• 제목/요약/키워드: Air Conditioner Compressor

검색결과 165건 처리시간 0.026초

로터리 컴프레서 방사소음의 실험적 저감 (Experimental Reduction of the Noise Radiated by Rotary Compressor)

  • 박상영;이상현;이수일;이장무
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.189-195
    • /
    • 1999
  • The noise radiated by the rotary compressor for a room air-conditioner was investigated experimentally. Noise characteristics and structural eigen modes of the compressor were identified through sound tests and modal tests each other. From these tests. we found that the accumulator has a big contribution to the noise radiation. So, various structural modifications for the accumulator were performed and these modification methods were found efficient to the noise reduction from verification tests.

  • PDF

냉장 차량용 듀얼 컴프레서 인버터 시스템 (Dual Compressor Inverter System for Refrigerator Vehicles)

  • 한근우;김성곤;이충훈;최명현;정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.292-293
    • /
    • 2017
  • In the single type mechanical compressor mounted on the refrigerated vehicle, one compressor is responsible for the refrigerator function of the air conditioner and the refrigerator, so it is difficult to maintain a certain refrigeration temperature in the summer. Particularly, in a mechanical compressor using an engine as a power source, the refrigeration quality is deteriorated due to unstable rotation of the engine. In this paper, we propose a three - phase inverter of a dual compressor system that uses an electric compressor separately from a mechanical compressor of a refrigerated vehicle. The output characteristics of the developed inverter were verified through a vehicle air conditioning simulator.

  • PDF

에어컨 압축기 진동전달률 개선을 위한 그로메트 연구 (A Study of Improving Transmissibility for Grommets in Air conditioner Compressor)

  • 박홍을;이재권;모진용;박득용;한형석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.651-655
    • /
    • 2004
  • This paper studies the designing method and application for grommets, rubber material used to absorb vibration on the air conditioner compressor. The existing grommet with hardness 40 degrees, EPDM, has the high transmissibility on the compressor that causes additional structure born sound. The problem for EPDM is transformation over long time usage possibly due to its design in which stress is concentrated on a certain position. In order to resolve it, silicon material was previously used with the same design in some models. The vibration performance did improve, but the cost became high. Below are the major developments regarding improvements in compressor rubber material, vibration performance and durability through design change, and new grommet to attain cost reduction. 1 The optimum grommet design for stress even distribution through FEM methods. 2. Comparison for grommet material and design for improved transmissibility. 3. Assess for grommets durability and product applications.

  • PDF

실외온도 변화에 따른 R410A 적용 에어콘 시스템의 성능 (Performance of a room air conditioner using R410A according to the variation of outdoor temperature)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.537-541
    • /
    • 1999
  • The system performance of a room air conditioner using R410A was experimentally evaluated and compared with that of R22 system. The results indicated that the cooling EER(energy efficiency ratio) of R410A was 1% higher than that of R22 at the outdoor temperature of $35^{\circ}C$. As outdoor temperature increases above $35^{\circ}C$ ambient, EER of the R410A system decreased more substantially compared with R22 system. R410A showed higher compressor discharge temperature than that of R22 system at the outdoor temperature of higher than $50^{\circ}C$.

  • PDF

가정용 에어컨 실외기의 기동 소음 분석 (The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner)

  • 손영부;이승목;하종훈;이병철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로 (Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method)

  • 정용채;정윤철;권경안
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

Development of Hybrid Electric Compressor Motor Drive System for Hybrid Electrical Vehicles

  • Jung, Tae-Uk
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.960-968
    • /
    • 2009
  • This paper presents a design optimization process for interior permanent magnet synchronous motors (IPMSM) for hybrid electric compressors (HEC) which are applied to hybrid electrical vehicles. A hybrid electric compressor is composed of an electric motor driving section and an engine driving section which is connected to the engine by a pulley belt. A hybrid electric compressor driving motor requires half of the full driving power of a compressor. Even though an engine is not operated at the idling stop mode, the electric motor drives the air-conditioner compressor by itself so that the air conditioning system can produce its minimum cooling capacity. In this paper, the design optimization of an IPMSM for a 42 (V) applied voltage system is studied using the design of experiment (DOE) and response surface method (RSM) of 6sigma. The driving characteristics of this motor drive system are measured and analyzed by experiment.

동시냉난방 시스템 에어컨의 고낙차 장배관 운전 신뢰성 평가 (Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner with high-head and long-line conditions)

  • 김태안;이승찬;태상진;정규하;문제명;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.609-614
    • /
    • 2008
  • The heating and cooling performance of system multi-air conditioner under high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with 22 different working conditions. Experimental results were prepared on the p-h diagram. Also the oil level in the compressor was normally maintained at the safety zone for the system multi-air conditioner with high-head and long-line conditions.

  • PDF

밀폐형압축기용 전동기및 그 보호장치에 관하여 (Hermetically Sealed Refrigeration Compressor Motors and it's Protecting Device)

  • 경원기계공업㈜ 압축기연구실
    • 대한설비공학회지:설비저널
    • /
    • 제7권4호
    • /
    • pp.257-267
    • /
    • 1978
  • Hermetically sealed refrigeration comperessor use for household refrigerotor, room air conditioner, require effective performance, stable condifion. From now, I'm going to tell you about characteristics of motors, starters and protecting device for compressors.

  • PDF

재료비 절감을 위한 병렬구조를 갖는 인버터 에어컨용 역률제어회로 (Power Factor Correction Circuit For Inverter Air-Conditioner With A Parallel Configuration To Reduce The Material Cost)

  • 정용채;정윤철;권경안
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.122-127
    • /
    • 1999
  • 본 논문에서는 3마력의 컴프레샤 모터를 갖는 대용량의 인버터 에어컨의 원가절감과 성능향상을 위해서 병렬구동방식을 사용한 역률제어회로를 제안하였다. 역률개선 LC필터를 제거하고 출력캐패시터와 인버터 스위치의 정격축소를 통해서 재료비를 줄이기 위해서 적절한 설계절차를 제시하였다. 이렇게 결정된 소자를 사용하여 6[kW] 소지전력을 갖는 프로토형 회로를 구성하고 제안된 회로의 동작을 확인하기 위해서 실험을 하였다.

  • PDF