Effect of Boundary Condition on the Flow Rate of the Internal Coolant in Gas Turbine Blades (경계조건에 따른 가스터빈 블레이드 냉각공기 유량변화)

  • 신지영;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.888-894
    • /
    • 2001
  • Advanced gas turbine engines employ turbine entry temperatures so high that cooling of the turbine blades is essential. The coolant flow introduces losses which need to be minimized, and therefore it is important that the minimum amount of coolant should be used. This work presents the result of the one-dimensional analysis and the effect of the boundary conditions on coolant flow rate in gas turbine blades.

  • PDF

A Study on Hydraulic Behavior and Mass Transfer by Absorption in Packing Tower (충전탑에서 흡수에 따른 물질전달과 수력학적 거동에 관한 연구)

  • 김석택
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.393-396
    • /
    • 2000
  • Packing tower has been used in the chemical industry and the protection of environment for a long time. In the view of environmental protection purification of exhaust gas can be performance effective by gas absorption in counter-current packing tower. In this study characteristics of hydraulic and mass transfer were investigated in D. $0.3m {\times} H. 1.4m$ packing tower with 50mn plastic Hiflow-ring. This study was carried out "Test systems were experimented in conditions of Air, $Air/H_2O. NH_3-Air/H_2O, NH_3-Air/H_2O-H_2SO_4$ and $SO_2-Air/H_2O-NaOH$ under steady state" The extent of test included dry and wetting pressure drop physical law separation efficiency and hold-up as function of gas and liquid load.quid load.

  • PDF

Combustion Characteristics of RDF in a 30kg/hr Scale Pyrolysis Melting Incinerator (30kg/hr급 열분해 용융소각로용 연소실에서 RDF의 연소 특성)

  • Jeon, Byoung-Il;Park, Sang-Uk;Shin, Dong-Hun;Ryu, Tae-Woo;Hwang, Jung-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.1
    • /
    • pp.27-36
    • /
    • 2005
  • In this study, we investigated characteristics of a gas flow and a combustion property during the combustion of a RDF in a pyrolysis melting incinerator with disposal rate of 30 kg/hr. The RDF was pyrolyzed through the pyrolysis chamber at $600^{\circ}C$ of the chamber surface without oxygen condition. The pyrolysis gas was injected in the combustion chamber. It was burned by means of the staged combustion that was injecting secondary and tertiary air in the combustor. We measured the temperatures and the gas components in the combustion chamber while maintaining the air-fuel ratio of 1.3. Finally, we confirm that additional air injection, secondary and tertiary air ratio, was the most important factor to reduce NOx.

  • PDF

Experimental Study of the Relationship between Weight Variation and Thermal Conductivity in Polyurethane Foam (단열재의 무게변화와 열전도도와의 상관관계에 관한 실험적 연구)

  • Lee, Hyo-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.241-246
    • /
    • 2015
  • Cellular foamed insulation such as polyurethane foam ages and degrades the thermal conductivity. Aging of foam is a result from the diffusion of gases, initially consisting of $CO_2$ but eventually replaced by air from the environment. The variation of the cell gas content with time is primarily influenced by the increase of thermal conductivity of the cellular foam. The weight of foam also changes as the gas diffuses and exchanges. In this study, a weight measurement method has been proposed to evaluate the effective diffusion coefficients of $CO_2$ and Air, $D_{CO2}=7.08504E-11$ and $D_{air}=4.86086E-12$, respectively and are compared with the gas analysis method.

Discussions on the Leak Phenomena of Liquid Butane in the Open Air (액화석유가스(butane)의 대기중 누출현상에 대한 고찰)

  • Yoon, Jae-Kun
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2000
  • Almost accidents related with gas have started with the leakage of LPG(Liquefied Petroleum Gas) in the open air. But experimental data of LPG leak jet are difficult to find because the safety of experiment is hard to secure and its phenomenon is not steady but transitional. This study is focused on the phenomena of injection jet of liquid butane to the open air. Simple experiment shows that only liquid butane jet in the open air is possible due to the slow vaporization because of low temperature difference between the liquid and air and low vapor pressure of liquid butane. Comparing with the water, 25~40% more liquid butane flow through the tube under the same pressure difference driving.

  • PDF

Prediction of Oxygen Transfer Rate During Sisomicin Fermentation Employing Air Lift Fermentor (Air Lift Fermentor에서 Sisomicin 발효시에 발효유사액을 이용한 산소전달속도 예측)

  • 김성룡;신철수
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.6
    • /
    • pp.659-664
    • /
    • 1994
  • In order to predict gas hold-up and oxygen transfer rate during sisomicin fermentation employing air lift fermentor, simulated media similar to fermentation broths in rheological proper- ties were prepared and used. Rheological properties of fermentation broths from 40 hours and 60 hours of cultivation were analyzed by applying to Power's Law equation. Regardless of addition and no addition of MgSO$_{4}$, the tendencies, that n value was decreased and K value was increased as aeration rate was increased, were shown. Simulated media of twelve different fermentation broths were formulated in a range of 0.7 to 2.1% CMC, and the values of gas hold-up and k$_{L}$a depending on superficial air velocity were measured using these simulated media. And the relation- ships, $\varepsilon$=$\alpha$U$_{Gr}$$\beta$, K$_{L}$a=$\gamma$U$_{Gr}$$\delta$ were obtained, and these equations are thought to be used to predict the values of gas hold-up and k$_{L}$a during fermentation.

  • PDF

Preliminary Design Program Development for Aircraft Gas Turbine Combustors : Part 2 - Air Flow Distribution (항공용 가스터빈 연소기 기본 설계 프로그램 개발 : Part 2 - 공기 유량 배분)

  • Kim, Daesik;Ryu, Gyong Won;Hwang, Ki Young;Min, Seong Ki
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.3
    • /
    • pp.61-67
    • /
    • 2013
  • This study introduces the design methods for air flow distribution at the level of preliminary design, and reviews the typical combustion process and main functions of sub-components of aircraft gas turbine combustors. There are lots of design approaches and empirical equations introduced for air flow distributions at the combustors. It is shown that a decision on which design approaches work for the combustor development is totally dependent upon the objective of engine design, target performance, and so on. The current results suggested for preliminary air flow distributions need to be validated by combustor geometry checkups and performance evaluations for future works.

Stabilization of Fuel F1ow in a Multi-Nozzle Combustion System Burning Natural Gas (천연가스 다노즐 열원설비의 연료 유동 안정화)

  • 박의철;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1255-1265
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient flow in a utility gas turbine burning natural gas. The solution domain encompasses the supply gas pressure regulator to the combustor of the gas turbine that employs multi-nozzle fuel injectors. Some results produced for verification in the present study agree suite well with the experimental ones. It is found that the total gas flow may decrease noticeably during its combustion mode change, which would be the reason of momentary combustion upset, when a reference case of opening ratios of control valves in the system is applied. Several parameters are then varied in order to make the total gas flow stable over that period of time. Results of this study may be useful to understand the unsteady behavior of combustion system burning natural gas.

  • PDF

A Numerical Study on Flow around Exhaust Ducts of Flue Gas from Apartment Heating Boiler (공동주택 보일러 연소배기가스의 실내유입에 관한 수치적 연구)

  • 박외철;정락기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.557-562
    • /
    • 2003
  • Flue gas from apartment heating gas boiler is exhausted outside through an exhaust duct mounted horizontally in a vertical row on the wall. The flue gas includes nitrogen-oxides (NOx) and carbon monoxide. To investigate the possible entrainment of the flue gas into the apartments through the windows, a large eddy simulation (LES) based numerical method is utilized. Distribution of the velocity intensity and temperature around the exhaust ducts is presented for three numerical parameters: exhaust velocity, temperature of the flue gas, and exhaust duct length. The flow field visualized with particles inserted at the ends of the ducts is also presented. The results clearly show that the exhausted flue gas may flow into the apartments when the windows are open.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF