• Title/Summary/Keyword: Aerosol penetration

Search Result 22, Processing Time 0.016 seconds

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

Characteristics of Indoor Particulate Matter Concentrations by Size at an Apartment House During Dusty-Day (황사 발생시 아파트 실내에서 미세먼지 크기별 농도 특성)

  • Joo, Sang-Woo;Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • It is recommended for the public to stay at home and to close the doors and windows when a high-particulate-matter environment such as a yellow sand event occurs outside. However, there are lack of empirical studies describing how much outdoor PM infiltrates into a closed house and how much indoor PM an inhabitant is exposed to during the period. In this study, the $PM_{10}$ and $PM_{2.5}$ were measured at the kitchen in an apartment house by an optical particle counter for 3 days including a yellow sand event. The outdoor PMs and the outdoor wind speeds were referred from surrounding weather stations. We analyzed the penetration of $PM_{10-2.5}$ and $PM_{2.5}$ at the test house against the outdoor wind speed supposed corresponding to the change of air exchange rate. In addition, the effect of an indoor activity on change in the indoor PM was investigated. In result, the indoor $PM_{10-2.5}$ was very low even a yellow sand event occurred outside; rather, a contribution of indoor activities to increase in $PM_{10-2.5}$ was higher. In contrast, the indoor $PM_{2.5}$ fluctuated following the outdoor $PM_{2.5}$ trend at high wind speeds or remained almost constant at low wind speed.