• Title/Summary/Keyword: Aerosol size distribution

Search Result 206, Processing Time 0.021 seconds

Analysis of Aerosol Optical Properties in Seoul Using Skyradiometer Observation (스카이라디오미터 관측을 통한 서울 상공 에어러솔의 광학적 특성 분석)

  • Koo, Ja-Ho;Kim, Jhoon;Kim, Mi-Jin;Cho, Hi Ku;Aoki, Kazuma;Yamano, Maki
    • Atmosphere
    • /
    • v.17 no.4
    • /
    • pp.407-420
    • /
    • 2007
  • Optical characteristics of aerosols in Seoul are investigated from the measurements of sky radiance by Skyradiometer at Yonsei University from December 2005 to November 2006. Aerosol optical depth (AOD) shows a maximum in June due to weak ventilation and particle growth by aging process and hygroscopic effect. Single scattering albedo (SSA) and Angstrom Exponent (AE) show the lowest value in spring due to the Asian dust. It is clear that coarse mode is dominant in spring and fine mode is dominant in summer from the volume size distribution measured in this study. The explanations on the changes of aerosol loadings are provided through the correlation between AOD and AE, while the pattern of wavelength dependency related to particle size is shown through the correlation between SSA and AE. Backward trajectory analysis by HYSPLIT provides information about origin of aerosol, which allows us to classify the case according to the source region and the path distance. Although the direction of backward trajectory traces back mostly to west, coarse mode particle is dominant in the case of long pathway and fine mode particle is dominant in the case of short pathway. This discrepancy is caused by the regional difference of emitted particles.

Aerosol Wall Loss in Teflon Film Chambers Filled with Ambient Air

  • Lee Seung-Bok;Bae Gwi-Nam;Moon Kil-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E1
    • /
    • pp.35-41
    • /
    • 2004
  • Aerosol wall loss is an important factor affecting smog chamber experiments, especially with chambers made of Teflon film. In this work, the aerosol wall loss was investigated in 2.5 and $5.8-m^3$ cubic-shaped Teflon film chambers filled with ambient air. The natural change in the particle size distribution was measured using a scanning mobility particle sizer in a dark environment. The rate of aerosol wall loss was obtained from the deposition theory suggested by Crump and Seinfeld (1981). The measured rates of aero-sol wall loss were In a good agreement with the theoretical and experimental values given by McMurry and Rader (1985), implying that the electrostatic effect enhances particle deposition on the chamber wall. The significance of aerosol wall loss correction was demonstrated with the photochemical reaction experiments using the ambient air.

Collection Efficiency of Electrostatic Precipitator using Moment Method (모멘트 방법을 이용한 전기집진기의 집진 효율)

  • 정창훈;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.345-353
    • /
    • 2002
  • A study of polydispersed aerosol dynamics by Electrostatic Precipitator (ESP) was carried out. The log-normal particle size distribution was assumed and moment method was considered. In order to apply moment method in Deutsch-Anderson equation, Cunningham slip correction factor and Cochet's charge equation were simplified for certain range of particle size. The three parameters, which explain the particle size distribution, such as total number concentration, geometric mean diameter, and geometric standard deviation were considered to derive the analytic solution. The obtained solution was compared with available numerical results (Bai et al., 1995). The comparison of the numerical and analytic results showed a good agreement.

Condensational Growth of Fine Aerosol Particles to Increase Precipitation Efficiency (집진효율 향상을 위한 미세 에어로졸 입자의 응축에 의한 성장 연구)

  • Han, Sang-Woo;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1069-1076
    • /
    • 2000
  • As the environmental problems grow, the regulation of the pollutants emitted from power plants increases. Most of the pollutants in particle phase are removed by particle removal facilities, but fine particles between 0.1 micron and I micron in diameter have a low removal efficiency compared to particles in other size ranges. Therefore the present concern has concentrated on the removal of those fine particles. The purpose of this study is to grow fine particles by condensation to the range larger than I micron. Theoretically the general dynamic equation is solved with an assumption that the particle size follows a log-normal distribution to calculate the temporal behavior of the size distribution. Experiments have been carried out to compare the results with the theoretical predictions. Particles grown by condensation are sampled by impactors and observed with SEM photographs.

Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경)

  • Jeung Jae Yeal;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

The Fluctuations of Aerosol Number Concentration in the leodo Ocean Research Station (이어도 해양종합과학기지에서의 에어로솔 수 농도 변동)

  • Park, Seong-Hwa;Lee, Dong-In;Seo, Kil-Jong;You, Cheol-Hwan;Jang, Min;Kang, Mi-Yeong;Jang, Sang-Min;Kim, Dong-Chul;Choi, Chang-Sup;Lee, Byung-Gul
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.721-733
    • /
    • 2009
  • To examine the fluctuations of aerosol number concentration with different size in the boundary layer of marine area during summer season, aerosol particles were assayed in the Ieodo Ocean Research Station, which is located 419 km southwest of Marado, the southernmost island of Korea, from 24 June to 4 July, 2008. The Laser Particle Counter (LPC) was used to measure the size of aerosol particles and NCEP/NCAR reanalysis data and sounding data were used to analyze the synoptic condition. The distribution of aerosol number concentration had a large variation from bigger particles more than 3 ${\mu}m$ in diameter to smaller particles more than 1 ${\mu}m$ in diameter with wind direction during precipitation. The aerosol number concentration decreased with increasing temperature. An increase (decrease) of small size of aerosol (0.3${\sim}$0.5 ${\mu}m$ in diameter) number concentration was induced by convergence (divergence) of the wind fields. The aerosol number concentration of bigger size more than 3 ${\mu}m$ in diameter after precipitation was removed as much as 89${\sim}$94% compared with aerosol number concentration before precipitation. It is considered that the larger aerosol particles would be more efficient for scavenging at marine boundary layer. In addition, the aerosol number concentration with divergence and convergence could be related with the occurrence and mechanism of aerosol in marine boundary layer.

Characteristic of Size-Resolved Water-Soluble Organic Carbon in Atmospheric Aerosol Particles Observed during Daytime and Nighttime in an Urban Area (도시지역 낮.밤 대기에어로졸의 입경 별 수용성 유기탄소의 특성)

  • Park, Seung Shik;Shin, Dong Myung
    • Particle and aerosol research
    • /
    • v.9 no.1
    • /
    • pp.7-21
    • /
    • 2013
  • Twelve-hour size-resolved atmospheric aerosols were measured to determine size distributions of water-soluble organic carbon(WSOC) during daytime and nighttime, and to investigate sources and formation pathways of WSOC in individual particle size classes. Mass, WSOC, ${NO_3}^-$, $K^+$, and $Cl^-$ at day and night showed mostly bimodal size distributions, peaking at the size range of $0.32-0.55{\mu}m$(condensation mode) and $3.1-6.2{\mu}m$(coarse mode), respectively, with a predominant condensation mode and a minor coarse mode. While ${NH_4}^+$ and ${SO_4}^{2-}$ showed unimodal size distributions which peaked between 0.32 and $0.55{\mu}m$. WSOC was enriched into nuclei mode particles(< $0.1{\mu}m$) based on the WSOC-to-mass and WSOC-to-water soluble species ratios. The sources and formation mechanisms of WSOC were inferred in reference to the size distribution characteristics of inorganic species(${SO_4}^{2-}$, ${NO_3}^-$, $K^+$, $Ca^{2+}$, $Na^+$, and $Cl^-$) and carbon monoxide. Nuclei mode WSOC was likely associated with primary combustion sources during daytime and nighttime. Among significant sources contributing to the condensation mode WSOC were homogeneous gas-phase oxidation of VOCs, primary combustion emissions, and fresh(or slightly aged) biomass burning aerosols. The droplet mode WSOC could be attributed to aqueous oxidation of VOCs in clouds, cloud-processed biomass burning aerosols, and small contributions from primary combustion sources. From the correlations between WSOC and soil-related particles, and between WSOC and sea-salt particles, it is suggested that the coarse mode WSOC during daytime is likely to condense on the soil-related particles($K^+$ and $Ca^{2+}$), while the WSOC in the coarse fraction during nighttime is likely associated with the sea-salt particles($Na^+$).

Analysis of Vertical Profiles and Optical Characteristics of the Asian Dust Using Ground-based Measurements (지상관측장비를 이용하여 관측한 봄철 황사의 연직분포와 광학적 특성 분석)

  • Lee, Byung-Il;Yoon, Soon-Chang;Kim, Yoonjae
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.287-297
    • /
    • 2008
  • The vertical profiles and optical properties of Asian dust are investigated using ground-based measurements from 1998 to 2002. Vertical profiles of aerosol extinction coefficient are evaluated using MPL (Micro Pulse Lidar) data. Optical parameters such as aerosol optical thickness ($\tau$), ${\AA}ngstr\ddot{o}m$ exponent ($\alpha$), single scattering albedo ($\omega$), refractive index, and volume size distribution are analyzed with sun/sky radiometer data for the same period. We can separate aerosol vertical profiles into three categories. First category named as 'Asian dust case', which aerosol extinction coefficient is larger than $0.15km^{-1}$ and dust layer exists from surface up to 3-4km. Second category named as 'Elevated aerosol case', which aerosol layer exists between 2 and 6km with 1-2.5km thickness, and extinction coefficient is smaller than $0.15km^{-1}$. Third category named as 'Clear sky case', which aerosol extinction coefficient appears smaller than $0.15km^{-1}$. and shows that diurnal variation of background aerosol in urban area. While optical parameters for first category indicate that $\tau$ and $\alpha$ are $0.63{\pm}0.14$, $0.48{\pm}0.19$, respectively. Also, aerosol volume concentration is increased for range of 1 and $4{\mu}m$, in coarse mode. Optical parameters for second category can be separated into two different types. Optical properties of first type are very close to Asian dust cases. Also, dust reports of source region and backward trajectory analyses assure that these type is much related with Asian dust event. However, optical properties of the other type are similar to those of urban aerosol. For clear sky case, $\tau$ is relatively smaller and $\alpha$ is larger compare with other cases. Each case shows distinct characteristics in aerosol optical parameters.

Characteristics of the dry deposition fluxes and ambient particl size distributions of PCBs: The measurements on fall, 1999 (입자상 PCBs 건식침적량과 입경분포 특성: 1999년 가을 측정)

  • Shin, Hye Jung;Kim, Yong Pyo;Yi, Seung Muk
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.179-188
    • /
    • 2009
  • The dry deposition fluxes of particulate polychlorinated biphenyls (PCBs) were measured along with their mass size distributions at Seoul and Incheon in fall in 1999. The dry deposition fluxes of PCBs were in the range of $16.7{\sim}62.2ng/m^2/day$. The ambient concentrations of particulate PCBs were in the range of 0.07 to $0.20ng/m^3$. Generally, the mass size distribution of particulate PCBs shows bi-modal distribution. The mass fraction of PCBs in the fine particle fraction ($D_p<2.1 {\mu}m$) was over than 55% of the total PCBs concentrations. It was found that Seoul and Incheon were not the major source of PCBs emissions in Korea. Based on the comparison with the measurement data in summer, 1999, it is likely that both the dry deposition fluxes and ambient particulate PCBs concentrations were not site-specific.

  • PDF

An Experimental Study on the Characteristics of Direct Photoelectric Charging (직접 광대전의 대전특성에 관한 실험적 연구)

  • Lee, Chang-Sun;Kim, Yong-Jin;Kim, Sang-Sao
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.753-759
    • /
    • 2000
  • Photoelectric charging is a very efficient way of charging small particles. This method can be applied to combustion measurement, electrostatic precipitator, metal separation and control of micro-contamination. To understand the photoelectric charging mechanism, particle charging of silver by exposure to ultraviolet is investigated in this study. Average charges and charge distributions are measured at various conditions, using two differential mobility analyzers, a condensation nucleus counter, and an aerosol electrometer. The silver particles are generated in a spark discharge aerosol generator. After that process, the generated particles are charged in the photoelectric charger using low-pressure mercury lamp that emits ultraviolet having wavelength 253.7 nm. The results show that ultra-fine particles are highly charged by the photoelectric charging. The average charges linearly increase with increasing particle size and the charge distribution change with particle size. These results are discussed by comparison with previous experiments and proposed equations. It is assumed that the coefficient of electron emission probability is affected by initial charge. The results also show that the charge distribution of a particle is dependent on initial charge. Single changed particle, uncharged particle and neutralized particle are compared. The differences of charge distribution in each case increase with increasing particle size.