• 제목/요약/키워드: After treatment system

검색결과 3,632건 처리시간 0.03초

RECOVERY OF METALS FROM EAF DUST WITH RAPID SYSTEM

  • Shin, Hyoung-ky;Moon, Seok-min;Jhung, Sung-sil
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.381-386
    • /
    • 2001
  • The dust generated from the electric arc furnace steel making process is classified as hazardous material by Korean Environmental Protection Acts, mainly because of the existence of water teachable Pb, Zn and Cd. Thus the treatment of EAF dust is being carried out to fulfill both the environmental aspect and recovery of valuable metals. To establish the proper process for recovering the valuable metals (Fe, Zn, Pb and Cd) and producing the non-toxic slag from EAF dust, using RAPID-10 system, feasibility study have been carried out. To find out the scale-up factor for designing the commercial scale EAF dust treatment process(capacity 50,000 ton EAF dust per year) entitled RAPID-50 system. The design and construction of RAPID-50 (RIST Arc Plasma Industrial Device) system for treating 50,000 ton of EAF dust per year is now undergoing. Overall plan for treating EAF dust generated in KOREA will be setup after successful operation (December, 2002) of RAPID-50 system.

  • PDF

Analysis of Treatment Response in Patients with Oral Lichen Planus

  • Ju, Hye-Min;Kim, Kyung-Hee;Jeon, Hye-Mi;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • 제46권2호
    • /
    • pp.41-48
    • /
    • 2021
  • Purpose: To evaluate compliance by analyzing and comparing treatment duration, degree of improvement after treatment and treatment response of oral lichen planus (OLP) patients according to characteristics of them and the severity of the lesion. Methods: According to treatment process, 132 subjects with OLP who first visited the Department of Oral Medicine at the Pusan National University Dental Hospital from January 2017 to December 2020were classified into three groups: Treatment completed (CT) group, Under treatment (UT) group, and Dropped out during follow-up (DT) group. The reticulation/keratosis, erythema, and ulceration (REU) scoring system was used to assess the severity of OLP. The degree of improvement after treatment was evaluated in CT group. Results: There were 53 (40.15%) CT, 27 (20.45%) UT and 52 (39.39%) DT. In CT group, according to initial REU score there was a statistical difference in the degree of improvement, but not in the length of time to complete treatment. There was no statistical difference between the days it took for patients to feel symptom relief, and the days of entire treatment among three groups. However, there was a positive correlation between the REU score of gingiva and duration of treatment in DT group. In the CT and DT groups, there was a correlation between the length of time taken to relieve symptoms and the duration of treatment. Conclusions: The severity of the gingival lesion and the initial response to treatment have a large effect on the entire treatment period and prognosis, so it should be considered when explaining the disease prognosis and treatment period to patients, and the clinician needs to focus on initial symptom relief.

Colistimethate 분무요법 시행 환자에서 투여 전후 신기능의 변화 (Changes in Renal Function by Nebulized Colistimethate Treatment)

  • 안혜진;정유진;김재송;김수현;손은선
    • 한국임상약학회지
    • /
    • 제27권2호
    • /
    • pp.92-98
    • /
    • 2017
  • Background: Nebulized colistimethate is increasingly used, because there are problems such as renal dysfunction and low distribution within the lungs when colistimethate is administered intravenously. This study was designed to compare and analyze the changes in renal function by of nebulized colistimethate treatment for its safe administration. Methods: This study retrospectively reviewed the electronic medical records of adult patients above 19 years old, receiving only the nebulized colistimethate at least 4 days in Yonsei university health system from Nov 2014 to Aug 2015. Acute kidney injury (AKI) was determined by using the RIFLE criteria (Risk, Injury, Failure, Loss and End-stage renal disease) according to serum creatinine (SCr) levels before and after use of nebulized colistimethate. Results: 48 patients were included our study and their SCr increased significantly after nebulized colistimethate treatment ($SCr_0$ vs. $SCr_1$; $0.85{\pm}0.80$ vs. $1.00{\pm}0.82mg/dL$, n=48, p<0.001), but the changes were in normal range according to the standards at Yonsei university health $system^a$. Among 48 patients, 38 patients were in the non-AKI group (79.2%), and 10 patients developed AKI (20.8%). Within the AKI group, 2 patients were in the Injury group (20%) and the other 8 in the Risk group (80%). Conclusion: There was no significant difference in age, dosage and duration of treatment between AKI group and non-AKI group (p>0.05). The study has a significance in that it reviewed the safety of nebulized colistimethate only treatment to national patients, analyzing its nephrotoxicity. It has confirmed that nebulized colistimethate is a safer method than intravenous injection, and requires to establish a guideline for the use of nebulized colistimethate in further studies with broader patient groups. $^a$ : SCr Male 0.68-1.19 mg/dL, Female 0.49-0.91 mg/dL.

만성기침에 대한 보조제제로써 청인(淸咽)트로키 복합투여의 임상적 유효성 평가 (Clinical Effects of Chungin-troche As an Adjuctive Medicine with Chronic Cough Patients)

  • 노영래;최준용;이성헌;김재환;정희재;정승기
    • 대한한방내과학회지
    • /
    • 제29권3호
    • /
    • pp.716-729
    • /
    • 2008
  • Objectives : We designed this study to evaluate the effectiveness of Chungin-troche(CIT) preparation as an adjunctive medicine to a herbal extract of Chungsangboha-tanggagambang(CSBH). Methods : A paralled, comparative study of CSBH+CIT and CSBH was conducted on 42 patients of chronic cough who attended Division of Allergy, Immune & Respiratory System, Department of Internal Medicine, College of Oriental Medicine, Kyung Hee University between December, 2007 and June, 2008. The treatment in each group lasted for two weeks. Patients were asked to fill in the Leicester Cough Questionnaire (LCQ) before and after administration of each treatment legimen. Results : 42 patients completed the trial and no adverse effects were reported. Both CSBH +CIT group and CSBH group showed statistical significant improvement in total LCQ score after 2 weeks from baseline. Social domain score and total score in patients taking CSBH+CIT showed a statistical significant increase compared to those scores in CSBH patients. Conclusion : CSBH+CIT compositive preparation and CSBH separate preparation appeared to have some benefits in the treatment of chronic cough. However, additional CIT preparation to CSBH can improve social domain in LCQ of chronic cough patients.

  • PDF

불완전 분류식 하수처리구역의 강우에 의한 하수도시설의 침입수/유입수 영향 분석 (Effect of infiltration/inflow by rainfall for sewerage facilities in the area with partially separate sewer system)

  • 신정섭;한상원;육준수;이춘구;강선홍
    • 상하수도학회지
    • /
    • 제33권3호
    • /
    • pp.177-190
    • /
    • 2019
  • The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.

A Modified eCura System to Stratify the Risk of Lymph Node Metastasis in Undifferentiated-Type Early Gastric Cancer After Endoscopic Resection

  • Hyo-Joon Yang ;Hyuk Lee;Tae Jun Kim;Da Hyun Jung;Kee Don Choi;Ji Yong Ahn;Wan Sik Lee;Seong Woo Jeon;Jie-Hyun Kim;Gwang Ha Kim;Jae Myung Park;Sang Gyun Kim;Woon Geon Shin;Young-Il Kim;Il Ju Choi
    • Journal of Gastric Cancer
    • /
    • 제24권2호
    • /
    • pp.172-184
    • /
    • 2024
  • Purpose: The original eCura system was designed to stratify the risk of lymph node metastasis (LNM) after endoscopic resection (ER) in patients with early gastric cancer (EGC). We assessed the effectiveness of a modified eCura system for reflecting the characteristics of undifferentiated-type (UD)-EGC. Materials and Methods: Six hundred thirty-four patients who underwent non-curative ER for UD-EGC and received either additional surgery (radical surgery group; n=270) or no further treatment (no additional treatment group; n=364) from 18 institutions between 2005 and 2015 were retrospectively included in this study. The eCuraU system assigned 1 point each for tumors >20 mm in size, ulceration, positive vertical margin, and submucosal invasion <500 ㎛; 2 points for submucosal invasion ≥500 ㎛; and 3 points for lymphovascular invasion. Results: LNM rates in the radical surgery group were 1.1%, 5.4%, and 13.3% for the low-(0-1 point), intermediate- (2-3 points), and high-risk (4-8 points), respectively (P-fortrend<0.001). The eCuraU system showed a significantly higher probability of identifying patients with LNM as high-risk than the eCura system (66.7% vs. 22.2%; McNemar P<0.001). In the no additional treatment group, overall survival (93.4%, 87.2%, and 67.6% at 5 years) and cancer-specific survival (99.6%, 98.9%, and 92.9% at 5 years) differed significantly among the low-, intermediate-, and high-risk categories, respectively (both P<0.001). In the high-risk category, surgery outperformed no treatment in terms of overall mortality (hazard ratio, 3.26; P=0.015). Conclusions: The eCuraU system stratified the risk of LNM in patients with UD-EGC after ER. It is strongly recommended that high-risk patients undergo additional surgery.

고온 호기성 산화 시스템의 슬러지로부터 펠렛 비료의 생산과 Chinese cabbage의 생육 및 토양 특성에 대한 영향 (Production of Pellet Fertilizer from the Sludge of Thermophilic Aerobic Oxidation System End Its Effects on the Growth of Chinese cabbage and Soil Properties)

  • 이원일;;이명규
    • 한국축산시설환경학회지
    • /
    • 제10권2호
    • /
    • pp.101-110
    • /
    • 2004
  • 고온호기성발효장치(TAO system)로 발효 처리한 양돈분뇨고형물을 톱밥과 왕겨로 혼합한 뒤 성형건조장치를 이용하여 펠렛 비료를 제조하였다. 제조된 펠렛 비료(TAO-PF)의 비료이용성을 검토하기 위하여 배추를 이용하여 포장시험을 실시하였으며, 수확 후 생육량 및 토양의 생물, 이화학적 변화를 분석하였다. 생육실험은 펠렛 비료(TAO-PF)를 포함하여 시판 상토(Bed soil), 발효고형물(TAO-S), 화학비료(NPK), 무비료(대조구)로 나누어 실험하였다. 제조된 발효펠렛(TAO-PF)의 상온저장성은 미생물의 증식경향으로 보아 수분 함량이 $18\%,\;25\%$ 처리구보다는 $12\%$ 처리구가 적절한 것으로 판단되었다. 배추를 이용한 각 처리구에서의 생육실험결과, 토양세균의 변화는 TAO-PF 처리구가 NPK, 무비료구 보다 처리기간중 증식하는 경향을 보였으며, 특히 방선균의 증가와 사상균의 감소현상은 NPK, 무비료 처리 에 비해 TAO-S, TAO-PF 처리구에서 현저하여 발효고형물의 토양시비가 토양생물상 변화에 매우 효과적인 것으로 나타났다. 본 생육실험을 통해 배추의 구고, 구폭, 엽수 등으로 보아 TAO-S, TAO-PF 처리구는 각각 화학비료, 시판상토 처리구를 대체 할 수 있을 것으로 판단된다.

  • PDF

술후 방사선 치료 후 재발한 후두 육종양 암종 (Sarcomatoid Carcinoma) 1예 (A Case of Recurred Sarcomatoid Carcinoma of Larynx after Postoperative Radiotherapy)

  • 정준희;임범진;;최홍식
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.236-239
    • /
    • 2010
  • Sarcomatoid carcinoma is a rare carcinoma which arises from upper respiratoy system, gastrointestinal tract, urinary tract and skin. Sarcomatoid carcinoma of larynx is rare so pathogenesis, clinical behavior, treatment and prognosis of it is being debated. Treatment of sarcomatoid carcinoma of larynx is similar to squamous cell carcinoma of larynx. We report a case of recurred sarcomatoid carcinoma after surgical treatment and postoperative radiotherapy.

다이아몬드막의 광전도성에 관한 수소 플라즈마 표면 처리의 효과 (Effect of Hydrogen Plasma Treatment on the Photoconductivity of Free-standing Diamond Film)

  • Sung-Hoon, Kim
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1999년도 PROCEEDINGS OF 99 INTERNATIONAL CONFERENCE OF THE KACG AND 6TH KOREA·JAPAN EMG SYMPOSIUM (ELECTRONIC MATERIALS GROWTH SYMPOSIUM), HANYANG UNIVERSITY, SEOUL, 06월 09일 JUNE 1999
    • /
    • pp.337-350
    • /
    • 1999
  • Thick diamond film having ~700${\mu}{\textrm}{m}$ thickness was deposited on polycrystalline molybdenum (Mo) substrate using high power (4kW) microwave plasma enhanced chemical vapor deposition (MPECVD) system. We could achieve free-standing diamond film via detaching as-deposited diamond film from the substrate by rapid cooling them under vacuum. We investigated the variation of photoconductivity after exposing the film surface to either oxygen or hydrogen plasma. At as-grown state, the growth side (the as-grown surface of the film) showed noticeable photoconductivity. The oxygen plasma treatment of this side led to the insulator. After exposing the film surface to hydrogen plasma, on the other hand, we could observe the reappearing of photoconductivity at the growth side. Based on these results, we suggest that the hydrogen plasma treatment may enhance the photoconductivity of free-standing diamond film.

  • PDF

Effect of hydrogen plasma treatment on the photoconductivity of free-standing diamond film

  • Kim, Sung-Hoon
    • 한국결정성장학회지
    • /
    • 제9권4호
    • /
    • pp.441-445
    • /
    • 1999
  • Thick diamond film having $~700\mu\textrm{m}$ thickness was deposited on polycrystalline molybdenum(Mo) substrate using high power (4 kW) microwave plasma-enhanced chemical vapor depostion (MPECVD) system. We could achieve free-standing diamond film via detaching as-deposited diamond film from the substrate by rapid cooling them under vacuum. We investigated the variation of photoconductivity after exposing the film surface to either oxygen or hydrogen plasma. At as-grown state, the growth side (the as-grown surface of the film) showed noticeable photoconcuctivity. The oxygen plasma treatment of this side led to the insulator. After exposing the film surface to hydrogen plasma, on the other hand, we could observe the reappearing of photoconductivity at the growth side. Based on these results, we suggest that the hydrogen plasma treatment may enhance the photoconductivity of free-standing diamond film.

  • PDF