• 제목/요약/키워드: Air Conditioner Compressor

검색결과 165건 처리시간 0.028초

공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계 (The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner)

  • 홍용주;박성제;김효봉
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

자동차 에어컨 냉매 가스 누설에 대한 고장사례 고찰 (A Study of Failure Examples for Refrigerant Gas Leakage in Automotive Air Conditioner System)

  • 이일권;국창호;문학훈;유창배
    • 한국가스학회지
    • /
    • 제20권2호
    • /
    • pp.10-15
    • /
    • 2016
  • 이 논문의 목적은 자동차 에어컨 가스 누설에 관련된 고장사례를 분석하고 고찰한 것이다. 첫 번째 사례는 냉매가 누설된 상태에서 에어컨 컴프레서가 계속 작동되었다. 이로 인해 에어컨 컴프레서 내부의 피스톤이 윤활부족으로 인해 피스톤이 부분적으로 에어컨 컴프레서 내부의 실린더에 소착되는 현상이 발생하였다. 이것이 엔진작동 중 부하를 증대시켜 엔진의 회전수 변동과 함께 엔진의 작동이 정지되는 현상이 발생된 것으로 확인되었다. 두 번째 사례는 에어컨 라인과 관련 시스템을 확인한 결과 에어컨 컴프레서에서 뒤쪽으로 가는 컨덴서 고압파이프에서 미세한 균열에 의해 에어컨 냉매 가스가 누설되는 것을 확인하였다. 세 번째 사례는 에어컨 컨덴서 핀 부에서 육안으로 확인하기 어려운 미세한 크랙에 의해 컨덴서 내부 안쪽에서 에어컨 가스가 미세하게 누설되는 것을 확인하였다. 따라서, 에어컨 시스템은 에어컨 냉매가스에 의해 자동차의 실내의 온도를 낮춰 공기조화를 하는 시스템이므로 최적의 상태를 유지할 수 있도록 철저한 관리를 하도록 하여야 한다.

상용차를 위한 무시동 에어컨 압축기용 공진형 DC/DC 컨버터 개발 (Development of the Anti-Start Air Conditioner Compressor Resonant DC/DC Converter for Commercial Vehicle)

  • 한근우;김성곤;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.557-563
    • /
    • 2014
  • This study deals with a resonant converter of an anti-start air conditioner compressor for commercial vehicles. The anti-start air conditioner compressor must generally have a high current, high efficiency, a low volume, and a low weight. To reduce the switching losses and voltage and current stresses of the device, the anti-start air conditioner compressor applies the full-bridge L-C resonant converter topology. Hardware parameters are designed to have a wide voltage range, and the switching frequency range of the L-C resonant converter is determined. Simulation is implemented using PSIM and an experiment is performed to verify the proposed converter.

차량용 에어컨의 성능에 미치는 인자에 관한 연구 (Parametric Study on Performance of an Automobile Air Conditioner)

  • 박윤철;권기린
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.16-22
    • /
    • 2002
  • This study was conducted to find performance evaluation method for automobile air conditioner. Experimental facilities were constructed to simulate wide range of operating condition for the automobile air conditioner. Compressor speed was controled by variable speed electric motor and the power was measured through torque transducer and tachometer was used to measure compressor speed. Parametric studies were conducted in this study, to figure out effect of environment variables on the performance of the automobile air conditioner. The environmental variables are inlet air temperature, relative humidity and air flow rate for the evaporator and inlet air temperature and air flow rate for the condenser. Compressor speed is also changed. The results of this study shows that air flow rate of the evaporator is more sensitive to the performance of the automobile air conditioner than the other variables. However relative humidity of the inlet air of the evaporator strongly affects capacity rather that COP.

  • PDF

차량용 에어컨 컴프레서 브라켓의 형상최적화 (Shape Optimization of an Air-conditioner Compressor Mounting Bracket)

  • 제형호;김찬묵;강영규;이두호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.389-394
    • /
    • 2003
  • In this paper, a shape optimization technique is applied to design of an air-conditioner mounting bracket. The mounting bracket is a structural component of an engine, on which bolts attach an air-conditioner compressor. The air-conditioner mounting bracket has a large portion of weight among the engine components. To reduce weight of the bracket, the shape is optimized using a finite element software. The compressor assembly, composed of a compressor and a bracket is modeled using finite elements. An objective function for the shape optimization of the bracket is the weight of the bracket. Two design constraints on the bracket are the first resonant frequency of the compressor assembly and the fatigue life of the bracket. The design variables are the shape of the bracket including thickness profiles of the front and back surfaces of the bracket, radius of outer bolt-holes, and side edge profiles. The coordinates of the FE nodes control the shape parameters. Optimal shapes of the bracket are obtained by using SOL200 of MSC/NASTRAN.

  • PDF

Identification of Noise Sources in Scroll Compressor for Air-Conditioner

  • Lee, Jin-Kab
    • Journal of Mechanical Science and Technology
    • /
    • 제14권6호
    • /
    • pp.597-604
    • /
    • 2000
  • Low noise of air-conditioners is one of the most important issues because of the users' strong demand. The main source of noise in an air-conditioner is the compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in the air-conditioner field. Recently, scroll compressors are widely used, because they feature low noise, due to less pulsation of gas pressure, than that of rotary compressors. For reduction of noise, the source of noise must be identified. This paper presents a detailed analysis to identify the noise source and shows the dominant factors of noise of the scroll compressor, which will make it possible to design a scroll compressor with low noise.

  • PDF

전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템 (Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit)

  • 한근우;김성곤;이충훈;최명현;정영국;임영철
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

분리형 인버터 에어컨의 운전조건에 따른 성능 연구 (A study on the performance of a split system inverter air-conditioner at different operation conditions)

  • 김만회
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

공조용 밀폐형 압축기의 토출부 압력맥동 및 케비티 공명에 대한 연구 (Study on Pressure Pulsation and Cavity Resonance in Discharge Plenum of Hermetic Compressor)

  • 이진갑
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.302-308
    • /
    • 2000
  • The major source of noise in air-conditioner is a compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in air-conditioner field. Recently, a scroll compressor is widely used, because a scroll compressor features lower noise, due to less pulsation of gas pressure, than that of the rotary compressor. During a past noise reduction effort on a scroll compressor, noise radiation from the discharge portion of the hermetic shell was identified as the major contributor to overall noise. For a reduction of noise, the source of noise at the discharge portion must be identified. This paper presents detailed analyzes for the discharge pressure pulsation and cavity resonance at discharge space, which will make possible a low noise design of a scroll compressor.

  • PDF

저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구 (The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors)

  • 황윤제;조은준;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.