• 제목/요약/키워드: Air Coil

검색결과 330건 처리시간 0.023초

치과정밀주조에 활용되는 Air-Vent의 효과에 관한 연구 (A Study on The Effect of Air-Vent Utilized to Dental Precision Casting)

  • 김부섭
    • 대한치과기공학회지
    • /
    • 제16권1호
    • /
    • pp.5-11
    • /
    • 1994
  • On purpose of relative comparison of between air-vent attached pattern and non attached one, casting tests were accomplished by castability analysis unrig wax screen mesh pattern. Experimental specimens are divided Into 4groups. 1) Air-vent attached pattern with high casting pressure(coil spring type centrifugal casting machine 2.5turn). 2) Air-vent attached pattern with low casting pressure(coil spring type centrifugal casting machine 1.5turn). 3) Air vent non attached pattern with high casting pressure(coil spring type centrifugal casting machine 2.5turn). 4) Air-vent non attached pattern with low casting pressure(coil spring type centrifrgal casting machine 1.5turn). The main results are as follows : 1) The condition of high casting pressure no.1, no.3 were showed perfect castability. 2) The condition of low-casting pressure, there is a wide difference between no.2, no.4 group. Castability of no.2 group preferable to no.4 group(p<0.001). 3) Low casting pressure and complex shape cause the low-castability. So it is recommanded that use of air-vent in case of complex shaped wax pattern with low easting pressure.

  • PDF

경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers)

  • 손창효;오후규
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

Air-cored induction 코일 센서의 실험 기반 고주파 특성 모델링에 대한 연구 (Empirical Characterization of an Air-cored Induction Coil Sensor using Constructional Parameters)

  • 임한상;김인주
    • 전자공학회논문지SC
    • /
    • 제47권2호
    • /
    • pp.1-7
    • /
    • 2010
  • 본 논문은 Air-cored induction 코일 센서의 고주파 동작 특성에 대한 실험적 관계식을 제시한다. Air-cored induction 코일 센서는 입, 출력 간 선형성이 좋고 저주파 영역에서 정확한 출력 특성 예측이 가능해서 널리 사용되지만 민감도가 낮다는 단점이 있다. 반면, 고주파 영역에서는 코일 센서 구성상의 기생효과로 인해 민감도가 크게 향상되지만 인가되는 자기장 주파수에 대한 출력 민감도의 의존성으로 인해 사용이 제한되어 왔다. 그러나 최근 고정된 주파수의 자기장을 대상으로 하는 비파괴 자기 검사법에서 검사 성능을 향상시키기 위하여 이와 같은 코일 센서의 고주파 특성을 이용하기 시작하였는데 코일 센서를 고주파 영역에서 사용하기 위해서는 고주파 영역에서의 센서 특성에 대한 예측이 요구된다. 본 논문에서는 다양한 코일 센서의 구성 조건하에서 코일 센서의 주파수 응답 특성을 측정하고 이 측정 결과를 기반으로 하여, 민감도가 최대가 되는 공진 주파수와 최대 민감도를 코일 센서 단면의 지름, 권선 지름, 그리고 권선 수와 같은 구성 파라미터의 함수식으로 근사하였다. 함수식은 실험결과를 잘 반영하며, 추론된 함수식으로부터 원하는 사양을 가지는 코일 센서의 구성 방안 및 관련 회로 설계 사양을 얻을 수 있다.

환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가 (Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit)

  • 한창우;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.

무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작 (Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission)

  • 김성태;차두열;강민석;조세준;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.

풍력발전기 Air Guide 위치별 온도상승 해석 (Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator)

  • 한창우;김현재;권기영;이학성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

공심 코일형 리니어 DC 모터의 설계 및 동특성 해석 (Design and Dynamic Analysis of Air-core Coil type Linear DC Motor)

  • 강규홍;홍정표;김규탁;하근수;정중기;임태빈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.165-171
    • /
    • 2000
  • This paper proposes a technique to design of air-core type Linear DC Motor(LDM) by using Equivalent Magnetizing Current(EMC) method and has performed its dynamic analysis. The magnetic flux density differ in accordance with airgap position due to difference of mechanical and magnetic air gap length and the coil shape has an influence on the thrust. Therefore, the analysis of magnetic field due to the magnets is carried out by EMC. The phenomena according to the various coil various coil shape under the same Magneto Motive Force(MMF) has been analyzed and its result is applied to the design process. The appropriateness of the proposed technique is confirmed by Finite Element Method(FEM) and its dynamic analysis is carried out from the coupling of the electrical circuit equation and mechanical kinetic equation.

  • PDF

압입식 송풍방식을 적용한 AHU의 성능 향상을 위한 연구 (A Study on Performance Enhancement of AHU with a Pressure Type Fan)

  • 장호성;김은필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1164-1169
    • /
    • 2008
  • The miniaturization of the Air Handling Unit (AHU) has become an actual need because of the restriction of the using space on the vessel. In modern AHU’s construction, in which the fan section is at the end part of the ship, it’s very difficult to select a suitable capacity of evaporators, because the fan motor emits heat. Thus, the AHU structure has been changed as the fan section has been set before the cooling coil to get temperature values similar to the designed amount. Also, the air guider is installed in order to maintain equal air distribution after it passed the fan section. So, it is possible for air to equally pass the cooling coil. It is investigated three different geometries to find the best performance. Also, It is compared with the numerical and experimental results. The study found the case 3 gives the best results. The results of this study show the possible application of the new design.

밸브구동용 보이스 코일 선형 포스모터 설계와 해석 연구 (A Study on the Design and Analysis of a Voice Coil Linear Force Motor for Hydraulic Valve)

  • 박창순;허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.1-7
    • /
    • 2012
  • The voice coil linear force motor is a kind of a direct drive motion device that uses a permanent magnetic field and coil winding to produce force. In order to design a voice coil linear force motor, an exact calculations of the required force, the flux density in air gap and the flux pathway are needed. A conventional method can be used usually to calculate the flux density in air gap, but with this method it is needed to find a magnetic circuit revision constant. In this paper a voice coil linear force motor is designed by conventional design method and analyzed by 3D simulation program "Flux". For the prototype linear force motor, the results of the calculated by conventional design method and the analyzed by 3D simulation program are compared with the test result. Finally it is showed that the magnetic circuit revision constant which is found by comparing of the analyzed and the measured data can be used for the design of the voice coil type linear force motor to minimize the trial and error.