• Title/Summary/Keyword: Aerogenerator

Search Result 5, Processing Time 0.021 seconds

Reliability Evaluation of Thruster Break for Aerogenerator (풍력발전기용 쓰러스터 브레이크의 신뢰성 평가)

  • Jung, Dong Soo
    • Journal of Applied Reliability
    • /
    • v.13 no.3
    • /
    • pp.165-174
    • /
    • 2013
  • Thruster break for aerogenerator performs a role that is stopping the rotor in case of emergency such as strong wind, system abnormality or maintenance check. In this study, failure analysis and test evaluation on the thruster break for aerogenerator are proposed, and the entire process to improve reliability of the product through design improvement is presented. The typical failure case is fatigue and wear, and failure cause on these are identified and improvement plan is presented. Lastly, reliability improvement is established to analyse test results before after the life test.

A Study on Design of 50kW PMSG for Micro-grid Application (마이크로그리드용 50kW급 PMSG 설계에 관한 연구)

  • Jeong, Moon-Seon;Moon, Chae-Joo;Kim, Hyoung-Gil;Chang, Young-Hak;Park, Tae-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.4
    • /
    • pp.527-536
    • /
    • 2014
  • In this paper, the 50kW aerogenerator which is applicable to the microgrid was designed and analyzed by using commercial simulation program Maxwell 2D. Particularly, the suggested PMSG to reduce the cogging torque introduced the offset and skew concept. The suggested optimal value of offset and skew was decided by 2mm and 60 degree of electric angle. The simulation results of the PMSG when load operation condition showed the average harmonic distortion 1.3%, voltage 322.41V, current 94.95A, and iron loss 9.73W, eddy current loss 73.68W, copper loss 3.52kW. The capacity of aerogenerator calculated 61.56kW, and the suggested design process can be applied to higher capacity generator.

Study about the Design of Special Blade and Simulation for Wind Generation system (풍력발전 시스템의 특수 블레이드 설계 및 시뮬레이션에 관한 연구)

  • Yoon, Jeong-Phil;Lee, Gi-Je;Yoon, Hyung-Sang;Yoon, Seok-Am;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.192-195
    • /
    • 2004
  • Into investment expense that wind generation system that is one of clean energy is less than existent energy in narrow shipfitter maximum effect to source of energy that have Eoteulsu evaluate. There is shortcoming that Blade structure of existent aerogenerator faces at problem of safety accident in overpopulated area and noise and have additional expense of supply of electric power equipment. In this paper, We wish to supplement problem that is such through design of special Blade structure that have noise reduction and stability. Wish to achieve design and simulation of blade to use CATIA for this, and analyze adaptedness of system.

  • PDF

A Study on the Applcation of Small Wind Power System using Meteorological Simulation Data in Pusan (기상수치모의 자료를 이용한 부산지역의 소형풍력발전 시스템 적용에 관한 연구)

  • Lee, KwiOk;Lee, KangYeol;Kang, Dongbae;Park, Changhyoun;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1085-1093
    • /
    • 2014
  • We investigate the amount of potential electricity energy generated by wind power in Busan metropolitan area, using the mesoscale meteorological model WRF (Weather Research & Forecasting), combined with small wind power generators. The WRF modeling has successfully simulated meteorological characteristics over the urban areas, and showed statistical significant to predict the amount of wind energy generation. The highest amount of wind power energy has been predicted at the coastal area, followed by at riverbank and upland, depending on predicted spatial distributions of wind speed. The electricity energy prediction method in this study is expected to be used for plans of wind farm constructions or the power supplies.

Developement of Electrical Load Testing System Implemented with Power Regenerative Function (회생전력 기능을 갖는 전기부하시험장치 개발)

  • Do, Wang-Lok;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 2016
  • The electrical load testing system developed from this study was designed to control rated-capacity-testing or variable-load-testing in an active and precise manner and save electric energy during testing, and also to convert the saved electric energy through the electrical load testing system to grid line. As for the device under testing, it was designed to be applied to not only transformer, rectifier, voltage regulator, inverter which require grid voltage source but, also applied to electric power, aerogenerator, photovoltaic, hybrid generator, battery, etc. which do not require grid voltage source. The system was designed to return the power consumed during the testing to the grid line by connecting the synchronizing pwm inverter circuit to the grid voltage source, and was also made to enable the being-tested system from disuse of approximately 93.4% energy when compared to the conventional load testing system which has used the passive resistor.