• Title/Summary/Keyword: Aerosol size distribution

Search Result 206, Processing Time 0.022 seconds

Seasonal variation in size distributions for ionic components in the atmospheric aerosol (대기중 입자상물질에 있어서 이온성분의 입도별 계절변동)

  • 김희강;조기철;이주희;최민규;마창진;강충민;여현구
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.55-61
    • /
    • 1996
  • Measurements of the seasonal variations of concentration and size distribution of TSP, $SO_4^{2-}, NO_3^-, Cl^-, NH_4^+, Na^+, K^+, Ca^{2+}$ and $Mg^{2+}$ were made by Andersen air sampler from May 1995 to April 1996 in Seoul. The size distribution of these ions was divided into four patterns. 1) Distribution was concentrated on fine particles over a year such as $NO_3^-$ component, 2) Distribution was predominated in coarse particles fraction over a year such as $Mg^{2+}$ and $Ca^{2+}$ components, 3) Distribution was differerent from various seasons such as $NH_4^+, SO_4^{2-}, Cl^-$ and $K^+$ components, 4) Distribution was bi-modal such as $Na^+$.

  • PDF

The Variation of Aerosol Number Concentrations in Relation with 3D Wind Components in the Ieodo Ocean Research Station (이어도 해양종합과학기지에서의 3차원 바람성분에 따른 에어로솔 수 농도 변동 특성)

  • Park, Sung-Hwa;Jang, Sang-Min;Lee, Dong-In;Jung, Woon-Seon;Jeong, Jong-Hoon;Jung, Sung-A;Jung, Chang Hoon;Kim, Kyungsik;Kim, Kyung-Eak
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.97-107
    • /
    • 2012
  • To investigate variation of aerosol number concentration at each different size with three-dimensional (3D) wind components in ocean area, aerosol particles and 3D wind components were measured in the Ieodo Ocean Research Station, which is located to 419 km southwest from Marado, the southernmost island of Korea, from 25 June to 8 July 2010. The Laser Particle Counter (LPC) and ultrasonic anemometer were used to measure the size of aerosol particles and 3D wind components (zonal (u), meridional (v), and vertical (w) wind) respectively. Surface weather chart, NCEP/NCAR reanalysis data and sounding data were used to analyze the synoptic condition. The distribution of aerosol number concentration had a large variation from bigger particles more than 1.0 ${\mu}m$ in diameter by wind direction during precipitation. In the number concentration of aerosol particles with respect to the weather conditions, particles larger than 1.0 ${\mu}m$ in size were decreased and sustained to the similar concentration at smaller particles during precipitation. The increase in aerosol number concentration was due to the sea-salt particles which was suspended by southwesterly and upward winds. In addition, the aerosol number concentration with vertical wind flow could be related with the occurrence and increasing mechanism of aerosol in marine boundary layer.

Elemental components analysis according to the size of fine particles emitted from a coal-fired power plant using an ejector-porous tube dilution sampling and ELPI (이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석)

  • Shin, Dongho;Park, Daehoon;Joe, Yunhui;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.69-77
    • /
    • 2022
  • In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 ㎛. The highest number concentration was about 0.01 ㎛. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 ㎛ was shown. For the components of PM1.0 (particles less than 1 ㎛), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 ㎛), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.

Experimental Analysis on Particle Growth m TEOS/O2 Plasma Reactor (TEOS/O2 플라즈마 반응기에서 미립자 성장에 대한 실험적 분석)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.149-153
    • /
    • 2001
  • A study on the particle growth in $TEOS/O_2$ plasma was performed, and particle size and its distribution was measured by the electrical aerosol analyzer (EAA), light scattering particle size analyzer and the particle size was also determined by SEM. The effects of process variables such as total gas flow rate, reactor pressure, supplied power and initial reactant concentration on the particle growth were investigated. From the EAA results, the particle size distribution is divided into three groups of the cluster size and the small and large size particles. The particle size distribution measured by the light scattering particle size analyzer becomes bimodal, because the cluster size particles smaller than 20 nm in diameter cannot be detected by the light scattering particle size analyzer. The size of particles measured by the light scattering particle size analyzer is in good agreements with those by the SEM. Also we could understand that the particle formation is very sensitive to the changes of reactor pressure and reactant concentration. As the total gas flow rate increases, the particle size decreases because of the shorter residence time. As the reactor pressure, or the reactant concentration increases, the particle concentration increases and the particles grow more quickly by the faster coagulation between particles.

  • PDF

Preliminary analyses on decontamination factors during pool scrubbing with bubble size distributions obtained from EPRI experiments

  • Lee, Yoonhee;Cho, Yong Jin;Ryu, Inchul
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.509-521
    • /
    • 2021
  • In this paper, from a review of the size distribution of the bubbles during pool scrubbing obtained from experiments by EPRI, we apply the bubble size distributions to analyses on the decontamination factors of pool scrubbing via I-COSTA (In-Containment Source Term Analysis). We perform sensitivity studies of the bubble size on the various mechanisms of deposition of aerosol particles in pool scrubbing. We also perform sensitivity studies on the size distributions of the bubbles depending on the diameters at the nozzle exit, the molecular weights of non-condensable gases in the carrier gases, and the steam fractions of the carrier gases. We then perform analyses of LACE-ESPANA experiments and compare the numerical ~ results to those from SPARC-90 and experimental results in order to show the effect of the bubble size distributions.

Generation of Nano/Submicron Particles Using an Electrically Heated Tube Furnace (전기가열 튜브로를 이용한 나노/서브마이크론 입자의 발생)

  • Ji, Jun-Ho;Pae, Yang-Il;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1734-1743
    • /
    • 2003
  • Aerosol generator using an electrically heated tube furnace is a stable apparatus to supply nanometer sized aerosols by using the evaporation and condensation processes. Using this method, we can generate highly concentrated polydisperse aerosols with relatively narrow size distribution. In this work, characteristics of particle size distribution, generated from a tube furnace, were experimentally investigated. We evaluated effects of several operation parameters on particle generation: temperature in the tube furnace, air flow rates through the tube, size of boat containing solid sodium chloride(NaCl). As the temperature increased, the geometric mean diameter increased and the total number concentration also increased. Dilution with air affected the size distribution of the particles due to coagulation. A smaller sized boat, which has small surface area to contact with air, brings smaller particles of narrow size distribution in comparison of that of a larger boat. Finally, we changed the electrical mobility diameter of aggregate sodium chloride particles by varying relative humidity of dilution air, and obtained non-aggregate sodium chloride particles, which are easy to generate exact monodisperse particles.

Performance Evaluation of Gas Cleaning Industrial Filters using a Bi-Modal Test Aerosol for Dust Loading Studies

  • Lee, Jae-Keun;Kim, Seong-Chan;Benjamin Y.H. Liu
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.131-137
    • /
    • 1996
  • Typical size distribution of emission particulates is bi-modal in shape with particles in the fine mode (< 2.0 $\mu\textrm{m}$) and the coarse mode. An experimental study of pressure drop across the industrial gas cleaning filters has been conducted using particle mixture of fine alumina and coarse Arizona dusts with a rotating aerosol disperser to generate the bi-modal test aerosol. Pressure drop increased linearly with increasing mass loading. The pressure drop was found to be strongly dependent upon the mass ratio of fine to coarse particles. The smaller the mass ratio of fine to coarse particles and the higher face velocity are, the faster pressure drop rises. The fine particles and the greater inertia of the particle moving fast would cause a denser cake formation on the filter surface, resulting in a greater specific resistance to the gas flow.

  • PDF

Analysis of Gravitational Coagulation of Aerosol Particles (중력 침강에 의한 입자 응집의 해석적 연구)

  • Jin, Hyeong-A;Jeong, Chang-Hun;Lee, Gyu-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.303-312
    • /
    • 1998
  • To obtain the solution to the time-dependent particle size distribution of an aerosol undergoing gravitational coagulation, the moment method was used which converts the non linear integro-differential equation to a set of ordinary differential equations. A semi-numerical solution was obtained using this method. Subsequently, an analytic solution was given by approximating the collision kernel into a form suitable for the analysis. The results show that during gravitational coagulation, the geometric standard deviation increases and the geometric mean radius decreases as time increases.

  • PDF

Optimization of Cutting Fluids for Environmentally Conscious Machining (환경친화적 기계가공을 위한 절삭유 최적화에 관한 연구)

  • Hwang, Jun;Jung, Eui-Sik;Liang, Steven Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.948-951
    • /
    • 2000
  • This paper presents the analytical and experimental methodology for the prediction of aerosol concentration and size distribution due to cutting fluid atomization mechanism in turnining operation. The established analytical model which is based on atomization theory analyzes the cutting fluid motion and aerosol generation in machining process. The impinging and evaporation experiments were performed to know the particle size and evaporation rate of cutting fluid. The predictive models can be used as a basis for environmental impact analysis on the shop floor. It can be also facilitate the optimization of cutting fluid usage in achieving a balanced consideration of productivity and environmental consciousness.

  • PDF

Intercomparison of Number Concentrations by CPCs using Generated Particles in Chamber (챔버 내 발생 입자를 이용한 CPC 수농도 비교 평가)

  • Bae, Min-Suk;Park, Da-Jeong;Park, Seung-Shik;Chen, Wei-Nai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.619-630
    • /
    • 2014
  • Two butanol-based Condensation Particle Counters (CPC 3022, CPC 3025), three water-based CPCs (CPC3781, CPC3785${\times}$2), a Gardner Counter, a Fast Mobility Particle Sizer (FMPS), and an Aerosol Electrometer (AE) were deployed to measure the number concentrations from atomized aerosol under six different conditions. Comparisons of particle number concentrations measured by the CPCs, FMPS, and AE were conducted to evaluate the performance of the each CPCs using laboratory generated artificial particles such as NaCl, succinic acid ($C_4H_6O_4$), and particles generated by propane torch & heat gun in the chamber. Good correlation between the CPC3025 and FMPS was observed for the total particle number concentrations in the size range 15 nm to 90 nm. In addition, this paper suggests that photometric mode in water-based CPC3785 could not be used as quantitative of number concentrations for CPC3785.