공기흡입에 의한 스크류식 원심펌프의 양수불능 특성에 관한 연구 (A Study on the Break-down Characteristics of a Screw-type Centrifugal Pump due to Air Entrainment)

  • 김유택
    • 한국유체기계학회 논문집
    • /
    • 제6권3호
    • /
    • pp.58-63
    • /
    • 2003
  • The performance of turbo pump drops rapidly and it gets into break-down when the void fraction reaches above the threshold value because the impeller flow passage is choked up with air bubbles. Phenomenological understanding of break-down and pumping recovery mechanisms under air-water two-phase flow conditions are therefore important for pump designers and essential assignment for researchers. In this paper, we investigated the characteristics of break-down and pumping recovery due to entrained air occurring inside a screw-type centrifugal pump which has a wide flow passage mainly through the findings of suction and discharge pressures, rotational speed, flow rate measurements and visualization.

합성곱 신경망을 이용한 컨포멀 코팅 PCB에 발생한 문제성 기포 검출 알고리즘 (A Problematic Bubble Detection Algorithm for Conformal Coated PCB Using Convolutional Neural Networks)

  • 이동희;조성령;정경훈;강동욱
    • 방송공학회논문지
    • /
    • 제26권4호
    • /
    • pp.409-418
    • /
    • 2021
  • 컨포멀 코팅은 PCB(Printed Circuit Board)를 보호하는 기술로 PCB의 고장을 최소화한다. 코팅의 결함은 PCB의 고장과 연결되기 때문에 성공적인 컨포멀 코팅 조건을 만족하기 위해서 코팅면에 기포가 발생했는지 검사한다. 본 논문에서는 영상 신호 처리를 적용하여 고위험군의 문제성 기포를 검출하는 알고리즘을 제안한다. 알고리즘은 문제성 기포의 후보를 구하는 단계와 후보를 검증하는 단계로 구성된다. 기포는 가시광 영상에서 나타나지 않지만, UV(Ultra Violet) 광원에서는 육안으로 구별이 가능하다. 특히, 문제성 기포의 중심은 밝기가 어둡고 테두리는 높은 밝기를 가진다. 이러한 밝기 특성을 논문에서는 협곡과 산맥 특징이라 부르고 두 가지 특징이 동시에 나타나는 영역을 문제성 기포의 후보라 하였다. 그러나 후보 중에는 기포가 아닌 후보가 존재할 수 있기 때문에 후보를 검증하는 단계가 필요하다. 후보 검증 단계에서는 합성곱 신경망 모델을 이용하였고, ResNet이 다른 모델과 비교하였을 때 성능이 가장 우수하였다. 본 논문에서 제시한 알고리즘은 정확률(Precision) 0.805, 재현율(Recall) 0.763, F1-점수(F1-score) 0.767의 성능을 보였고, 이러한 결과는 기포 검사 자동화에 대한 충분한 가능성을 보여준다.

Effects of Air Injections on the Resistance Reduction of a Semi-Planing Hull

  • Kim, Gyeong-Hwan;Kim, Hyo-chul
    • Journal of Hydrospace Technology
    • /
    • 제2권2호
    • /
    • pp.44-56
    • /
    • 1996
  • The effects of the air on the reductions in resistance when supplied under the bottom of a semi-planing ship with a step are investigated in the present study. A 1.275m long FRP model is constructed and the pressure and viscous tangential stresses over the planing surface of the hull with and without air supply are measured through measuring holes carefully selected at the towing tank of Seoul National University. Locations of holes most suitable for air injection are surveyed in front of the planing surface of the model with careful examinations of the limiting streamlines and pressure distributions measured without air supply. At those locations, found to be just front of the step, air has been supplied into a wake region to form an air filled cavity of fixed type. Flow rates and pressure of the supplied air as well as the local pressure and shear stress distributions on the hull surface are measured to understand the physics involved as well as to determine the conditions most effective in resistance reduction at the design speed. It has been found that total resistance of the stepped semi-planing hull can be considerably reduced if an air cavity generated by an adequate air injection at the bottom of the hull near the step. After the cavity optimized at the given speed, air bubbles also have been generated right behind the point where dividing streamlines re-attach to further reduce the frictional resistance but found to be not so effective as the air cavity in resistance reductions.

  • PDF

도로성토체로 사용된 실트질 계열의 경랑기포혼합토에 대한 물의 영향 (Effect of Water on the Lightweight Air-Mixed Soil Containing Silt Used for Road Embankment)

  • 황중호;안영균;김태형
    • 한국지반공학회논문집
    • /
    • 제26권2호
    • /
    • pp.23-32
    • /
    • 2010
  • 본 연구는 특별히 물과 관련된 실트질 계열의 경량기포혼합토(기포슬러리밀도 10kN/$m^3$ 대상)의 특성변화를 알아보기 위해 수행되었다. 일축압축강도, 투수계수, 모관상승고 등에 대한 연구가 이루어졌으며, 이들 연구를 뒷받침할 수 있는 경량기포혼합토의 미세구조에 대한 연구도 아울러 진행되었다. 사진을 통한 미세 구조 분석 결과 경량기포혼합토 내의 기포는 다양한 크기로 존재하며, 위치별 기포의 분포는 거의 일정한 것으로 밝혀졌다. 또한 기포 안에 아주 많은 미세한 공극들이 존재하여 물에 의해 경량기포혼합토가 포화상태에 가까이 도달될 수 있음이 밝혀졌다. 이미지를 이용한 간극률 산정도 같이 이루어졌다. 일축압축강도 시험 결과, 물에 의한 극한강도 값의 변화는 없으나 응력-변형거동에는 영향을 주는 것으로 나타났다. 경량기포혼합토의 투수계수는 평균 $4.857{\times}10^{-6}cm/sec$로 점토보다는 약간 큰 값을 갖는 것으로 나타났다. 경량기포혼합토의 모관상승은 시험초기부터 100분 이내에는 가파르게 진행되고, 그 이후 경과시간에 따라 상승속도가 점진적으로 완만하게 진행됨을 알 수 있다. 모관상승은 곧 재료의 단위중량 증가를 유발하므로 경량기포혼합토의 설계와 유지관리 시 각별한 주의가 요구된다.

영상분석기법 기반 기포유동장 해석을 위한 격자의 민감도 분석 (Sensitivity analysis of grid size for bubble flow field analysis using image analysis methods)

  • 김성중;장창래
    • 한국수자원학회논문집
    • /
    • 제57권8호
    • /
    • pp.549-559
    • /
    • 2024
  • 본 연구에서는 수중에서 방출되는 기포의 유동특성 분석 및 거동을 해석을 위해 이용하는 영상분석기법의 적용성을 검토하기 위하여 실내실험을 수행하고 기포유동장 해석을 위한 격자의 민감도 분석을 하였다. 실내실험 수로 내에 정지유체 상태에서 여러 개의 노즐을 이용하여 기포를 발생시켜 기포장벽을 만들고 유동특성을 검토함으로써 분석방법의 적절성과 해석격자의 민감도를 분석하였다. 수리실험을 통한 기포의 유동특성을 분석하기 위해 해석격자에 대한 기포의 평균투영면적의 비인 투영면적비, 해석영역의 중심부 수심과 총수심과의 비인 수심비 등 매개변수를 정의하고, 각각의 변수간의 관계를 파악하기 위하여 상관분석 및 회귀분석을 수행하였다. 8가지 수심비에 따른 기포투영면적, 기포상승속도와의 관계를 분석한 결과, 수심비가 증가할수록 압력의 영향으로 인해 수면으로 상승할수록 기포의 크기는 높은 상관성을 가지며 선형적으로 증가하였다. 영상분석기법 적용을 위한 8가지 해석격자의 크기별 민감도 영향에서 투영면적비(0.09~0.96)에 따른 격자크기에 대한 민감도는 크지 않은 것으로 확인되었다. 이러한 결과를 통해 영상분석기법이 기포의 유동특성을 관측할 수 있는 적절한 기법이 될 수 있을 것으로 판단된다.

The Effect of Aerated Oil Considering Live Oil Surface Tension on High-Speed Journal Bearing

  • Chun, Sang-Myung
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.103-113
    • /
    • 2001
  • The influence of aerated oil on high-speed journal bearing is examined by classical thermohydrodynamic lubrication theory coupled with analytical models for viscosity and density of air-oil mixture in fluid-film bearing. Convection to the walls and mixing with supply oil and re-circulating oil are considered. The live oil surface tension is considered as functions of temperature, API gravity and air volume ratio. With changing eccentricity ratio, it is investigated the effects of air bubbles on the performance of a high-speed plain journal bearing. Just at the moderate eccentricity ratios, even if the involved aeration levels are not so severe and the entrained air bubble sizes are not so small, it is found that the bearing load and friction farce may be changed so visibly for the high speed bearing operation.

  • PDF

경막외강 스테로이드 주입 시 발생한 기뇌증 -증례 보고- (Pneumocephalus after Epidural Steroid Injection -A case report-)

  • 정성규;박경희
    • The Korean Journal of Pain
    • /
    • 제14권2호
    • /
    • pp.276-279
    • /
    • 2001
  • Epidural steroid injection is one method of releiving chronic back pain. However, problems with the loss of resistance to air technique include the possible subarachnoid or subdural injection of air resulting in headache, venous air embolism, and the introduction of air bubbles into the epidural space. Pneumocephalus is a rare complication of epidural block for epidural steroid injection. We report a case of a 58-year-old woman who developed a severe headache and posterior nuchal pain with incomplete oculomotor palsy due to pneumocephalus occuring after an epidural steroid injection.

  • PDF

Air Bubbles Mimic Disc Herniation in MRI after Cervical Epidural Block

  • Kim, Tae-Sam;Shin, Sung-Sik;Kim, Jung-Ryul;Kim, Dal-Yong
    • The Korean Journal of Pain
    • /
    • 제23권3호
    • /
    • pp.202-206
    • /
    • 2010
  • Magnetic resonance image (MRI) is the most sensitive imaging test of the spine in routine clinical practice. Unlike conventional x-ray examinations and computed tomography scans, high-quality magnetic resonance images can be assured only if patients are able to remain perfectly still. However, some patients find it uncomfortable to remain still because of pain. In that condition, interlaminar cervical epidural injections can reduce pain and allow the procedure. When using air with the "loss of resistance" technique in epidural injections to identify the epidural space, there is the possibility of injected excessive air epidurally to mimic a herniated disc. We describe a case report of epidural air artifact in a cervical MRI after cervical epidural injections.

시판 통조림 어단의 조직화학적 관찰 (HISTOCHEMICAL OBSERVATION OF CANNED FISH BALL COLLECTED FROM THE LOCAL MARKET OF KOREA)

  • 최선남
    • 한국수산과학회지
    • /
    • 제8권3호
    • /
    • pp.166-170
    • /
    • 1975
  • 시판되고 있는 6종의 어단 통조림을 수집하며 조직화학적 방법으로 분석한 결과를 요약하면 다음과 같다. 1. 단백질 함량은 일반적으로 낮았으며 $2.7\~8.9\%$의 함량을 보였고, 지방은 시료에 따라서 매우 변화가 심한 $1.4\~17.6\%$이었다. 3. 탄수화물은 약 $58.1\~75.2\%$로서 가장 높은 함량을 보였다. 3. 공포는 $14.4\~21.1\%$ 로서 많은 편이었다. 4. $37^{\circ}C$에서 4일간 배양한 시료 어단에서는 주로 전분, 단백질 및 공포주위에서 미생물이 집락을 형성하고 있는 것이 관찰되었다. 3. 이상을 종합할 때 수산연제품의 일종인 통조림 어단의 품질은 조직화학적 및 형태학적 방법으로 충분히 평가할 수 있는 것으로 판단된다. 끝으로 본실험을 위하여 지도하여 주신 전북대학교 예방의학교실 이 재구 박사 및 실험을 도와 주신 동교실 김 수명씨에게 사의를 표하는 바이다.

  • PDF

양식장 배출수 수질관리를 위한 용존공기부상 공법의 운전 인자 영향 분석 (Analysis of the operating factors of dissolved air flotation (DAF) process for effluent quality improvement from aquaculture rearing tank)

  • 기재홍;김형준;이주영;한무영;강희웅
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.107-113
    • /
    • 2012
  • Pollutants in aquaculture system effluent mostly originated from solid wastes including uneaten feed and excreta of cultured species. In this research, DAF(Dissolved Air Flotation) unit is suggested as an integrated solid control unit especially as a form of IIBG(Inline Injection Bubble Generation) process in aquaculture system. Solid removal performance of DAF unit was examined under various operation and salinity conditions with turbidity and suspended solid. Solid waste removal efficiencies were found to be affected by operation conditions including saturator pressure, recycle ratio, coagulant concentration. Solid removal efficiency was higher under higher saturator pressure and recycle ratio under which condition larger number of bubbles is generated. Coagulant is thought to have important role in creating bubble-particle aggregate by showing better removal efficiency with higher concentration. However higher saline water showed less effectiveness in removing solids by DAF(IIBG). Application of DAF(IIBG) process also showed additional effect in phosphate removal and DO(Dissolved Oxygen) supply. Phosphate existed in polluted water was removed up to 46% after treatment, which is thought to attribute to aluminium phosphate precipitation. And DO concentration was found to increase over 50% of initial saturation concentration after the injection of micro-bubbles. Through experiments on solid removal from aquaculture effluent, DAF(IIBG) process is estimated to be effective solid control method. This property can help aquaculture system being installed and operated simply and effectively.