart-Allmaras (S-A) turbulence models were analyzed and compared with the noise data from the experiments. The frequency spectra of the far-field acoustic pressure were computed using the Farrasat equation derived from the Ffowcs Williams-Hawkings (FW-H) equation based on the acoustic analogy model. Two fixed fan casings and the rotating cross-flow fan were used as the source surfaces of the dipole noise in the Farrasat equation. The result with the standard k-$\epsilon$ model showed a much better agreement with the experimental data compared to the k-w SST and S-A models. The differences in the pressure spectra from the different turbulence models were discussed based on the instantaneous vorticity fields. It was found that the over-estimated power spectra with the k-w SST and S-A models are related to the emphasized small-scale vortices produced with these models.