• Title/Summary/Keyword: Aggregate Ratio

Search Result 1,118, Processing Time 0.038 seconds

Engineering Properties of No-fines Concrete (No-fines Concrete의 공학적 특성)

  • 민정기;성찬용;김성완
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • This study was carried out to investigate the engineering properties of no-fines con- crete, consisting only of coarse aggregate, cement and water. The used coarse aggregates were two, one is natural coarse aggregate grading 4.75~ lOmm, the other is synthetic lightweight coarse aggregate grading 3~8mm. The results of this study are summarized as follows; 1. The W/C ratio of each type was increased with increase of additional amount of coarse aggregate. 2. The unit weight of used ndtural coarse aggregate was shown 1.762~2.184g/cm$^3$, and synthetic lightweight coarse aggregate was shown 0.756 ~ 1 .348g/cm$^3$. 3. The ahsorption rate of used natural coarse aggregate was shown 8.4 ~ 9.4 %, and synthetic lightweight coarse aggregate was shown 17.0~42.4%. 4. The compressive, tensile and hending strength was decreased with increase of coarse aggregate, respectively. The compressive strength of natural coarse aggregate 1:3 was shown 309kg/cm$^2$. 5. The ultrasonic pulse velocity and dynamic medulus of elasticity of each type was de- creased with increase coarse aggregate, respectively. Also, the decreasing rate of the natural aggregate was larger than that of the synthetic lightweight coarse ag- gregate.

  • PDF

Bond Strength Characteristics Between Aggregate and Mortar (골재-모르타르 경계면의 부착강도 특성)

  • 박연동;양주경;임희철;김진근;장정수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.129-134
    • /
    • 1991
  • The effects of water-cement ratio, age, and admixture such as fly ash, silica fume on the bond strength between aggregate and mortar were investigated. As the result, with increasing of water-cement ratio, the bond strength was slightly decreased while the compressive strengths of mortar and concrete were seriously decreased. The rate of strength gain of bond strength was not decreased with increasing of water-cement ratio while that of compressive strength was gradually decreased.

  • PDF

Application of Waste Foundry Sand to Concrete-Based Product Having Low Water Cement Ratio (낮은 W/C비를 갖는 콘크리트 제품에 대한 폐주물사의 적용)

  • 이대경;김동주;조홍준;김진만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.79-84
    • /
    • 2001
  • Because the WFS(Waste Foundry Sand), by-product of a casting factory, is generally a smaller particle than a fine aggregate, it has a bad influence on quality of concrete. Especially, the grading of aggregate is a very important factor in the case of concrete-based products having low water cement ratio manufactured by vibration and pressing method. Therefore, it is necessary to use WFS with the suitable grading of aggregate that it don't has a bad Influence on the quality of concrete-based products. This study investigated the suitable using proportion of WFS by means of the composition method of aggregate suggested by Driscoll. The results showed that it was desirable to use 10% of WFS since higher strength was developed with that amount.

  • PDF

An Experimental Study on the Evaluation of Porous Concrete using Industrial By-products of Planting Factory (산업부산물을 이용한 포러스콘크리트의 식생능력평가에 관한 연구)

  • 박승범;권혁준;서대석;윤덕열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.779-784
    • /
    • 2002
  • Porous concrete with a great deal of continuous porosity enables to contain water and to pass air freely through firmly hardened material, and allow necessary nutrients to reach roots of vegetation. Therefore, this paper deals with the voluntary properties and efficiency for planting of plant porous concrete. The results of experiment showed that void volumes were 17% to 31%, and compressive strength ranged between 80kgf/cm$^2$ and 180kgf/cm$^2$ when the ratio of the paste to aggregate was 0.3-0.5 When the aggregate size are 20-30mm, the paste to aggregate ratio is 0.3, and the length of Paranial Ryegress came up as 32cm. Ut supra the efficiency of planting goes through Paranial Ryegrass in result the length of plant are in compliance with void volume and aggregate size.

  • PDF

Engineering Properties of Permeable Polymer Concrete Using Bottom Ash and Recycled Coarse Aggregate

  • Sung, Chan-Yong;Kim, Jong-Hyouk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.7
    • /
    • pp.25-31
    • /
    • 2006
  • Permeable polymer concretes can be applied to roads, sidewalks, river embankment, drain pipes, conduits, retaining walls, yards, parking lots, plazas, interlocking blocks, etc. This study was to explore a possibility of using bottom ash as filler and recycled coarse aggregate of industrial by-products for permeable polymer concrete. The tests carried out at $20{\pm}1^{\circ}C$ and $60{\pm}2%$ relative humidity. At 7 days of curing, unit weight, void ratio, compressive and flexural strength and coefficient of permeability ranged between $1,652{\sim}1,828kgf/m^{3},\;15{\sim}29+%,\;18.2{\sim}24.5\;MPa,\;6.4{\sim}8.4\;MPa\;and\;6.8{\times}10^{-2}{\sim}1.7{\times}10^{-1}\;cm/s$, respectively. It was concluded that the bottom ash and recycled coarse .aggregate can be used in the permeable polymer concrete.

Fresh and hardened properties of concrete containing cold bonded aggregates

  • Thomas, Job;B., Harilal
    • Advances in concrete construction
    • /
    • v.2 no.2
    • /
    • pp.77-89
    • /
    • 2014
  • The properties of fresh and hardened concrete made using three types of artificial cold bonded aggregates are determined. The properties, namely, slump, water absorption, compressive strength and splitting tensile strength of concrete containing artificial aggregate are reported. The variables considered are aggregate type and water-to-cement ratio. Three types of cold bonded aggregates are prepared using fly ash and quarry dust. The water-to-cement ratio of 0.35, 0.45, 0.55 and 0.65 is used. The test result indicates that artificial aggregates can be recommended for making the concrete up to a strength grade of 38 MPa. The use of quarry dust in the production of artificial aggregate mitigates environmental concerns on disposal problems of the dust. Hence, the alternate material proposed in this study is a green technology in concrete production.

Influence of Theoretical Void Ratio, Grading of Aggregate and Curing Method on Strength and Water Permeability of Porous Concrete (이론공극율, 골재입도 및 양생방법이 포러스콘크리트의 강도 및 투수성능에 미치는 영향)

  • 김재환;유범재;최세진;백용관;박정호;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.373-378
    • /
    • 2000
  • The objective of this study was to investigate the influence the influence of theoretical void ratio(T.V.R), grading of aggregate and curing method on the strength and water permeability of porous concrete, and the reduction proportion of water permeability by these factors. The results of the study showed that its strength and water permeability were greatly depended on the T.V.R and grading of aggregate, but didn't on the curing method. And, when the T.V.R and grading of aggregate were increased, the reduction proportion of water permeability was small. As the relation ship between its physical properties and non-destruction test values was very high, its use for the estimation of the physical properties will be useful.

  • PDF

Flowing and Strength Properties of Low Carbon Inorganic Composite Depending to Fine Aggregate Types and Replacement Ratio (잔골재 종류 및 치환율에 따른 저탄소 무기결합재의 유동 및 강도특성)

  • Park, Jong-Pil;Bae, Sang-Woo;Lee, Yun-Seong;Lee, Kang-Pil;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.235-236
    • /
    • 2011
  • This study analyzed flowing and strength properties of mortar depending to fine aggregate types and replacement ratio by using blast furnace slag, red mud, and silica fume that are industrial by products. The findings showed that higher replacement level of fine aggregate increased air content while decreased table flow. In addition, compressive strength showed that the higher replacement level was regardless of fine aggregate types, the lower strength became. Mortar substituted by the dredged sand showed high strength.

  • PDF

A Fundamental Study on the Properties of Lightweight Mortar Mixed with Bottom ash and Waste Foundry Sand (괴상석탄재와 폐주물사를 혼입한 경량모르터의 특성에 관한 기초적 연구)

  • 이승한;한형섭;정용욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.223-228
    • /
    • 1997
  • In this study, bottom ash, lightweight aggregate, and Expanded Polystyrene was used to lighten the mortar. In order to compensate the reduction of strength caused by lightening, the waste foundry sand produced as solid waste was substituted for fine aggregate. As the device of reducing the ratio of absorption, the procedure of mixture was altered to check the effectiveness of surface coating of porous lightweight aggregate. It was observed over 170kg/$\textrm{cm}^2$ compressive strength at gravity about 1.3, an over 380kg/$\textrm{cm}^2$ at gravity about 1.7. the maximum strength was occurred when 30% of fine aggregate was replaced was replaced with waste foundry sand, and the ratio of absorption was decreased over 10% by changing the procedure of mixture.

  • PDF

Strength Characteristics of Concrete Containing Blast-Funrnace Slag as Coarse Aggregate (고로슬래그를 굵은골재로 이용한 콘크리트의 강도특성)

  • 한상호
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.59-68
    • /
    • 2000
  • A series of experiments were performed to investigate the strength characteristics of concrete which contain air cooled blast-furnace slag as coarse aggregate. The slag is a by product of GISC. The experimental conditions are varied with three different W/C(45%, 50%, 55%) and the weight of water and S/a are constant. The strength properties of the concrete at 7days, 28days, 90days are examined. Also the same strength properties are examined for the normal concrete which contain river gravel and crushed stone respectively as coarse aggregate. As the comparison results of the strength properties, it was found that the compressive strength development of concrete containing blast-furnace slag is better than that of concrete using river gravel at early age, however this is adversely at long-term age, and the tensile and flexural strength of the concrete were not nearly affected by water-cement ratio.