• 제목/요약/키워드: Ag/AgCl

검색결과 530건 처리시간 0.025초

Electrochemical Deposition Characteristics of Ca2+ on Cu Wire Electrode in CaCl2 Molten Salt (CaCl2 용융염에서 Ca2+의 Cu 전극에 대한 전기화학적 증착 특성평가)

  • Hwang, Dong Wook;Lee, Jong Hyeon;Jeong, Sang Mun
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.175-183
    • /
    • 2022
  • With the expansion of the automobile market, the demand for Nd as an essential rare earth material for automobile motors is rapidly increasing. Research on the calcio-thermic reduction process between Nd2O3 and calcium-based alloys has been extensively studied in order to manufacture Nd. In this study, Ca-Cu, as a reducing for Nd2O3, was prepared by electrolysis in CaCl2 molten salt. Cu wire and graphite were employed as a working electrode and a counter electrode for electrolysis reaction, respectively. The reference electrode was manufactured by putting Ag wire in a mixture of AgCl and CaCl2 at a ratio of 1:99 mol%. The cyclic voltammetry results showed that the deposition of Ca2+ on the surface of working electrode was observed from a potential of -1.8 V, and the reduction potential of Ca2+ decreased as the reaction temperature increased. The diffusion coefficient of Ca2+ calculated by the chronoamperometry experiment was found to be 5.4(±6.8)×10-6 cm2/s. In addition, Ca-Cu liquid alloy was prepared by applying a constant potential to Cu electrodes. The element ratio of Ca-Cu alloy formed by applying a potential of -2.0 V was found to Ca:Cu=1:4.

Electrochemical Properties of Langmuir-Blodgett(LB) Monolayer Films of Alkyl Bromides Mixture (브롬화 알킬혼합물 단분자 LB막의 전기화학적 특징)

  • Son, Tae-Chul;Kim, Duck-Sool;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • 제27권2호
    • /
    • pp.202-207
    • /
    • 2010
  • We investigated the electrochemical properties for Langmuir-Blodgett(LB) films mixed with l-bromotetradecane(Cl4), l-bromohexadecane(Cl6), and l-bromooctadecane(Cl8). The alkyl bromides mixture was deposited by using the Langmuir-Blodgett method on the ITO glass. The electrochemical properties measured by using cyclic voltammetry with a three-electrode system(an Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode) at various concentrations(0.5, 1.0, 1.5 and 2.0 N) of $NaClO_4$ solution. A measuring range was reduced from initial potential to -1350 m V, continuously oxidized to 1650 mV. The scan rate was 100 mV/s. As a result, LB films of Cl4, Cl6, and Cl8 mixture monolayers appeared irreversible process caused by only the oxidation current from the cyclic voltammogram. The diffusivity(D) effect of LB films decreased with increasing of alkyl bromides amount.

Determination of Estrone by Adsorptive Stripping Voltammetry (흡착 벗김 전압전류법에 의한 에스트론의 정량)

  • Hong, Taekee;Kyong, Jin Burm;Lee, Hyun Jung;Czae, Myung-Zoon
    • Analytical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.34-39
    • /
    • 1999
  • Estrone such as estriol and estradiol can not be determined by votammetric methods, because these are electrochemically inactive in the potential windows for mercury drop electrode. Nitro-derivatives of estrone are electro active and nitration of estrone is accomplished by heating the solution involving estrone and sodium nitrite in a water-bath at $100^{\circ}C$ for 30 min. Such nitro-derivatives are determined directly by voltammetry. The electrochemical behavior for nitrated estrone was investigated by cyclic voltammetry. The trace estrone was determinated by differential pulse adsorptive cathodic stripping voltammetry. Nitrated estrone gives a well defined voltammetric wave at ca. - 0.61 V (vs. Ag/AgCl electrode). The electrochemical reaction was irreversible process in sodium borate buffer at pH 11 and nitrated estrone was strongly adsorbed on the surface of mercury electrode. The optimal experimental conditions for the determination of nitrated esterone were found to be 0.05 M sodium nitrate, 0.01 M sodium borate, pH 11.0, and an accumlation potential of 0.10 V (vs. Ag/AgCl). The detection limit was as low as $1{\times}10^{-9}M$ for estrone with 2 min accumulation time.

  • PDF

Analytical Studies of $H_2O_2$-Producing Oxidase Systems ($H_2O_2$-생성 산화효소계에 관한 분석 연구)

  • Younghee Hahn;Hae-Lim Cho
    • Journal of the Korean Chemical Society
    • /
    • 제37권10호
    • /
    • pp.874-880
    • /
    • 1993
  • Spectrophotometric enzymatic analysis and amperometric enzymatic analysis for the determinations of glucose and ethanol were studied utilizing glucose oxidase (GO) and alcohol oxidase (AO), respectively, which commonly consume $O_2$ and produce $H_2O_2$. For the determination of glucose, $H_2O_2$ were coupled to $K_4Fe(CN)_6$ via peroxidase producing $K_3Fe(CN)_6$ whose absorbance was measured at 418 nm or whose diffusion current was measured on the glassy carbon electrode at an applied potential of -55 mV vs. Ag/AgCl (sat. KCl) reference electrode. Amperometric analysis was 1000 times more sensitive as well as 10 times better in the linear concentration range than spectrophotometric analysis. For the determination of ethanol, AO only was used for the enzymatic analysis, since $K_3Fe(CN)_6$ was completely disappeared as soon as AO was added. Either rate of $H_2O_2$ produced was amperometrically measured at +0.900 V or rate of $O_2$ consumed was measured at -0.500 V vs. Ag/AgCl(sat. KCl) reference electrode.

  • PDF

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Synthesis of a New Cathode Redox Polymer for High Performance in Biofuel Cells

  • Choi, Young-Bong;Lee, Jung-Min;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2803-2808
    • /
    • 2014
  • High potential and fast electron transfer of a cathode mediator are significant factors for improving the performance of biofuel cells. This paper reports the first synthesis of a cathode redox polymer that is a coordination complex of poly (acrylic acid-vinylpyridine-acryl amide) (PAA-PVP-PAA) and [Os(4,4'-dicarboxylic acid-2,2'-bipyridine)$_2Cl_2]^{/+}$ ($E^{\circ}=0.48V$ versus Ag/AgCl). Bilirubin oxidase can be easily incorporated into this polymer matrix, which carried out the four-electron oxygen under typical physiological conditions (pH 7.2, 0.14 M NaCl, and $37^{\circ}C$). This new polymer showed an approximately 0.1 V higher redox potential than existing cathode mediators such as PAA-PVI-$[Os(dCl-bpy)_2Cl]^{+/2+}$. In addition, we suggest increasing the polymer solubility with two hydrophilic groups present in the polymer skeleton to further improve fast electron transfer within the active sites of the enzyme. The maximum power density achieved was 60% higher than that of PAA-PVI-$[Os(dCl-bpy)_2Cl]^{+/2+}$. Furthermore, high current density and electrode stability were confirmed for this osmium polymer, which makes it a promising candidate for high-efficiency biofuel cells.

Rapid Quantification of Chloride in Tobacco Leaves by a Chloride Meter (Model: CL-2Z) (Chloride Meter(CL-2Z형)를 이용한 담배잎 중 chloride의 신속한 검정방법)

  • Lee, Mee-Kyoung;Jeong, Hun-Chae;Kim, Yong-Yeon;Yu, Yun-Hyun
    • Journal of the Korean Society of Tobacco Science
    • /
    • 제28권2호
    • /
    • pp.83-93
    • /
    • 2006
  • The aim of this study is to develop a simple and rapid field method for the determination of chloride content in tobacco green or cured leaves. To set up a practical process, several factors such as the proper sampling position of each leaf, the size of leaf lamina pieces for blending, the substitution of deionized water fur the extracting solution, 0.1N $HNO_3$, the submerging durations before blending, and the standing times before measuring were studied using flue-cured and burley tobacco with a stable and reproducible Chloride Meter, KRK CL-2Z. From the results, chloride contents of tobacco leaves could be analyzed with the Chloride Meter(CL-2Z) using the suspension of 14 mm diameter leaf disks after soaking in distilled water for 30 min., blending with a mini-blender for 30 seconds. The chloride contents measured in this way showed highly significant correlations with ones by the conventional potentiometric method using an ion meter-chloride electrode and $AgNO_3$ titration. In our method, the procedures such as drying, powdering and weighing samples, and using chemical reagents for extraction (0.1N $HNO_3$) and titration(0.028N $AgNO_3$) could be eliminated. These results suggest that the newly constructed method using the Chloride Meter is more efficient to determine the chloride content of tobacco leave in comparison with the one by the Ion $Meter:AgNO_3$ titration.

Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

  • Chiba, Atsushi;Kusayanagi, Yukiharu
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.19-22
    • /
    • 2005
  • Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_2S$. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_{2}S$. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing $Na_{2}S$.

Protective Metal Oxide Coatings on Zinc-sulfide-based Phosphors and their Cathodoluminescence Properties

  • Oh, Sung-Il;Lee, Hyo-Sung;Kim, Kwang-Bok;Kang, Jun-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3723-3729
    • /
    • 2010
  • We investigated the high-excitation voltage cathodoluminescence (CL) performance of blue light-emitting (ZnS:Ag,Al,Cl) and green light-emitting (ZnS:Cu,Al) phosphors coated with metal oxides ($SiO_2$, $Al_2O_3$, and MgO). Hydrolysis of the metal oxide precursors tetraethoxysilane, aluminum isopropoxide, and magnesium nitrate, with subsequent heat annealing at $400^{\circ}C$, produced $SiO_2$ nanoparticles, an $Al_2O_3$ thin film, and MgO scale-type film, respectively, on the surface of the phosphors. Effects of the phosphor surface coatings on CL intensities and aging behavior of the phosphors were assessed using an accelerating voltage of 12 kV. The MgO thick film coverage exhibited less reduction in initial CL intensity and was most effective in improving aging degradation. Phosphors treated with a low concentration of magnesium nitrate maintained their initial CL intensities without aging degradation for 2000 s. In contrast, the $SiO_2$ and the $Al_2O_3$ coverages were ineffective in improving aging degradation.