• Title/Summary/Keyword: After-treatment device

Search Result 525, Processing Time 0.013 seconds

Development of Neuromuscular Stimulus System using Wearable Ultra-miniature Lighting Modules and its Verification of Clinical Effectiveness (의복형 초소형 발광모듈을 이용한 신경근육 자극 시스템 개발 및 임상적 효과 검증)

  • Park, Se-Hyeong;Lee, Jong-Shill;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.23-33
    • /
    • 2009
  • It can be used easily to reduce rehabilitation and treatment time if diagnostic and therapeutic devices are attached to cloth or body. Therefore we developed neuromuscular wearable ultra-miniature lighting modules which can improve the neuromuscular function and verified its clinical effectiveness. The system is based on the ultra-miniature lighting treatment module and there are two types of systems. One of them is designed as an attached type and the other type is combined with clothing. The wearable ultra-miniature lighting module is composed of controller (battery, MCU, bidirectional transmitter and receiver), cable, treatment medium generating device and other peripheral devices. To verify the clinical effectiveness of this device, we observed the difference of the strength of a muscle before and after 650nm and 25mW laser irradiation on the reflex point for 1 to 4 seconds. Among 48 patients having the degenerative osteoarthritis, the muscle strength before and after irradiation of laser was $21.8{\pm}7.99$ and $27.3{\pm}8.43$. According to the result, the muscle strength after treatment was significantly increased (p<0.01). To whom having difficulty in visiting to OPD(Out-Patient Department), doctors medically examine the patients and find the therapeutic point, attachment of this wearable ultra-miniature lighting module can function as self treatment (treating instrument) and treatment assist at home. If doctor can remotely control the patient and take part in treatment, the therapeutic device could contribute to prevention and care device.

Roller Design of IRB Seismic Isolation Device Using Test Evaluation : Part II. Heat Treatment of Material (시험평가법을 이용한 IRB 면진장치 롤러 설계 : Part 2. 소재 열처리)

  • Park, Young-Gee;Ha, Sung Hoon;Seong, Min-Sang;Jeon, Junchul;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.332-337
    • /
    • 2013
  • This paper presents a subsequent research work on the roller design of IRB(isolation roller bearing) seismic isolation device presented in Part 1 by focusing on heat treatment. The hardness and friction factor are very important factors of material and after-treatment process selection. Normally, roller bearing consists of roller and retainer. The roller gets high pressure constantly, while the retainer gets tensile and compressive stress. Therefore, sensitive material selection and heat treatment of each part is quite important. In this experimental evaluation, carbon steel, chrome special steel and others are employed and their characteristics after heat treatment are identified. Each material is prepared by refining high frequency heat treatment. The friction factor and static load capacity of manufactured material are experimentally identified and destructive test of material is processed. Optimal material and heat treatment conditions for IRB roller bearing are determined based on experiment results.

Design of 850 nm Near Infrared and Galvanic Current Based Eyeglass-Type Device for Periorbital Wrinkle Treatment and Verification of Treatment Performance through Image Analysis (850 nm 파장대 근적외선과 갈바닉 전류기반의 눈가 주름 치료기 개발 및 영상 분석을 통한 치료성능 검증)

  • Ahn, Sung Su;Kwon, Ki Jin
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.12
    • /
    • pp.1379-1386
    • /
    • 2018
  • In this paper, we proposed eyeglass type periorbital wrinkle treatment device for reducing and improving periorbital wrinkles using near infrared LED of 850nm wavelength and galvanic current. The proposed periorbital wrinkle treatment device is equipped with a control system based on F-PCB. It consists of eight near-infrared LEDs and four indicator LEDs for treatment of right and left periorbital wrinkles. The eyeglass frame is coated with conductive material, so galvanic current can flow to the skin of periorbital wrinkle contacted to it. One male adult in the mid-40s was allowed to use the device for 10 minutes every day for 4 weeks. After 4 weeks, image analysis using optical equipment for measuring wrinkles indicated that wrinkle indexes were reduced.

Hemolysis after PDA Unbrella Occlusion; Surgical Treatment (경피적 카테타 동매관 폐쇄술후 발생한 용혈)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.26 no.11
    • /
    • pp.890-893
    • /
    • 1993
  • The first successful percutaneous transcatheter occlusion technique for patent ductus arteriosus achived by Rashkind in 1977.Transcatheter occlusion with the Rashikind double umbrella device is now widely accepted as treatment for patent ductus arterisus. The reported complications include embolization of the device, psudocoarctation left pulmonary artery stenosis, residual shunts, and mechanical hemolysis. We report two cases of severe hemolysis after occlusion of PDA with Rashkind occluder.

  • PDF

The Short Term Effects of the Decompression (KNX $7000^{(R)}$) and Traction Device on Pain in Patients with Chronic Low Back Pain with or without Radicular Pain (만성 요통 및 하지방사통 환자에서 감압치료(KNX $7000^{(R)}$)와 견인치료의 단기 치료 효과)

  • Park, So-Hyun;Kim, Chul-Seoung;Lee, Dong-Gyu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.5
    • /
    • pp.29-34
    • /
    • 2011
  • Purpose: The purpose of this study is to evaluate the short term effects of the traction and decompression device, which is a newly developed domestic medical device, on pain and functional activity in patients with chronic low back pain with or without radicular pain. Methods: Forty patients with chronic low back pain were included and allocated to decompression (n=20) and traction groups (n=20). They received decompression or traction therapy for 20 minutes a day, 3 days per week for two weeks. For evaluating pain and functional activity, a visual analogue scale (VAS) for low back pain and the Oswestry back pain disability index (ODI) were obtained on pre-treatment, and at 6, 12 and 15 days after treatment. Patients'satisfaction levels were measured 15 days after treatment. Results: VAS was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in both groups (p<0.05). ODI was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in the decompression group (p<0.05). However, there was no significant difference between the two groups in the VAS and ODI scales (p>0.05). Patients' satisfaction levels were significantly higher in the decompression group than in the traction group (p<0.05). Conclusion: These findings suggest that decompression therapy might be effective for increasing functional activity in patients with low back pain and could provide patients with higher satisfaction than traction therapy. This study provided validity data for the therapeutic effects of the decompression device in patients with low back pain and it will be useful for medical cost development and patient education of this device.

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;JEONG, Tae-Hwan;Kim, Su-Hye;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.4
    • /
    • pp.51-56
    • /
    • 2022
  • Purpose: By applying an ultrasonic mechanical device to the liquid fertilizer storage in the pig dropping treatment plant, the initial odor of the odor source is reduced, and the air dilution drainage of the complex odor is fundamentally recognized to facilitate odor treatment on the mechanical and chemical biological treatment devices at the rear. Research design, data and methodology: The odor concentration on the site boundary was measured to confirm the state of reduction. In order to prevent the spread of odor from the collection of the pig dropping treatment plant, it was measured by installing an ultrasonic generator inside the installation wall after installing the sealing wall. Results: The average value of the March and April measurement data remained close to neutral at 8.2 after 8.6 treatment before pH treatment, decreased 97.3% from 462 mg/L before SS treatment to 10.5 mg/L after treatment, and the composite odor was reduced by 85% from 20 to 3 before treatment. It was confirmed that ammonia (NH3) was reduced by 99% from 5.8 ppm to 0.09 ppm, and general bacteria were also reduced by 99% from 3,200 CFU/mL to 57 CFU/mL Conclusion: Applying the ultrasonic air ejector hybrid system and zigzag air complex module development product to resource circulation centers or sewage treatment facilities is thought to reduce inconvenience to residents due to odors caused.

TREATMENT OF MIDFACE DEFICIENCY ON ADULT CLEFT LIP AND PALATE INDIVIDUALS BY DISTRACTION OSTEOGENESIS : CASE REPORT (골신연술에 의한 성인 구순구개열자의 중안면함몰의 개선: 증례보고)

  • Son, Woo-Sung;Kang, Sang-Wook;Kang, Dae-Geun;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Maxillary deficiency, anterior cross bite, constriction of maxillary arch, malaligned teeth are frequently observed in patients with cleft lip and palate. Surgery and orthodontics, combined intervention are needed to correct maxillary deficiency. Distraction osteogenesis that currently used has many advantages like less relapse tendency, more advancement of maxilla, capable in growing patients. In case 1, 18 years old girl with BCLP had severe midfacial deficiency and multiple missing of teeth. LeFort I osteotomy, followed by maxillary distraction osteogenesis utilizing rigid external distraction device(RED) system, was performed. After a 6-day latency period, distraction proceeded at a rate of 1mm per day (at 1st week, 1.5mm/day). Total advancement was 19mm. The RED device left in place for the additional 4 weeks for consolidation. After the RED device was removed, face mask was applied with elastic traction for 5 weeks. After achieving acceptable facial appearance and occlusion, orthodontic appliance was removed. The results after 4 years follow-up was sustained pretty well without aggravation of velopharyngeal function. In case 2, 22 years old man with UCLP had severe midfacial deficiency and palatally erupted upper 2nd premolars due to arch length discrepancy, but the anterior segment of maxillary did not show constriction and crowding. patient had no arch width discrepancy, crowding was concentrated on premolar region. Segmental LeFort I osteotomy was performed. After a 6 - day latency period, using internal distraction device, distraction proceeded at a 0.5mm per day(at 1st week, 0.75 - 1 mm/day). Total advancement was 15mm. After internal distraction device was removed, face mask was applied with elastic traction for 4 weeks. After surgical-orthodontic treatment, facial appearance and occlusion was improved pretty good, and after 46 months follow-up the result was retained well.

A study on the treatment of muscle pain using a high-frequency pain treatment device (고주파 통증치료기를 이용한 근육통 치료에 대한 연구)

  • Jae-Hyun Jo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.3
    • /
    • pp.152-160
    • /
    • 2023
  • After the recent COVID-19 outbreak, more and more people are paying attention to health care. Many people feel uncomfortable in life due to muscle pain after sports or exercise as a hobby and often take a break from exercise. After exercising for a long time or exercising excessively, pain appears throughout the body within 24 to 48 hours after exercise. This pain is called delayed onset muscle soreness (DOMS). In this study, the effectiveness of the pain relief of delayed onset myalgia was verified by using a high-frequency pain therapy device that generates deep heat. EMG was measured before and after pain treatment at ordinary times, RMS values were obtained through analysis, statistical analysis was performed using the SPSS program, and it was judged to be statistically significant. In addition, statistical analysis of the RMS value between normal and after pain treatment was conducted to confirm that there was no significance, and to confirm how much it returned to normal after pain treatment. In addition, since the standards for pain are different for each person even if the size of the same pain is the same, the NRS questionnaire for the size of pain was conducted, and the size of pain felt by the subjects was analyzed using the SPSS program and statistical significance was obtained. Therefore, as a result of this study, the high-frequency pain therapy device generated deep heat in the pain area to raise the temperature, and expanded the arteries and capillaries to increase blood flow, thereby increasing blood circulation and metabolism, and alleviating the pain of delayed onset muscle pain.

Maxillomandibular advancement surgery after long-term use of a mandibular advancement device in a post-adolescent patient with obstructive sleep apnea

  • Lee, Keun-Ha;Kim, Kyung-A;Kwon, Yong-Dae;Kim, Sung-Wan;Kim, Su-Jung
    • The korean journal of orthodontics
    • /
    • v.49 no.4
    • /
    • pp.265-276
    • /
    • 2019
  • Patients with obstructive sleep apnea (OSA) whose phenotype belongs to a craniofacial vulnerability are referred from sleep doctors to orthodontists. In adults, for osseo-pharyngeal reconstruction (OPR) treatment, permanent maxillomandibular advancement (MMA) surgery and use of a temporary mandibular advancement device (MAD) are applied. This case report demonstrates successful treatment of OSA through application of phased MAD and MMA in a 16-year-old male with craniofacial deformity and residual growth potential. This patient showed skeletal and dentoalveolar changes after 7-year MAD use throughout post-adolescence, which affected the design and timing of subsequent MMA surgery, as well as post-surgical orthodontic strategy. This case report suggests that OPR treatment can be useful for treatment of OSA in post-adolescent patients, from an orthodontic point of view, in close collaboration with sleep doctors for interdisciplinary diagnosis and treatment.

Emission and heat recovery characteristics of heat recovery and combustor-type CO2 generator for greenhouses (온실용 축열 연소기형 이산화탄소 발생기의 배기 및 열회수 특성)

  • Choi, Byungchul;Lee, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.52-59
    • /
    • 2014
  • The purpose of this study is to evaluate the performance of after-treatment equipment and thermal storage devices for a heat recovery and combustor-type $CO_2$ generator fuelled a kerosene. To reduce the levels of harmful exhaust gases produced by a $CO_2$ generator, a catalyzed particulate filter(CPF) has been selected as an after-treatment device, by considering back pressure and exhaust gas temperature. The CO conversions of the catalyzed SiC filter(full plugging) were 92%, and the concentration of PM(particulate matter) was near ambient. A thermal recovery device was used to recover 13% of the heat energy from the exhaust gas through heat exchangers installed on the exhaust line of the $CO_2$ generator. 69% of the moisture within the exhaust gases was removed by condensing water, in order to minimize excessive humidity within the greenhouse.